SAFETY PRECAUTIONS

(Read these precautions before using this product.)
Before using the MELSEC-L series products, please read this manual and the relevant manuals carefully and pay full attention to safety to handle the product correctly. When equipment is used by the way a maker doesn't designate, the protection of the equipment may be damaged. In this manual, the safety precautions are classified into two levels: " WARNING" and " CAUTION".
WARNING
CAUTION
Under some circumstances, failure to observe the precautions given under " CAUTION" may lead to serious consequences. Observe the precautions of both levels because they are important for personal and system safety. Make sure that the end users read this manual and then keep the manual in a safe place for future reference. All safety precautions for the MELSEC-L series products are described in this manual.
Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous conditions, resulting in minor or moderate injury or property damage.
[Design Precautions]
WARNING
Configure safety circuits external to the programmable controller to ensure that the entire system operates safely even when a fault occurs in the external power supply or the programmable controller. Incorrect output or malfunction due to a communication failure may result in an accident. (1) Emergency stop circuits, protection circuits, and protective interlock
circuits for conflicting operations such as forward/reverse rotations or upper/lower limit positioning must be configured external to the programmable controller.
1
[Design Precautions]
WARNING
(2) Machine OPR (Original Point Return) of the CPU module’s positioning
function is controlled with two kinds of data: an OPR direction and an OPR speed. Deceleration starts when the near-point watchdog signal turns on. If an incorrect OPR direction is set, motion control may continue without deceleration. To prevent machine damage caused by this, configure an interlock circuit external to the programmable controller.
(3) When the CPU module detects an error during operation of the CPU
module’s positioning function, the motion slows down and stops.
(4) When the programmable controller detects an abnormal condition, it stops
the operation and the output status is as follows:
• If the overcurrent or overvoltage protection of the power supply module is activated, all outputs are turned off.
• If the self-diagnostics function of the CPU module detects an error such as a watchdog timer error, all outputs are held unchanged or turned off according to the parameter setting.
All outputs may turn on if an error occurs in a part, such as an I/O control part, where the CPU module cannot detect any error. To ensure safety operation in such a case, provide a safety mechanism or a fail-safe circuit external to the programmable controller. For a fail-safe circuit example, refer to "GENERAL SAFETY REQUIREMENTS" in this manual.
(5) Outputs may remain on or off due to a failure of an output circuit relay or
transistor. Configure an external circuit for monitoring output signals that could cause a serious accident.
In an output circuit, when a load current exceeding the rated current or an overcurrent caused by a load short-circuit flows for a long time, it may cause smoke and fire. To prevent this, configure an external safety circuit, such as a fuse.
Configure a circuit so that the programmable controller is turned on first and then the external power supply. If the external power supply is turned on first, an accident may occur due to an incorrect output or malfunction.
Configure a circuit so that the external power supply is turned off first and then the programmable controller. If the programmable controller is turned off first, an accident may occur due to an incorrect output or malfunction.
2
[Design Precautions]
WARNING
For the operating status of each station after a communication failure, refer to relevant manuals for the network. Failure to do so may result in an accident due to an incorrect output or malfunction.
When changing data of a running programmable controller from a peripheral connected to the CPU module or from an external device such as a personal computer connected to an intelligent function module, configure an interlock circuit in the program to ensure that the entire system will always operate safely. For other controls to a running programmable controller (such as program modification or operating status change), read relevant manuals carefully and ensure the safety before the operation. Especially, in the case of a control from an external device to a remote programmable controller, immediate action cannot be taken for a problem on the programmable controller due to a communication failure. To prevent this, configure an interlock circuit in the program, and determine corrective actions to be taken between the external device and CPU module in case of a communication failure.
An absolute position return by the CPU module’s positioning function may turn off the servo-on signal (servo off) for approximately 20ms, and the motor may run unexpectedly. If this causes a problem, provide an electromagnetic brake separately to lock the motor during absolute position return.
Do not write any data to the "system area" or "write-protect area" (R) of the buffer memory in an intelligent function module. Also, do not turn on any “use prohibited” signal that is output from the CPU module to the intelligent function module. Doing so may cause malfunction of the programmable controller system.
When setting auto refresh parameters, specify "Y" for the remote output RY refresh devices. Specifying any other than "Y" (for example, M or L) will hold the previous device status in the case of a CPU stop. For information on how to stop the data link, refer to the MELSEC-L CC-Link System Master/Local Module User's Manual.
Disconnection of a communication cable (such as a CC-Link dedicated cable) may make the line condition unstable, causing communication errors on multiple stations on the network. Configure an interlock circuit in the program so that the system will operate safely even if these communication errors occur on multiple stations. Failure to do so may result in an accident due to an incorrect output or malfunction.
