1. Safety Precautions ................................................................ 2
2. Parts Names ......................................................................... 3
3. Screen Configuration ............................................................ 6
4. Setting the Day of the Week and Time.................................. 6
5. Operation .............................................................................. 6
6. Timer ..................................................................................... 8
Note:
The phrase “Wired remote controller” in this operation manual refers only to the PAR-21MAA. If you need any information for the PAR-30MAA, please refer to the instruction book included in PAR-30MAA box.
7. Other Functions .................................................................. 11
8. Function Selection .............................................................. 12
9. Emergency Operation for Wireless Remote-controller (option)
.......................................................................................... 16
10. Care and Cleaning ............................................................ 16
11. Trouble Shooting ............................................................... 17
1. Safety Precautions
s Before operating the unit, make sure you read all the “Safety
precautions”.
s “Safety precautions” lists important points about safety. Please
be sure to follow them.
Symbols used in the text
Warning:
Describes precautions that should be observed to avoid the risk of injury or death to the user.
Caution:
Describes precautions that should be observed to prevent damage to the unit.
Symbols used in the illustrations
: Indicates an action that must be avoided.
: Indicates that important instructions must be followed.
: Indicates a part which must be grounded.
: Beware of electric shock. (This symbol is displayed on the main unit
label.) <Color: yellow>
Warning:
Carefully read the labels affixed to the main unit.
1) Outdoor unit Warning:
The outdoor unit must be installed on a stable, level surface, in
a place where there is no accumulation of snow, leaves or rubbish.
Do not stand on, or place any items on the unit. You may fall
down or the item may fall, causing injury.
Caution:
The outdoor unit should be installed in a location where air and noise emitted by the unit will not disturb the neighbours.
2) Indoor unit
Warning:
The indoor unit should be securely installed. If the unit is loosely mounted, it may fall, causing injury.
3) Remote controller
Warning:
The remote controller should be installed in such a way that children cannot play with it.
4) Drain hose
Caution:
Make sure that the drain hose is installed so that drainage can go ahead smoothly. Incorrect installation may result in water leakage, causing damage to furniture.
1.1.Installation
ss
s After you have read this manual, keep it and the Installation Manual
ss
in a safe place for easy reference whenever a question arises. If the unit is going to be operated by another person, make sure that this manual is given to him or her.
Warning:
The unit should not be installed by the user. Ask the dealer or an authorized company to install the unit. If the unit is installed im­properly, water leakage, electric shock or fire may result.
Use only accessories authorized by Mitsubishi Electric and ask your dealer or an authorized company to install them. If accesso­ries are installed improperly, water leakage, electric shock or fire may result.
The Installation Manual details the suggested installation method. Any structural alteration necessary for installation must comply with local building code requirements.
Never repair the unit or transfer it to another site by yourself. If repair is performed improperly, water leakage, electric shock or fire may result. If you need to have the unit repaired or moved, consult your dealer.
The appliance is not intended for use by young children or infirm persons without supervision.
Young children should be supervised to ensure that they do not play with the appliance.
5) Power line, fuse or circuit breaker
Warning:
Make sure that the unit is powered by a dedicated line. Other appliances connected to the same line could cause an overload.
Make sure that there is a main power switch.
Be sure to adhere to the unit’s voltage and fuse or circuit breaker ratings. Never use a piece of wire or a fuse with a higher rating than the one specified.
6) Grounding
Caution:
The unit must be properly grounded. Never connect the grounding wire to a gas pipe, water pipe, lightning conductor or telephone grounding wire. If the unit is not grounded properly, electric shock may result.
Check frequently that the ground wire from the outdoor unit is properly connected to both the unit’s ground terminal and the grounding electrode.
2
1. Safety Precautions
1.2. During operation
Caution:
Do not use any sharp object to push the buttons, as this may damage the remote controller.
Do not twist or tug on the remote controller cord as this may damage the remote controller and cause malfunction.
