QUICK SETUP GUIDE
fms
solo
®
Setup Diagram
[light backgrounds]
[
dark backgrounds]
[Black&White Only]
[
Red Surface]
[One-Color 185]
fms solo
®
Fluid Management System with Shaver Interface
(Disposable T
ubing Setup)
fms solo
®
Parts List
Sterile procedures should be followed wherever appropriate.
(Reference Product Manuals and Instructions For Use for complete instructions)
P
R
E
S
S
U
R
E
C
Y
C
L
E
®
Fill
Chamber
RUN/STOP
Pressure Cycle
Remote
Control
PRESSURE
ALARM
I
R
R
I
G
A
T
I
O
N
Advanced Irrigation
Pump
®
pressure
Run
Stop
Transparent Safety Cover 1
Tension Rocker Arm 2
Irrigation Roller Pump 3
Irrigation Auto-Locking Port. 4
Tube Holder. 5
Fill Chamber Button 6
Fill Chamber Holder 7
8
Pressure Display
9 Power Button
10
Alarm
1
1 Pressure Transducer Port
12 Pump Run/Stop Button
13 Pressure Adjustment Buttons
1
4 Pressure Cycle Button
Ports and Connectors on the Back
Shaver Interface Cable
Shaver Interface Power Cable
fms solo®Power Cable
Foot Pedal
B
asic Features on the Front
REF :4580
S
ERIALNUMBER :
SHAVER INTERFACE
FOOT PEDAL
INPUT POWER:
0197
IP54
TYPE B
CLASS I
REPLACE FUSES AS MARKED
120/230V~50-60Hz
500VA
D
ONOT REMOVE CONNECTOR WITHOUT
H
AVING TURNED OFF THE DEVICE.
CAUTION :
Advanced Irrigation Pump
®
Irrigation Tube
Intermediary Irrigation Tube without One-way Valve
Clamp
Clamp
C
lamp
Clamp
Auto-Locking Device
Pressure Chamber
1
2
8
9
3
4
5
1
2
3
4
5
13
14
7
10
12
11
6
I
rrigation tube
R
ed pedal is a timed cycle to
control bleeding
2 Portals in the knee
1-800-382-4682 www.depuymitek.com
©DePuy Mitek, Inc. 2008. All rights reserved. Printed in the USA.
P/N 901012. Rev. A 03/08
1
On/Off Switch
2 Fuses
3 Power Socket
4
S
haver Interface Port
5 Foot Pedal Port

S
H
A
V
E
R
I
N
T
E
R
F
A
CE
P
R
ESS
U
R
E
C
Y
C
L
E
A
. Connecting the Irrigation Tube
Quick Setup Guide (for Disposable Tubing)
1
2
3
a
g
b
c
d
e
f
F
i
l
l
C
h
a
m
b
e
r
G
A
d
v
an
c
e
d
I
r
r
i
g
at
i
o
n
P
u
m
p
®
I
R
R
I
G
A
T
I
O
N
F
i
l
l
C
h
a
m
b
e
r
A
d
v
a
n
c
e
d
I
r
r
i
g
a
t
i
o
n
P
u
m
p
®
I
R
R
I
G
A
T
I
O
N
F
i
l
l
Ch
a
m
b
e
r
A
d
v
a
n
c
e
d
I
rr
i
g
a
t
i
o
n
P
u
m
p
®
I
R
R
I
G
A
T
I
O
N
G
R
O
U
P
LEGAL MANUFACTURER:
DISTRIBUTED BY:
FUTURE MEDICAL SYSTEMS SA
265, Route de la Baronne
06640 SAINT JEANNET
FRANCE
www.fmsgroup.com
The Manufacturer andLicensed Seller of thi sdevicedonot accept any liability for direct or consequential
d
amage orinjury caused by its improper use,or usage of disposables other than FMS products.
Any alteration to this device, repair from unlicensed service center, or use ofnon FMS disposables will void
CEmarking, warranty, and product liability coverage.