3
[Design Precautions]
WARNING
Precautions for using digital-analog converter modules and analog input/output modules
When a module is faulty, analog outputs may remain on. Configure an external circuit for monitoring output signals that could cause a serious accident.
Precautions for using high-speed counter modules and flexible high-speed I/O control modules
Outputs may remain on or off due to a failure of a transistor for external output. Configure an external circuit for monitoring output signals that could cause a serious accident.
Precautions for using positioning modules
Configure safety circuits external to the programmable controller to ensure that the entire system operates safely even when a fault occurs in the external power supply or the programmable controller. Incorrect output or malfunction due to a communication failure may result in an accident. (1) Machine OPR (Original Point Return) is controlled by two kinds of data: an
OPR direction and an OPR speed. Deceleration starts when the near-point watchdog signal turns on. If an incorrect OPR direction is set, motion control may continue without deceleration. To prevent machine damage caused by this, configure an interlock circuit external to the programmable controller.
(2) When the module detects an error, the motion slows down and stops or the
motion suddenly stops, depending on the stop group setting in parameter. Set the parameter according to the positioning system specifications. In addition, set the OPR parameter and positioning data within the parameter setting range.
(3) Outputs may remain on or off, or be undefined due to a failure of a
component such as an insulated element or transistor in an output circuit, where the CPU module cannot detect any error. Configure an external circuit for monitoring output signals in a system where an incorrect output could cause a serious accident.
An absolute position restoration by the positioning function may turn off the servo-on signal (servo off) for approximately 60ms + scan time, and the motor may run unexpectedly. If this causes a problem, provide an electromagnetic brake to lock the motor during absolute position restoration.
4
[Design Precautions]
WARNING
Precautions for using flexible high-speed I/O control modules
When changing setting data and operating status of the running module from a personal computer, configure an interlock circuit external to the programmable controller to ensure that the entire system operates safely. In addition, before performing online operations for the running module from a personal computer, determine corrective actions to be taken in case of a communication failure due to poor contact of cables.
[Design Precautions]
CAUTION
Do not install the control lines or communication cables together with the main circuit lines or power cables. Keep a distance of 100mm or more between them. Failure to do so may result in malfunction due to noise.
During control of an inductive load such as a lamp, heater, or solenoid valve, a large current (approximately ten times greater than normal) may flow when the output is turned from off to on. Therefore, use a module that has a sufficient current rating.
Time from when the CPU module is powered on or is reset to when it enters in RUN status depends on the system configuration, parameter settings, and program size. Design the program so that the entire system will always operate safely, regardless of the time.
Precautions for using dual channel isolated high resolution analog-digital converter modules
Do not install the analog signal cable together with main circuit lines, power cables, or load circuit lines of a device other than the programmable controller. Install the analog output cable 150mm away from the above lines and cables. Failure to do so may result in malfunction due to noise.
5
[Design Precautions]
CAUTION
Precautions for using digital-analog converter modules and analog input/output modules
At power-on, a voltage may occur or a current may flow between output terminals for a moment. In this case, start the control after analog outputs become stable.
Power on or off the external power supply while the programmable controller is on. Failure to do so may result in incorrect output or malfunction.
Precautions for using flexible high-speed I/O control modules
Do not install the control lines or communication cables together with the main circuit lines or power cables. Keep a distance of 150mm or more between them. Failure to do so may result in malfunction due to noise.
[Installation Precautions]
WARNING
Shut off the external power supply for the system in all phases before mounting or removing the module. Failure to do so may result in electric shock or cause the module to fail or malfunction.
6
[Installation Precautions]
CAUTION
Use the programmable controller in an environment that meets the general specifications described in this manual. Failure to do so may result in electric shock, fire, malfunction, or damage to or deterioration of the product.
To interconnect modules, engage the respective connectors and securely lock the module joint levers until they click. Incorrect interconnection may cause malfunction, failure, or drop of the module.
Do not directly touch any conductive part of the module. Doing so can cause malfunction or failure of the module.
Securely connect an extension cable to the connectors of a branch module and an extension module. After connection, check that the cable is inserted completely. Poor contact may cause malfunction.
Securely install the SD memory card pushing the card into the SD memory card installation slot. After installation, check that the SD memory card is installed completely. Poor contact may cause malfunction.
Keep in mind that there is a possibility that the unit is high temperature, during turning on electricity and immediately after power supply interception.
Do not directly touch any conductive part and electronic components of the module and the SD memory card. Doing so can cause malfunction and failure of the module and the SD memory card.