Never remove the upper case of the remote controller. It is dangerous to remove the upper case of the remote controller and touch the printed circuit boards inside. Doing so can result in fire and failure.
Never wipe the remote controller with benzene, thinner, chemical rags, etc. Doing so can result in discoloration and failure. To remove heavy stains, soak a cloth in neutral deter­gent mixed with water, wring it out thoroughly, wipe the stains off, and wipe again with a dry cloth.
Never block or cover the indoor or outdoor units intakes or outlets. Tall items of furniture underneath the indoor unit, or bulky items such as large boxes placed close to the outdoor unit will reduce the units efficiency.
Warning:
Do not splash water over the unit and do not touch the unit with wet hands. An electric shock may result.
Do not spray combustible gas close to the unit. Fire may result.
Do not place a gas heater or any other open-flame appliance
where it will be exposed to the air discharged from the unit. Incomplete combustion may result.
Warning:
Do not remove the front panel or the fan guard from the outdoor unit when it is running. You could be injured if you touch rotating, hot or high-voltage parts.
Never insert fingers, sticks etc. into the intakes or outlets, otherwise injury may result, since the fan inside the unit rotates at high speed. Exercise particular care when children are present.
If you detect odd smells, stop using the unit, turn off the power switch and consult your dealer. Otherwise, a breakdown, electric shock or fire may result.
When you notice exceptionally abnormal noise or vibration, stop operation, turn off the power switch, and contact your dealer.
Do not over-cool. The most suitable inside temperature is one that is within 5°C of the outside temperature.
Do not leave handicapped people or infants sitting or standing in the path of the airflow from the air-conditioner. This could cause health problems.
Caution:
Do not direct the airflow at plants or caged pets.
Ventilate the room frequently. If the unit is operated continu-
ously in a closed room for a long period of time, the air will become stale.
In case of failure
Warning:
Never remodel the air conditioner. Consult your dealer for any repair service. Improper repair work can result in water leakage, electric shock, fire, etc.
If the remote controller displays an error indication, the air conditioner does not run, or there is any abnormality, stop operation and contact your dealer. Leaving the unit as it is under such conditions can result in fire or failure.
If the power breaker is frequently activated, get in touch with your dealer. Leaving it as it is can result in fire or failure.
If the refrigeration gas blows out or leaks, stop the operation of the air conditioner, thoroughly ventilate the room, and contact your dealer. Leaving the unit as it is can result in accidents due to oxygen deficiency.
When the air conditioner is not to be used for a long time
If the air conditioner is not to be used for a long time due to a seasonal change, etc., run it for 4 - 5 hours with the air blowing until the inside is completely dry. Failing to do so can result in the growth of unhygienic, unhealthy mold in scattered areas throughout the room.
When it is not to be used for an extended time, keep the [power supply] turned OFF. If the power supply is kept on, several watts or several tens of watts will be wasted. Also, the accumulation of dust, etc., can result in fire.
Keep the power switched ON for more than 12 hours before starting operation. Do not turn the power supply OFF during seasons of heavy use. Doing so can result in failure.
1.3. Disposing of the unit
Warning:
When you need to dispose of the unit, consult your dealer. If pipes are removed incorrectly, refrigerant (fluorocarbon gas) may blow out and come into contact with your skin, causing injury. Releasing refrigerant into the atmosphere also damages the environment.
2. Parts Names
Indoor Unit
PEAD-RP·JAA
Fan steps 3 steps Vane – Louver – Filter Normal Filter cleaning indication
PEAD-RP·JAA
Ceiling Concealed
3
PAR-21MAA
ON/OFF
FILTER
CHECK
OPERATION
CLEAR
TEST
TEMP.
MENU
BACK DAY
MONITOR/SET
CLOCK
ON/OFF
2. Parts Names
Wired Remote-Controller (PAR-21MAA option)
Display Section
For purposes of this explanation, all parts of the display are shown as lit. During actual operation, only the relevant items will be lit.
Identifies the current operation
Shows the operating mode, etc. * Multilanguage display is sup-
ported.
