MITEL SP5502FKGMPAS, SP5502SKGMPAS Datasheet

SP5502
1.3GHz I2C BUS 4-Address Synthesiser
Supersedes version in April 1994 Consumer IC Handbook, HB3120 - 2.0 DS3031 - 5.0 January 1997
The SP5502 is a single-chip frequency synthesiser designed for TV tuning systems. Control data is entered in the standard I2C BUS format. The SP5502 has four programmable I2C BUS addresses, which allows two or more synthesisers to be used in a system.
FEATURES
Complete 1·3GHz Single Chip System
Programmable via the I
Low Power Consumption (240mW Typ.)
Low Radiation
Phase Lock Detector
Varactor Drive Amp Disable
5320mA Controllable Outputs (SP5502S)
3320mA Controllable Outputs (SP5502F)
Variable I
2
C BUS Address for Multi-Tuner Applications
ESD Protection *
* Normal ESD handling precautions should be observed.
2
C BUS
Fig. 1 Pin connections – top view
APPLICATIONS
Cable Tuning Systems
VCRs
ORDERING INFORMATION
SP5502F KG MPAS (14-lead miniature plastic package) SP5502S KG MPAS (16-lead miniature plastic package)
Fig. 2 Block diagram of SP5502S. (Ports P0 and P4 not present on SP5502F)
SP5502
ELECTRICAL CHARACTERISTICS
T
= 210°C to 180°C, VCC = 14·5V to 15·5V. All pin references are to the SP5502S (MP16 package).
AMB
These Characteristics are guaranteed by either production test or design. They apply within the specified ambient temperature and supply voltage ranges unless otherwise stated. Reference frequency 4MHz unless otherwise stated.
Characteristic Pin
Supply current Prescaler input voltage Prescaler input voltage
Prescaler input impedance Prescaler input capacitance
12
13,14
13,14
Min. Max.
Typ.
48
12·5
30
50
2
60 300 300
Units
mA mVrms mVrms
pF
Conditions
VCC = 5V 80MHz to 1GHz 1·3GHz, see Fig. 5
SDA, SCL
Value
Input high voltage Input low voltage Input high current Input low current Leakage current
4,5 4,5 4,5 4,5 4,5
3 0
V
CC
1·5
10
210
10
V V
µA
Input voltage = V
µA
Input voltage = 0V
µA
When VCC = 0V
CC
SDA
Output voltage
Charge pump current low Charge pump current high Charge pump output leakage current Charge pump drive output current Charge pump amplifier gain Recommended crystal series resistance Crystal oscillator drive level Crystal oscillator negative resistance
16
4 1
1
650
6170
1
500
0·4
65
V
Sink current = 3mA
µA
Byte 4, bit 2 = 0, pin 1 = 2V
µA
Byte 4, bit 2 = 1, pin 1 = 2V
nA
Byte 4, bit 4 = 1, pin 1 = 2V V pin 16 = 0·7V
6400
10
40
2
750
200
mV p-p
Parallel resonant crystal (note 2)
Output Ports
Sink current Leakage current
6,7,9-11 6,7,9-11
20
10
mA
µA
V
= 0·7V (see note 1)
OUT
V
= 13·2V
OUT
Input Port
P3 input current high P3 input current low
NOTES
1. Source impedance between all output ports and ground is approximately 5Ω . This should be taken into account when calculating output port saturation voltages.
2. The maximum resistance quoted refers to all conditions, including start-up.
8 8
1
20·5
mA
mA
V pin 8 = V V pin 8 = 0V
CC
FUNCTIONAL DESCRIPTION (Except where otherwise indicated, ‘SP5502’ refers to both variants)
The SP5502 is programmed from an I2C BUS. Data and Clock are fed in on the SDA and SCL lines respectively as defined by the I2C Bus format. The synthesiser can either accept new data (write mode) or send data (read mode). The Tables in Fig. 3 illustrate the format of the data. The device can be programmed to respond to several addresses, which enables the use of more than one synthesiser in an I2C Bus system. Table 3 shows how the address is selected by applying a voltage to P3. The address input is shown in Fig.
6. The LSB of the address Byte (R/W) sets the device into read mode if it is high and write mode if it is low. When the SP5502 receives a correct address Byte it pulls the SDA line low during the acknowledge period and during following acknowl­edge periods after further data Bytes are programmed. When the SP5502 is programmed into the read mode the controlling device accepting the data must pull down the SDA line during the following acknowledge period to read another status Byte.