[Wiring Precautions]
WARNING
Shut off the external power supply for the system in all phases before wiring. Failure to do so may result in electric shock or cause the module to fail or malfunction.
After installation and wiring, attach the included terminal cover to the product before turning it on for operation. Failure to do so may result in electric shock.
Precautions for using flexible high-speed I/O control modules
When connecting a differential output terminal to the differential receiver of a drive unit, connect a high-speed output common terminal to the common terminal of the differential receiver of the drive unit. Failure to do so may cause the module to fail or malfunction because of the potential difference that occurs between the high-speed output common terminal and the differential receiver common terminal.
7
[Wiring Precautions]
CAUTION
Ground the FG and LG terminals to the protective ground conductor dedicated to the programmable controller. Failure to do so may result in electric shock or malfunction.
Use applicable solderless terminals and tighten them within the specified torque range. If any spade solderless terminal is used, it may be disconnected when a screw on the terminal block comes loose, resulting in failure.
Check the rated voltage and terminal layout before wiring to the module, and connect the cables correctly. Connecting a power supply with a different voltage rating or incorrect wiring may cause a fire or failure.
Connectors for external device connection must be crimped or pressed with the tool specified by the manufacturer, or must be correctly soldered. Incomplete connections could result in short circuit, fire, or malfunction.
Connect the connector to the module securely.
Do not install the control lines or communication cables together with the main
circuit lines or power cables. Keep a distance of 100mm or more between them. Failure to do so may result in malfunction due to noise.
Place the cables in a duct or clamp them. If not, dangling cables may swing or inadvertently be pulled, resulting in damage to the module or cables or malfunction due to poor connection.
Confirm the interface type in advance and connect the cable correctly. Connecting a cable to a different interface or incorrect wiring will cause failure of the module and the external device.
Tighten the screws on the terminal block within the specified torque range. Undertightening can cause short circuit or malfunction. Overtightening can damage the screw and/or module, resulting in drop, short circuit, fire, or malfunction.
When disconnecting the cable from the module, do not pull the cable by the cable part. For a cable with connector, hold the connector by hand and pull it out. For a cable connected to a terminal block, loosen the terminal block screws first before removing the cable. Failure to do so may result in malfunction and damage to the module or cable.
Prevent foreign matter such as dust or wire chips from entering the module. Such foreign matter can cause a fire, failure, or malfunction.
8
[Wiring Precautions]
CAUTION
A protective film is attached to the top of the module to prevent foreign matter, such as wire chips, from entering the module during wiring. Do not remove the film during wiring. Remove it for heat dissipation before system operation.
For the CC-Link system, use dedicated cables that are specified by the manufacturer. If any other cable is used, performance of the CC-Link system is not guaranteed. Also, the maximum overall cable length and the station-to­station cable length must meet those specified in the MELSEC-L CC-Link System Master/Local Module User’s Manual. If not, normal data communication is not guaranteed.
To use the high-speed counter function of the CPU module, ground the shielded cable to the encoder (relay box). Failure to do so may cause malfunction.
Mitsubishi Electric programmable controllers must be installed in control panels. Connect the main power supply to the power supply module in the control panel through a relay terminal block. Wiring and replacement of a power supply module must be performed by qualified maintenance personnel who is familiar with protection against electric shock. For wiring methods, refer to the MELSEC-L CPU Module User's Manual (Hardware Design, Maintenance and Inspection).
Precautions for using high-speed counter modules
Ground the shield cable on the encoder side (relay box). Always ground the FG and LG terminals to the protective ground conductor. Failure to do so may cause malfunction.
Precautions for using CC-Link/LT master module
For the CC-Link/LT, use the cables specified by the CC-Link Partner Association. The performance of the CC-Link/LT cannot be assured if any other cables than the specified are used. For the network wiring, follow the specifications described in MELSEC-L CC-Link/LT Master Module User's Manual. Normal data communication is not guaranteed if the wiring is not conducted according to the specifications.
9
[Startup and Maintenance Precautions]
WARNING
Do not touch any terminal while power is on. Doing so will cause electric shock or malfunction.
Correctly connect the battery connector. Do not charge, disassemble, heat, short-circuit, solder, or throw the battery into the fire. Also, do not expose the battery to liquid or strong shock. Doing so will cause the battery to produce heat, explode, ignite, or leak, resulting in injury and fire.
Shut off the external power supply for the system in all phases before cleaning the module or retightening the screws on the terminal block or connector screws. Failure to do so may result in electric shock.
[Startup and Maintenance Precautions]
CAUTION
Before performing online operations (especially, program modification, forced output, and operation status change) for a running CPU module from the peripheral connected, read relevant manuals carefully and ensure the safety. Improper operation may damage machines or cause accidents.