Centrally Controlled indicator
Indicates that operation of the re­mote controller has been prohib­ited by a master controller.
Timer is Off indicator
Indicates that the timer is off.
Temperature Setting
Shows the target temperature.
Day-of-Week
Shows the current day of the week.
Time/Timer Display
Shows the current time, unless the simple or Auto Off timer is set. If the simple or Auto Off timer is set, shows the time remaining.
Up/Down Air Direction indica­tor
The indicator shows the direc­tion of the outcoming airflow.
One Hour Only indicator
Displayed if the airflow is set to weak and downward during COOL or DRY mode. (Operation varies according to model.) The indicator goes off after one hour, at which time the airflow di­rection also changes.
TIME SUN MON TUE WED THU FRI SAT TIMER
AFTER
ERROR CODE
˚F˚C
ONLY1Hr.
ON
Hr
OFF
AFTER
˚F˚C
FUNCTION
FILTER
WEEKLY
SIMPLE
AUTO OFF
Room Temperature display
Shows the room temperature. The room temperature display range is 8–39°C. The display flashes if the temperature is less than 8 °C or 39 °C or more.
Louver display
Indicates the action of the swing louver. Does not appear if the louver is station­ary.
(Power On indicator)
Indicates that the power is on.
Sensor indication
Displayed when the remote controller sensor is used.
Locked indicator
Indicates that remote controller but­tons have been locked.
Clean The Filter indicator
Comes on when it is time to clean the filter.
Timer indicators
The indicator comes on if the corre­sponding timer is set.
Fan Speed indicator
Shows the selected fan speed.
Ventilation indicator
Appears when the unit is running in Ventilation mode.
Operation Section
Set Temperature buttons
Down
Up
Timer Menu button (Monitor/Set button)
Mode button (Return button)
Set Time buttons
Back
Ahead
Timer On/Off button (Set Day button)
Opening the door.
Note:
“PLEASE WAIT message This message is displayed for approximately 3 minutes when power is supplied to the indoor unit or when the unit is recovering from a power failure.
Built-in temperature sensor
“NOT AVAILABLE message This message is displayed if a button is pressed to operate a function that the indoor unit does not have. If a single remote controller is used to simultaneously operate multiple indoor units that are different models, this message will not be displayed if any of the indoor units is equipped with the function.
ON/OFF button
Fan Speed button
Filter button (<Enter> button)
Test Run button
Check button (Clear button)
Airflow Up/Down button
Louver button (
Operation button)
To preceding operation number.
Ventilation button
Operation button)
(
To next operation number.
4
1
2
3
2. Parts Names
CLOCK
CHECK
RESET
SET
TEST RUN
MODE
FAN
VANE
LOUVER
min
h
AUTO START
AUTO STOP
ON/OFF
TEMP
NOT AVAILABLE
MODEL SELECT
TEST RUN
CHECK
Wireless Remote-Controller (option)
ON/OFF button
Pushing button starts operation. Pushing again stops operation.
SET TEMPERATURE button
SET TEMPERATURE button sets and any desired room tempera­ture.
FAN SPEED button
This button is used to set fan speed to low, medium or high.
MODE SELECT button
This button is used to change be­tween auto, cooling, heating and drying operation modes.
CHECK button
TEST RUN button
When using the wireless remote controller, point it towards the receiver on the indoor unit.
If the remote controller is operated within approximately two minutes after power is supplied
to the indoor unit, the indoor unit may beep twice as the unit is performing the initial auto­matic check.
The indoor unit beeps to confirm that the signal transmitted from the remote controller has been received. Signals can be received up to approximately 7 meters in a direct line from the indoor unit in an area 45° to the left and right of the unit. However, illumination such as fluorescent lights and strong light can affect the ability of the indoor unit to receive signals.
If the operation lamp near the receiver on the indoor unit is flashing, the unit needs to be inspected. Consult your dealer for service.