This device iscoveredunder the following patents: US PATENT 4902 277 ,5000 733 , 5 131823
EUROPEAN PATENTS 0 306445, 0 448 909 - JAPANESE PATENT 2 107 259, 2 892 852 - Other patents
pending
FUTURE MEDICAL SYSTEMS SA
38 Chemin du Grand-Puits
1217 GENEVA
SWITZERLAND
F
UTURE MEDICAL SYSTEMS,Inc.
504 McCormick Drive
GLEN BURNIE, MD 21061
U
SA
®
REGISTERED TRADEMARK ofFUTURE MEDICAL SYSTEM SA
REF : 4580
S
ERIAL NUMBER :
SHAVER INTERFACE
FOOT PEDAL
IMPORTANT WARNING
ELECTRIC SHOCK HAZARD. DO NOT REMOVE COVER
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
DECKELNICHT ENTFERNEN-ELEKTROSCHOCKGEFAHR!
SERVICENUR VON EINGEWIESENEM FACHPERSONAL DURCHFÜHREN LASSEN
PRISE ELECTRIQUE-NE PAS ENLEVER LE COURVERCLE.
NEMETTRE EN SERVICEQUE PAR DU PERSONNELQUALIFIE.
INPUT POWER:
0197
IP54
TYPE B
CLASS I
REPLACE FUSES AS MARKED
120/230V~50-60Hz
500VA
CAUTION :
VORSICHT :
ATTENTION :
DO NOT REMOVE CONNECTOR WITHOUT
H
AVINGTURNED OFF THEDEVICE.
CAUTION :
Advanced Irrigation Pump
®
a
b
a: Connect the pressure transducer tube into the fill
chamber port. T
ur
n
clockwise until snug.
b
: Turn pump on by pressing Iswitch on back.
c
: Close lid and press POWER STAND-BY button.
d: Remove caps off irrigation spikes.
5
a: Insert spikes into irrigation bags.
b:
Open two (2) clamps on irrigation tubes.
c
: Press RUN STOP button. Prime pump to fifty (50).
d
: Press FILL CHAMBER button to pump fluid into
the chamber. Repeat until fluid rises to indicator
window (1/3 full).
e: Twist cap off irrigation tube.
Fill
Chamber
R
UN/STOP
P
ressure Cycle
Remote
Control
PRESSURE
ALARM
Advanced Irrigation Pump
®
pressure
Run
Stop
Fill
Chamber
R
UN/STOP
P
ressure Cycle
R
emote
Control
PRESSURE
A
LARM
A
dvanced Irrigation Pump
®
p
ressur
e
Run
Stop
a
: Lift lids and roller arm, then slide the green part of
the tube into the auto-locking feature on the pump.
b
: Place and center the tube around the roller. Pull
on the tube and close the tension rocker arm
against the tube.
c: Position the pressure chamber in the holder.
d: Twist cap off of the pressure transducer tube.
a: Remove irrigation tube from the package
and close three (3) white clamps on the
irrigation tube.
1
a: Remove the intermediary irrigation tube
without one-way valve fr
om the package
and close the white clamp.
b: Twist blue cap off the intermediary
irrigation tube.
a
: Insert power cable into socket.
b
: Attach the foot pedal connector
to the port.
c
: Attach shaver interface connector
to the port.
d: Insert power cable into interface cable.
e: Connect interface cable to shaver box.
f: Connect shaver to interface cable.
g: Insert power cables into wall socket.
Fill
Chamber
RUN/STOP
Pressure Cycle
Remote
Control
PRESSURE
ALARM
Advanced Irrigatio
nPump
®
pressure
Run
Stop
®
2
a:
Connect the irrigation tube to the intermediary irrigation
tube without one-way valve by screwing the two blue
connector ends together until snug.
b:
Open both clamps until fluid exits the tube. Close the clamp
nearest the end of the tube after fluid is released and place
in the sterile field.
b
fms solo
®
B. Connecting the Intermediary Irrigation Tube (without One-way Valve)
I
NF
L
OW
Fill
RUN/STOP
P
ressure Cycle
Remote
Control
P
RESSURE
A
LARM
A
dvanced Irrigation Pump
®
pressure
Run
Stop
C
hamber
b
a
3
a:
Connect the tube marked
INFLOW
to the arthr
oscopic
scope sheath.