Do not disassemble or modify the modules. Doing so may cause failure, malfunction, injury, or a fire.
Use any radio communication device such as a cellular phone or PHS (Personal Handy-phone System) more than 25cm away in all directions from the programmable controller. Failure to do so may cause malfunction.
Shut off the external power supply for the system in all phases before connecting or disconnecting the module. Failure to do so may cause the module to fail or malfunction.
Tighten the screws on the terminal block or connector screws within the specified torque range. Undertightening can cause drop of parts or wires, short circuit, or malfunction. Overtightening can damage the screw and/or module, resulting in drop, short circuit, or malfunction.
After the first use of the module (including a display unit), the number of module connections/disconnections is limited to 50 times. Exceeding the limit (in accordance with IEC 61131-2) may cause malfunction.
After the first use of the product, the number of SD memory card insertions/removals is limited to 500 times. Exceeding the limit may cause malfunction.
10
[Startup and Maintenance Precautions]
CAUTION
Do not drop or apply shock to the battery to be installed in the module. Doing so may damage the battery, causing the battery fluid to leak inside the battery. If the battery is dropped or any shock is applied to it, dispose of it without using.
Before handling the module, touch a conducting object such as a grounded metal to discharge the static electricity from the human body. Failure to do so may cause the module to fail or malfunction.
Before testing the CPU module's positioning function, set a low speed value for the speed limit parameter so that the operation can be stopped immediately upon occurrence of a hazardous condition.
Use a soft dry cloth to clean dirt off of the module.
Precautions for using positioning modules
Before testing the operation, set a low speed value for the speed limit parameter so that the operation can be stopped immediately upon occurrence of a hazardous condition.
Precautions for using flexible high-speed I/O control modules
Before performing online operations for the running module from the personal computer connected, read relevant manuals carefully and ensure the safety.
Before changing each setting of the module, read relevant manuals carefully and ensure the safety, and change the status of the CPU module to STOP.
[Operation Precautions]
CAUTION
When controlling a running programmable controller (especially, changing data, program modification, and operation status change) from an external device such as a personal computer connected to an intelligent function module, read the relevant user's manual carefully and ensure the safety before the operation. Incorrect data change, program modification, and status control may cause malfunction of the system, mechanical damage, or accidents.
While set values in the buffer memory are being registered to the flash ROM in the module, do not turn off the power to the module and do not reset the CPU module. Doing so will affect the flash ROM data, and setting to the buffer memory and registration to the flash ROM need to be performed again. Also, it may cause failure or malfunction of the module.
11
[Disposal Precautions]
CAUTION
When disposing of this product, treat it as industrial waste. When disposing of batteries, separate them from other wastes according to the local regulations. (For details of the Battery Directive in EU member states, refer to the MELSEC-L CPU Module User's Manual (Hardware Design, Maintenance and Inspection).)
[Transportation Precautions]
CAUTION
When transporting lithium batteries, follow the transportation regulations. (For details of the regulated models, refer to the MELSEC-L CPU Module User's Manual (Hardware Design, Maintenance and Inspection).)
12
PRÉCAUTIONS DE SÉCURITÉ
(Lire ces précautions avant toute utilisation du produit.)
Avant d'utiliser les produits de la série MELSEC-L, lire attentivement ce manuel et les autres manuels correspondants en prêtant une attention particulière à ce qui a trait à la sécurité du produit. Lorsque l’équipement est utilisé d’une manière non prévue par le fabricant, la protection de l’équipement peut être endommagée. Dans ce manuel, les précautions de sécurité sont classées en deux niveaux, à savoir : " AVERTISSEMENT" et " ATTENTION"
AVERTISSEMENT
ATTENTION
Dans certaines circonstances, le non-respect d'une précaution de sécurité introduite sous le titre " ATTENTION"peut avoir des conséquences graves. Les précautions de ces deux niveaux doivent être observées dans leur intégralité car elles ont trait à la sécurité des personnes et aussi du système. Veiller à ce que les utilisateurs finaux lisent ce manuel qui doit être conservé soigneusement à portée de main pour s'y référer autant que de besoin. Toutes les précautions de sécurité à observer pour les produits de la série MELSEC-L sont présentées dans ce manuel.
Attire l'attention sur le fait qu'une négligence peut créer une situation de danger avec risque de mort ou de blessures graves.
Attire l'attention sur le fait qu'une négligence peut créer une situation de danger avec risque de blessures légères ou de gravité moyennes ou risque de dégâts matériels.