Handle the remote controller carefully! Do not drop the remote controller or subject it to strong shocks. In addition, do not get the remote controller wet or leave it in a location with high humidity.
To avoid misplacing the remote controller, install the holder included with the remote con­troller on a wall and be sure to always place the remote controller in the holder after use.
AUTO STOP/AUTO START button
Used for selecting timed starting or stopping.
VANE CONTROL button
Used to change the airflow direc­tion.
h button
Used for setting the current time.
min button
Used for setting the current time.
LOUVER button
Used for adjusting the airflow di­rection.
Battery installation/replacement
1. Remove the top cover, insert two AAA batter­ies, and then install the top cover.
Top cover
2. Press the Reset button.
Two AAA batteries Insert the negative (–)
end of each battery first. Install the batter­ies in the correct direc­tions (+, –)!
Press the Reset button with an object that has a narrow end.
5
AAA
AAA
CLOCK
CHECK
RESET
SET
TEST RUN
MODE
FAN
VANE
LOUVER
min
h
AUTO START
AUTO STOP
ON/OFF
TEMP
1
2
5
6
3
3
5
6
2
3. Screen Configuration
˚F˚C
TIMER
MON
OFF
WEEKLY
SUN MON TUE WED THU FRI SAT
WEEKLY
˚F˚C
˚C
TIME SUN
˚C
˚C
TIME SUN
PAR-21MAA
ON/OFF
FILTER
CHECK
OPERATION
CLEAR
TEST
TEMP.
MENU
BACK DAY
MONITOR/SET
CLOCK
ON/OFF
2
4
9
1
A
TIME SUN
2
3
4
˚C
˚C
PAR-21MAA
ON/OFF
FILTER
CHECK
OPERATION
CLEAR
TEST
TEMP.
MENU
BACK DAY
MONITOR/SET
CLOCK
ON/OFF
2
7
2
3
3
8
6 4 5
8 7
1
1 5
6
Function Selection of remote controller
ADC
Standard Control Screens
OFF ON
BC
Timer Monitor Timer Setup
B
Set Day/Time
4. Setting the Day of the Week and Time
Day of the Week & Time display
<Screen Types>
For details on setting the language for the remote controller display, refer to section 8. Function Selection. The initial language setting is English.
Function Selection of remote controller: Set the functions and ranges available to the re­mote controller (timer functions, operating restric­tions, etc.)
Set Day/Time: Set the current day of the week or time.
Standard Control Screens:
View and set the air conditioning systems oper­ating status
Timer Monitor: View the currently set timer (weekly timer, sim- ple timer, or Auto Off timer)
Timer Setup: Set the operation of any of the timers (weekly timer, simple timer, or Auto Off timer).
<How to change the screen> A :Hold down both the Mode button and the Timer On/Off button for 2
seconds.
B :Press the Timer Menu button. C :Press the Mode (Return) button. D :Press either of the Set Time buttons ( or ).
Day of the Week Setting
Time Setting
(option)
Note: The day and time will not appear if clock use has been disabled at Function Selection of remote controller.
5. Operation
(option)
Remote Controller settings Last operation mode Last set temperature Last set fan speed
Mode HEAT
COOL or DRY
FAN
Horiz. outlet Last setting Horiz. outlet
5.1. Turning ON/OFF
<To Start Operation>
Press the ON/OFF button 1.
The ON lamp 1 and the display area come on.
Note:
When the unit is restarted, initial settings are as follows.
Mode Temperature setting Fan speed
Airflow up/down
6
1. Press the or Set Time button A to show display 2.
2. Press the Timer On/Off (Set Day) button 9 to set the day.
* Each press advances the day shown at 3 : Sun Mon ... Fri
Sat.
3. Press the appropriate Set Time button A as necessary to set the time.
* As you hold the button down, the time (at 4) will increment first in
minute intervals, then in ten-minute intervals, and then in one-hour in­tervals.
4. After making the appropriate settings at Steps 2 and 3, press the Filter
button 4 to lock in the values.
(option)
Loading...
+ 14 hidden pages