2
WRITE MODE (FREQUENCY SYNTHESIS)
When the device is in the write mode Bytes 213 select the synthesised frequency while Bytes 415 select the output port states and charge pump information.
Once the correct address is received and acknowledged, the first Bit of the next Byte determines whether that Byte is interpreted as Byte 2 or 4, a logic 0 for frequency information and a logic 1 for charge pump and output port information. Additional data Bytes can be entered without the need to re­address the device until an I2C stop condition is recognised. This allows a smooth frequency sweep for fine tuning or AFC purposes.
If the transmission of data is stopped mid-byte (i.e., by another device on the bus) then the previously programmed byte is maintained.
Frequency data from Bytes 2 and 3 is stored in a 15-bit shift register and is used to control the division ratio of the 15-bit programmable divider which is preceded by a divide-by-8 prescaler and amplifier to give excellent sensitivity at the local oscillator input; see Fig 5. The input impedance is shown in Fig
7.
The programmed frequency can be calculated by multiply­ing the programmed division ratio by 8 times the comparison frequency F
COMP
.
When frequency data is entered, the phase comparator, via the charge pump and varactor drive amplifier, adjusts the local oscillator control voltage until the output of the program­mable divider is frequency and phase locked to the comparison frequency.
The reference frequency may be generated by an external source capacitively coupled into pin 2 or provided by an on­chip 4MHz crystal controlled oscillator.
Note that the comparison frequency is 7·8125kHz when a 4MHz reference is used.
Bit 2 of Byte 4 of the programming data (CP) controls the current in the charge pump circuit, a logic 1 for 6170µA and a logic 0 for 650µA, allowing compensation for the variable tuning slope of the tuner and also to enable fast channel changes over the full band. Bit 4 of Byte 4 (T0) disables the
SP5502
charge pump if set to a logic 1. Bit 8 of Byte 4 (OS) switches the charge pump drive amplifier’s output off when it is set to a logic 1. Bit 3 of Byte 4 (T1) selects a test mode where the phase comparator inputs are available on P2 and P7, a logic 1 connects F
Byte 5 programs the output ports P0-P2, P4 and P7 on the SP5502S (P1, P2 and P7 only on SP5502F), a logic 0 for a high impedance output, logic 1 for low impedance (on).
READ MODE
When the device is in the read mode the status data read from the device on the SDA line takes the form shown in Table 2. Bit 1 (POR) is the power supply to the device has dropped below a nominal 3V and the programmed information lost (e.g., when the device is initially turned on). The POR is set to 0 when the read sequence is terminated by a stop command. The outputs are all set to high impedance when the device is initially powered up. Bit 2 (FL) indicates whether the device is phase locked, a logic 1 is present if the device is locked and a logic 0 if the device is unlocked.
to P2 and F
COMP
DIV
to P7.
Address Programmable divider Programmable divider Charge pump and test bits I/O port control bits
Table 1 Write data format (MSB transmitted first)
Address Status byte
A : Acknowledge bit MA1, MA0 : Variable address bits (see Table 3) CP : Charge Pump current select T1 : Test mode selection T0 : Charge pump disable OS : Varactor drive Output disable Switch P7, P4*, P2, P1, P0* : Control output port states POR : Power On Reset indicator FL : Phase lock detect flag X : Don’t care N : Not valid
MSB
1
0
2
T1
0
13
12
2
5
4
2
2
T0
X
P4*
1
14
2
0
6
7
2
2
CP
1
X
P7
1FL0N0N0
1
POR
Table 2 Read data format
MA0
MA1
0 0 1 1
Voltage input to P3
0 1 0 1
0V to 0·1V
Open circuit
0·4VCC to 0·6VCC†
0·9VCC to V
Table 3 Address selection
LSB
0
11
2
3
2
1 X
N
CC
CC
MA1
10
2
2
2
1
P2
MA1
N
MA0
9
2
1
2
1
P1
MA0
N
0 2 2
OS
P0*
1
N
8
0
Byte 1
A
Byte 2
A
Byte 3
A
Byte 4
A
Byte 5
A
Byte 1
A
Byte 2
A
NOTES † Programmed by connecting a 15kΩ resistor between Address Select Port P3 and VCC.
Don’t care condition on SP5502F.
*
Fig. 3 Data formats
3
Loading...