[Précautions lors de la conception]
AVERTISSEMENT
Configurer des circuits de sécurité extérieurs à l'automate programmable pour garantir la sécurité du système dans son ensemble à la survenance d'une anomalie dans l'alimentation externe comme dans l'automate programmable. Une sortie erronée ou un dysfonctionnement suite à une erreur de communication peuvent être à l'origine d'un accident. (1) Les circuits d'arrêt d'urgence, les circuits de protection et les circuits de
verrouillage de sécurité pour les opérations contradictoires du genre rotation avant/arrière ou positionnement en limite haute/basse doivent être configurés à l'extérieur de l'automate programmable.
13
[Précautions lors de la conception]
AVERTISSEMENT
(2) L'OPR machine (retour au point origine) de la fonction de positionnement
du module CPU se commande par deux sortes de données : sens vers OPR et vitesse vers OPR. La décélération commence à l'apparition du signal de surveillance d'approche. Si l'indication du sens vers l'OPR est erronée, la commande de mouvement continue sans décélération. Pour éviter l'endommage de la machine dans une telle éventualité, constiuer un circuit de verrouillage extérieur à l'automate programmable.
(3) Si le module CPU détecte une erreur pendant l'exécution d'une fonction
de positionnement par module CPU, le mouvement est décéléré jusqu'à l'arrêt.
(4) Lorsque l'automate programmable détecte une situation anormale, il
interrompt la marche et l'état des sorties est comme indiqué ci-après.
• Au déclenchement d'une protection contre surintensité ou surtension dans le module d'alimentation, toutes les sorties sont mises hors service.
• Si la fonction d'auto-diagnostic du module CPU détecte une erreur telle qu'une erreur d'horloge de surveillance, toutes les sorties peuvent être maintenues sans changement ou mises hors service par le paramétrage.
Toutes les sorties pourraient rester actives si l'erreur s'est produite dans une partie comme un organe d'entrée/sortie dont le module CPU ne peut pas détecter les erreurs. Pour garantir la sécurité en exploitation dans un telle éventualité, il faut donc prévoir un mécanisme de sécurité ou un circuit de mise en sécurité à l'extérieur de l'automate programmable. On trouvera un exemple de circuit de mise en sécurité à la rubrique "EXIGENCES GÉNÉRALES DU POINT DE VUE DE LA SÉCURITÉ" du présent manuel.
(5) Après défaillance d'un relais ou d'un transistor de circuit de sortie, les
sorties peuvent restées à l'état actif ou inactif. Configurer un circuit de surveillance externe pour le suivi des signaux de sortie susceptibles de provoquer un accident grave.
Dans un circuit de sortie, si le courant de charge excède la valeur nominale ou si une surintensité causée par un court-circuit à la charge persiste longtemps, il peut en résulter un dégagement de fumée avec départ de feu. Pour éviter cela, il faut configurer un circuit de sécurité, avec un fusible par exemple.
Configurer le circuit de façon à allumer d'abord l'automate programmable avant l'alimentation externe. Si on commence par brancher l'alimentation externe, ceci peut être une cause d'accident en cas de sortie incorrecte ou autre dysfonctionnement.
14
[Précautions lors de la conception]
AVERTISSEMENT
Configurer un circuit qui coupera d'abord l'alimentation externe puis l'automate programmable. Si c'est l'automate programmable qui est mis hors tension en premier, il y a risque d'accident en cas de sortie erronée ou autre dysfonctionnement.
Quant à l'état opérationnel de chacune des stations en cas de problème de communication, voir les manuels correspondants pour le réseau. Faute de quoi, une instruction de sortie incorrecte ou un dysfonctionnement pourrait être à l'origine d'un accident.
Pour pouvoir procéder à des changements de données sur un automate programmable en marche à partir d'un périphérique connecté au module CPU ou à partir d'un ordinateur individuel connecté à un module fonctionnel intelligent, prévoir dans le programme un circuit de verrouillage permettant d'assurer en touts temps la sécurité de l'ensemble du système. Pour les autres interventions sur un automate programmable en marche (comme par exemple une modification de programme de la station maître ou un changement d'état fonctionnel), procéder comme indiqué dans les manuels correspondants et faire les contrôles de sécurité avant d'opérer. En particulier, lorsqu'un automate programmable distant est commandé à partir d'un dispositif externe, il faut tenir compte du fait qu'aucune action immédiate ne sera possible s'il y a un problème de communication avec l'automate programmable. Pour éviter cela, constituer un circuit de verrouillage dans le programme, et déterminer quelles seront les mesures correctives à prendre en cas de problème de communication entre le dispositif externe et le module CPU.
