MITEL MH88614 Datasheet

MH88614
Programmable CODEC SLIC
Advance Information
Features
Transformerless 2 -wire to 4- wire con versi on
Battery Feed
Ringing & M ess agin g Facil ity
Power Down with Wake Up output
Automat ic Ring Trip
Earth Grou nd B utton d etecti on
Switch Hook detectio n
Interface for a p rog ramm able CODE C
Ring g roun d over-current protec tion
Impedan ce reflec tion
Loop Leng th Indi cati on
Applications
Line Interfac e for
PABX
Intercoms
Key Telephone Syst ems
Control S ystem s
ISSUE 2 April 1995
Ordering Information
MH88614 30 Pin SIL Package
0°C to 70°C
Descript io n
The SLIC provides a complete interface between an industry standard programmable CODEC or DSP and a subscriber loop.
Functions provided include battery feed, zero crossing ring control, programmable current feed, power down with wake up signal, cadenced messaging facility, switch hook & dial pulse detection, loop length indication and the capability of reflecting a programmable CODEC’s impedance or supplying a standard 600 ohm impedance to the line. The device is fabricated as a thick film hybrid using various technologies for optimum circuit design high reliability.
VX VR
Loop
SHK EGB
LA
WU
LCA
RE
MSE
PD
2W-4W
Converter
Loop
Supervision
Constant
Current Control
Switch
Circuits
V
MSG
V
RNGVEEVDD
V
BAT
Figure 1 - Functional Block Diagram
Line Drivers
&
Battery Feed
A
GND
B
TIP
RING
GND
2-129
MH88614 Advance Information
IC IC
TIP
IC
RING
LOOP
BGND
WU
EGB
IC
VBAT
IC
PD
AGND
VDD
VEE
IC
VR
IC
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15
16 17
18
19 20
Figure 2 - Pin Connections
Pin Description
Pin # Name Descrip tio n
1ICInternal Connection 2ICInternal Connection
LCA
LA
VRING
VMSE
RE
MSE
SHK
IC
IC
IC
21 22 23 24 25 26 27 28 29
30
3 TIP Connects to the “Tip” lead of the telephone line. 4ICInternal Connection 5 RING Connects to the “Ring” lead of the telephone line 6LOOPLoop Length Indication. The output on this pin is proportional to the loop lengt h /
resistance, and is valid for off hook conditions only.
7BGNDB a ttery Gro und . This pin is the re turn pin for the bat tery feed to the line and also for the
message voltage supply and the Ring Voltage supply. This pin should normally be connected to AGND.
8WUWake Up(Output). When in the power down mode this pin goes high to indicate the phone
has gone off hook. When this occurs the power down signal should be removed.
9EGB
Earth Ground Button Detection (Output) This output goes low when the ring lead or tip
lead is grounded. 10 IC Internal Connection 11 VBAT Battery Feed Supply. This pin is the supply for the line feed. (Typically -48V). 12 IC Internal Connection 13 PD
Power Do wn (In pu t) Applying a logic 0 (Active low) will Power down the hybrid. This may
be used, but must be removed to allow a call to be made or to reduce power consumption. 14 AGND Analog Ground. This pin is the return pin for th e positi ve and negati ve supplies and is
normally connected to BGND. 15 VDD Positive S upp ly. (Typically +5V). 16 VEE N egati ve Su pp ly. (Typically -5V). 17 IC Internal Connection 18 VR Receive (Input). The audio inpu t signal is applied to this pin from the programmable
CODEC. This signal is internally a.c. coupled
2-130
Advance Information MH88614
Pin Description- (Continued)
Pin # Name Description
19 IC Internal Connection 20 VX Transmit (Output). The audio output signal appears on this pin and is internally a.c.
coupled. This signal is applied to the progra mmable CODE C . 21 IC Internal Connection 22 LCA L oo p Curr ent Adj ust (in pu t). The circuit has two constant current settings that are logic
selectable 23 IC Internal Connection 24 LA
25 IC Internal Connection 26 VRING Ring Voltage Supply. This pin is the supply for the Ringing signal to the telephone.
27 VMSE M essa ge Voltage Supply. This pin is the supply for the messag e signal to the telep hone.
28 RE Ring Enable (Input). The ringing signal is applied across Tip & Ring by applying a logic 1 to
29 MSE Message Signal Enable (Input). A cadenced signal can be applied to this pin which will
30 SHK
Functional Description
The MH88614 is an ONS SLIC for use with a programmable / intelligent CODEC or DSP. The SLIC performs all of the normal interface functions between the CODEC and the analog telephone set whilst having such additional features as Earth Ground Button Detection, message switching and Ringing switching with zero crossing.
Loop Alarm (Output) When the loop impedance exceeds the maximum limits that the SLIC
can support for a specified voltage & current this output will go low. This indicates that the
SLIC will no longer support the lin e. Note: Th is pin will also pulse low if Loop Disconnect
Dialling is perform ed, and goes low when the phone is on hoo k.
(Typically 90V
(Typically -100V)
this pin while the phone is “On Hook”. Ringing will be automatically stoppe d when the
phone goes “Off Hook” regardless of the state of the RE pin.
switch the V
prevent bell tinkle on the telephone. This is automatically switched off when the phone goes
off hook.
Switch Hook (Output). The outp ut of this pin goes low when the phone goes “O ff Hook”
and can be used externally to switch MSE off.
on -48V battery).
RMS
voltage onto Tip & Ring. The output voltage is internally conditioned to
MSG
Loop Supervision
The Loop Supervision circuit monitors the state of the phone line and provides three different output stages.
When the phone goes “Off Hook” the SHK low to indicate this state. This pin reverts to a high state when the phone goes back “On Hook” (see figure 3).
pin goes
The MH88614 is available as a 30 pin SIL package to increase board densities.
2 Wire to 4 Wire C onversi on
The hybrid performs 2 wire to 4 wire conversion by taking the 4 wire signal from the programmable CODEC at VR and converting it to a 2 wire differential signal at Tip & Ring. The 2 wire signal applied across Tip & Ring by the phone is converted to 4 wire signal at Vx which is the output from the SLIC to the programmable CODEC. Both the VR input & Vx output are internally a.c. coupled.
When the phone is off hook the circuitry can also detect two other features of the line status namely Earth Ground Button & Loop Alarm.
A logic low signal on the Earth Ground Button output indicates t hat an earth ground path has been applied to the Tip or Ring lead of the telephone. This function can be used for recall operations on phone sets with Earth Ground Buttons.
The Loop Alarm signal low to indicate that the R has been exceeded and that the circuit will no longer support the line.
Loop
2-131
Loading...
+ 7 hidden pages