Le retour en position absolue par la fonction de positionnement du module CPU peut entraîner une suspension du signal servo (servo off) d'une durée de l'ordre de 20ms pendant lesquelles le moteur pourrait se mettre en marche inopinément. Si cela pose problème, prévoir un frein électromagnétique pour bloquer le moteur pendant le retour en position absolue.
N'introduire aucune donnée dans les zones réservées "system area" ou "write-protect area" (R) de la mémoire-tampon d'un module fonctionnel intelligent. En outre, comme signal de sortie du module CPU vers le module fonctionnel intelligent, il ne faut utiliser aucun des signaux dont l'usage est interdit ("use prohibited"). Faute de quoi, il y aura des dysfonctionnements dans le système de l'automate programmable.
15
[Précautions lors de la conception]
AVERTISSEMENT
Au paramétrage de la réactualisation automatique, sélectionner le dispositif "Y" comme dispositifs de réactualisation (RY) de sortie distante. Si on sélectionne un dispositif autre que "Y" (comme M ou L), le module CPU maintient l'état antérieur du dispositif lors des arrêts CPU. À propros de l'interruption de la liaison de données, voir le Manuel de l'utilisateur des modules maître/local du système MELSEC-L CC-Link.
Le débranchement d'un câble de communication (comme un câble dédié CC­Link) peut rendre la ligne instable et entraîner des erreurs de communications dans de multiples stations du réseau. Constituer un circuit de verrouillage dans le programme permettant de maintenir la sécurité de fonctionnement du système même en cas d'erreurs de communications sur de multiples stations. Faute de quoi, une instruction de sortie incorrecte ou un dysfonctionnement pourrait être à l'origine d'un accident.
Précautions d'utilisation des modules convertisseurs numériques-analogiques et des modules d'entrée/sortie analogiques
En as de défaillance d'un module, il se peut que les sorties analogiques restent actives. Configurer un circuit de surveillance externe pour le suivi des signaux de sortie susceptibles de provoquer un accident grave.
Précautions pour l'utilisation des modules de comptage haute vitesse et des modules de commande E/S flexibles haute vitesse
Les sorties peuvent rester en service ou hors service dans le cas d'une panne de transistor vers sortie externe. Configurer un circuit de surveillance externe pour le suivi des signaux de sortie susceptibles de provoquer un accident grave.
16
[Précautions lors de la conception]
AVERTISSEMENT
Précautions d'utilisation des modules de positionnement
Configurer des circuits de sécurité extérieurs à l'automate programmable pour garantir la sécurité du système dans son ensemble à la survenance d'une anomalie dans l'alimentation externe comme dans l'automate programmable. Une sortie erronée ou un dysfonctionnement suite à une erreur de communication peuvent être à l'origine d'un accident. (1) L'OPR machine (retour au point origine) se commande par deux sortes de
données : sens vers OPR et vitesse vers OPR. La décélération commence à l'apparition du signal de surveillance d'approche. Si l'indication du sens vers l'OPR est erronée, la commande de mouvement continue sans décélération. Pour éviter l'endommage de la machine dans une telle éventualité, constiuer un circuit de verrouillage extérieur à l'automate programmable.
(2) À la détection d'une erreur par le module CPU, l'arrêt se fera avec
décélération ou sera un arrêt brusque, selon le paramétrage du groupe des paramètres d'arrêt. Faire le paramétrage en fonction des spécifications du système de positionnement. De plus, régler les paramétrages OPR et les données de positionnement en restant à l'intérieur des plages de paramétrage possible.
(3) Les sorties peuvent rester actives ou inactives ou dans un état instable
suite à la défaillance d'un composant comme un élément isolé ou un transistor de circuit de sortie pour lequel le module CPU ne peut pas détecter les erreurs. Configurer un circuit externe pour la surveillance des signaux de sortie pour toute système dans lequel une sortie erronée pourrait avoir de graves conséquences.
Le retour en position absolue par la fonction de positionnement peut entraîner une suspension du signal servo (servo off) d'une durée de l'ordre de 60ms + temps de balayage pendant lesquelles le moteur pourrait se mettre en marche inopinément. Si cela pose problème, prévoir un frein électromagnétique pour bloquer le moteur pendant le retour en position absolue.
17
[Précautions lors de la conception]
AVERTISSEMENT
Précautions pour l'utilisation des module de commande E/S flexibles haute vitesse
Pour pouvoir changer à partir d'un ordinateur personnel le paramétrage et l'état fonctionnel du module pendant la marche, configurez un circuit de sécurité extérieur à l'automate programmable et permettant de garantir la sécurité de fonctionnement de l'ensemble du système. De plus, avant d'effectuer toute opération en ligne sur le module en marche à partir d'un ordinateur individuel, prévoir les mesures correctives à prendre dans l'éventualité d'une panne de communication par suite de mauvais contact des câbles.
18
[Précautions lors de la conception]
ATTENTION
Ne pas entremêler les lignes de commandes ou câbles de communication avec les lignes des circuits principaux ou les câbles d'alimentation. Les installer en maintenant entre eux une distance minimum de 100 mm. Faute de quoi, il y a risque de dysfonctionnement par un bruit.
À la commande d'une charge inductive comme une lampe, un réchauffeur ou une électrovanne, un fort courrant (jusqu'à 10 fois l'intensité normale) traverse la sortie quand celle-ci passe de OFF à ON. Il faut donc que le module utilisé ait une capacité de courant suffisante.
Le délai entre la mise sous tension ou la réinitialisation du module CPU et son entrée en état RUN dépend de la configuration du système, du paramétrage et de la taille du programme. Concevoir le programme de manière que tout le système fonctionne en sécurité, indépendamment de ce délai.
Précautions d'utilisation des modules convertisseurs numériques-analogiques haute résolution avec isolation et double voie
Ne pas installer le câble des signaux analogiques au voisinage de lignes du circuit principal, de câbles d'alimentation ou de lignes de circuit de charge d'un dispositif autre que l'automate programmable. Installer les câbles de sortie analogique à une distance d'au moins 150 mm des dits câbles et lignes. Faute de quoi, il y a risque de dysfonctionnement par un bruit.
Précautions d'utilisation des modules convertisseurs numériques-analogiques et des modules d'entrée/sortie analogiques
À la mise sous tension, il peut y avoir une tension ou un courant transitoire entre bornes de sortie. Dans ce cas, ne faire démarrer la régulation qu'après la stabilisation des sorties analogiques.
L'alimentation externe doit être établie et coupée avec l'automate programmable en marche. Faute de quoi, il pourrait y avoir des erronées ou d'autres dysfonctionnements.
Précautions pour l'utilisation des module de commande E/S flexibles haute vitesse
Ne pas entremêler les lignes de commandes ou câbles de communication avec les lignes des circuits principaux ou les câbles d'alimentation. Les installer en maintenant entre eux une distance minimum de 150 mm. Faute de quoi, il y a risque de dysfonctionnement par un bruit.
19
[Précautions d’installation]
AVERTISSEMENT
Couper l'alimentation externe du système sur toutes les phases avant la mise en place ou le retrait du module. Faute de quoi, il y a risque d'électrocution et le module risque de tomber en panne ou de mal fonctionner.
[Précautions d’installation]
ATTENTION
Utiliser l'automate programmable dans un environnement en conformité avec les spécifications générales que présente ce manuel. Faute de quoi, il a risque d'électrocution, de départ de feu, de dysfonctionnement, d'endommagement ou de détérioration du produit.
Pour l'interconnexion des modules, enficher les connecteurs respectifs et engager les loquets de module jusqu'à encliquètement. Une interconnexion imparfaite peut être à l'origine de dysfonctionnements, de pannes ou de chutes de modules.
Éviter tout contact direct avec les parties conductrices du module. Une manipulation incorrecte peut être à l'origine de dysfonctionnements ou de pannes du module.
Raccorder fermement une câble de rallonge aux connecteurs du sous-module et du module d'extension. Après raccordement, vérifier que le câble est bien enfiché. Tout mauvais contact peut être source de dysfonctionnements.
Introduire fermement la carte-mémoire SD en la poussant à fond dans le panier à l'emplacement pour carte-mémoire SD. Après la pose, vérifier que la carte-mémoire SD est bien en place. Un mauvais contact peut être à l'origine de dysfonctionnements.
Ne jamais oublier que la température de l'unité peut être élevée, ce qui est le cas quand elle est sous tension mais aussi lorsqu'elle vient d'être mise hors tension.
Éviter tout contact direct avec les parties conductrices et les composants électroniques du module et de la carte-mémoire SD. Cela pourrait être à l'origine de dysfonctionnements ou d'une panne du module ou de la carte­mémoire SD.
20
[Pécautions de câblage]
AVERTISSEMENT
Couper l'alimentation externe du système sur toutes les phases avant de commencer à câbler. Faute de quoi, il y a risque d'électrocution et le module risque de tomber en panne ou de mal fonctionner.
Après installation et câblage, mettre en place les couvre-bornes fournis avec le produit avant la mise sous tension et la mise en service. Faute de quoi, il y a risque d'électrocution.
Précautions pour l'utilisation des module de commande E/S flexibles haute vitesse
Pour raccorder une borne de sortie différentielle au récepteur différentiel d'une unité motrice, connecter une des bornes communes de sortie haute vitesse à la borne commune du récepteur différentiel de l'unité motrice. Faite de quoi, il y a risque de panne ou de dysfonctionnement du module en raison de la différence de potentiel entre la borne commune de sortie haute vitesse et la borne commune du récepteur différentiel.
21
[Pécautions de câblage]
ATTENTION
Mettre à la masse les bornes FG et LG sur le conducteur réservé à la protection à la terre de l'automate programmable. Faute de quoi, il y a risque d'électrocution et de dysfonctionnement.
Utiliser des bornes sans soudure de type approprié et serrer au couple de serrage prescrit. Si on utilise des bornes sans soudure de type embrochable, il y a risque de déconnexion et de panne au cas où une vis de borne se desserrerait.
Vérifier la tension nominale et l'affectation des bornes avant le câblage du module et raccorder les câbles correctement. Le raccordement d'une alimentation d'une tension autre que la tension nominale ou une erreur de câblage peut être à l'origine d'un départ de feu ou d'une panne.
Les connecteurs pour dispositifs externes doivent être sertis en utilisant l'outil prescrit par le fabricant ou, à défaut, ils seront correctement brasés. Une connexion imparfaite peut être à l'origine d'un court-circuit ou d'un départ de feu, ou entraîner des dysfonctionnements.
Enficher le connecteur fermement sur le module.
Ne pas entremêler les lignes de commandes ou câbles de communication
avec les lignes des circuits principaux ou les câbles d'alimentation. Les installer en maintenant entre eux une distance minimum de 100 mm. Faute de quoi, il y a risque de dysfonctionnement par un bruit.
Les câbles doivent être placés dans un conduit de câbles ou doivent être attachés. Faute de quoi, le ballottement ou le déplacement des câbles pourrait endommager le module ou les câbles et être à l'origine de dysfonctionnements par mauvais contact.
Vérifier au préalable le type d'interface et raccorder le câble correctement. Le raccordement d'un câble sur la mauvaise interface ou une erreur de câblage peuvent être d'une panne du module et du dispositif externe.
Serrer les vis de la plaque à bornes dans les limites des couples de serrage prescrit. Un serrage insuffisant peut être à l'origine d'un court-circuit ou de disfonctionnements. Un serrage excessif peut endommager les vis et/ou le module, avec aussi un risque de chute, de court-circuits et de dysfonctionnements.
22
[Pécautions de câblage]
ATTENTION
Pour débrancher le câble du module, ne tirer directement sur le câble proprement dit. Si le câble a un connecteur, saisir le connecteur au main et débrancher en tirant par le connecteur. Pour un câble raccordé sur une plaque à bornes, desserrer la vis de la borne. Faute de quoi, on pourrait endommager le module ou le câble et créer un risque de dysfonctionnement.
Veiller à ne pas laisser la poussière, les copeaux métalliques ou d'autres corps étrangers pénétrer dans le module. De telles corps étrangers peuvent être à l'origine d'un départ de feu, d'une panne ou d'un dysfonctionnement.
Le haut du module est recouvert d'un film protecteur pour éviter toute pénétration de corps étrangers comme des copeaux métalliques pendant le câblage du module. Ne pas retirer le film protecteur avant de terminer le câblage. Il doit cependant être retiré avant la mise en service du système pour une meilleure dispersion de la chaleur.
Pour le système CC-Link, utiliser les câbles dédiés préconisés par le fabricant. Avec tout autre type de câble, les performances ne peuvent être garanties. De plus, la longueur totale de câbles et la longueur des câbles de station à station doivent être en conformité avec les prescriptions du Manuel de l'utilisateur des modules maîtres/locaux pour système MELSEC-L CC-Link. Sinon, la communication normales des données ne peut être garantie.
Pour utiliser la fonction de comptage haute-vitesse du module CPU, mettre le câble blindé à la masse sur le décodeur (boîte à relais). Le non-respect de cette précaution expose à des dysfonctionnements.
Les automates programmable Mitsubishi Electric doivent être installés en tableau ou armoire de commande. Raccorder l'alimentation principale au module d'alimentation dans le tableau de commande sur une plaque à bornes avec relais. Le câblage et le remplacement d'un module d'alimentation doivent être effectués par un personnel de maintenance qualifié formé à la protection contre les chocs électriques. Pour la méthode de câblage, se reporter au Manuel de l'utilisateur du module CPU MELSEC-L (Conception du matériel, maintenance et inspection).
23
Loading...
+ 56 hidden pages