SAFETY DATA SHEET
A00810 MST DUST MOP TREATMENT 20net18
Version 1.0
Print Date 06/01/2015
Material name
:
A00810 MST DUST MOP TREATMENT 20net18
Material number
:
000000000001003402
Company
:
Zep Inc.
Address
:
1310 Seaboard Industrial Blvd., NW Atlanta, GA 30318 Telephone
:
404-352-1680
Emergency telephone numbers
For SDS Information
:
Compliance Services 1-877-428-9937
For a Medical Emergency
:
877-541-2016 Toll Free - All Calls Recorded
For a Transportation Emergency
:
CHEMTREC: 800-424-9300 - All Calls Recorded. In the District of Columbia 202-483-7616
Appearance
Aerosol containing a liquefied gas
Colour
white
Odour
characteristic
Flammable aerosols
:
Category 2
Gases under pressure
:
Liquefied gas
Skin irritation
:
Category 2
Hazard pictograms
:
Signal word
:
Warning
Hazard statements
:
H223 Flammable aerosol. H280 Contains gas under pressure; may explode if heated. H315 Causes skin irritation.
Precautionary statements
:
Prevention: P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P211 Do not spray on an open flame or other ignition source. P251 Pressurized container: Do not pierce or burn, even after use. P264 Wash skin thoroughly after handling.
SECTION 1. PRODUCT AND COMPANY IDENTIFICATION
Manufacturer or supplier's details
SECTION 2. HAZARDS IDENTIFICATION
Emergency Overview
GHS Classification
GHS Label element
1 / 11
SAFETY DATA SHEET
A00810 MST DUST MOP TREATMENT 20net18
Version 1.0
Print Date 06/01/2015
P280 Wear protective gloves.
Response:
P302 + P352 IF ON SKIN: Wash with plenty of soap and water. P332 + P313 If skin irritation occurs: Get medical advice/ attention. P362 Take off contaminated clothing and wash before reuse. Storage: P410 + P412 Protect from sunlight. Do not expose to temperatures exceeding 50 °C/ 122 °F.
IARC
No component of this product present at levels greater than or equal to 0.1% is identified as probable, possible or confirmed human carcinogen by IARC.
ACGIH
No component of this product present at levels greater than or equal to 0.1% is identified as a carcinogen or potential carcinogen by ACGIH.
OSHA
No component of this product present at levels greater than or equal to 0.1% is identified as a carcinogen or potential carcinogen by OSHA.
NTP
No component of this product present at levels greater than or equal to 0.1% is identified as a known or anticipated carcinogen by NTP.
Chemical Name
CAS-No.
Concentration [%]
Distillates (petroleum), hydrotreated heavy naphthenic
64742-52-5
>= 10 - < 20
Distillates (petroleum), hydrotreated light (Vapour and gas)
64742-47-8
>= 5 - < 10 butane
106-97-8
>= 5 - < 10
Stoddard solvent
8052-41-3
>= 5 - < 10
propane
74-98-6
>= 1 - < 5
General advice
:
Show this safety data sheet to the doctor in attendance. Do not leave the victim unattended.
If inhaled
:
If unconscious place in recovery position and seek medical advice. If symptoms persist, call a physician.
In case of skin contact
:
If skin irritation persists, call a physician. Wash off immediately with plenty of water for at least 15 minutes. If on clothes, remove clothes.
Potential Health Effects
Carcinogenicity:
SECTION 3. COMPOSITION/INFORMATION ON INGREDIENTS
Hazardous components
SECTION 4. FIRST AID MEASURES
2 / 11
SAFETY DATA SHEET
A00810 MST DUST MOP TREATMENT 20net18
Version 1.0
Print Date 06/01/2015
In case of eye contact
:
Remove contact lenses. Flush eyes with water at least 15 minutes. Get medical attention if eye irritation develops or persists.
If swallowed
:
Keep respiratory tract clear. DO NOT induce vomiting unless directed to do so by a physician or poison control center.
Suitable extinguishing media
:
Alcohol-resistant foam Carbon dioxide (CO2) Dry chemical Water spray jet
Unsuitable extinguishing media
:
High volume water jet
Specific hazards during firefighting
:
Do not allow run-off from fire fighting to enter drains or water courses.
Hazardous combustion products
:
Carbon dioxide (CO2) Carbon monoxide Smoke
Specific extinguishing methods
:
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
Further information
:
Collect contaminated fire extinguishing water separately. This must not be discharged into drains. Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations. For safety reasons in case of fire, cans should be stored separately in closed containments. Use a water spray to cool fully closed containers.
Special protective equipment for firefighters
:
Wear self-contained breathing apparatus for firefighting if necessary.
Personal precautions, protective equipment and emergency procedures
:
Use personal protective equipment. Ensure adequate ventilation. Remove all sources of ignition. Evacuate personnel to safe areas. Beware of vapours accumulating to form explosive concentrations. Vapours can accumulate in low areas.
Environmental precautions
:
Prevent product from entering drains. Prevent further leakage or spillage if safe to do so. If the product contaminates rivers and lakes or drains inform respective authorities. Methods and materials for
:
Soak up with inert absorbent material (e.g. sand, silica gel,
SECTION 5. FIREFIGHTING MEASURES
SECTION 6. ACCIDENTAL RELEASE MEASURES
3 / 11
SAFETY DATA SHEET
A00810 MST DUST MOP TREATMENT 20net18
Version 1.0
Print Date 06/01/2015
containment and cleaning up
acid binder, universal binder, sawdust). Sweep up or vacuum up spillage and collect in suitable container for disposal.
Advice on safe handling
:
Avoid contact with skin and eyes. For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area. Take precautionary measures against static discharges. Provide sufficient air exchange and/or exhaust in work rooms. Open drum carefully as content may be under pressure. Always replace cap after use. Dispose of rinse water in accordance with local and national regulations. Do not breathe vapours or spray mist.
Conditions for safe storage
:
BEWARE: Aerosol is pressurized. Keep away from direct sun exposure and temperatures over 50 °C. Do not open by force or throw into fire even after use. Do not spray on flames or red-hot objects. No smoking. Containers which are opened must be carefully resealed and kept upright to prevent leakage. Observe label precautions. Electrical installations / working materials must comply with the technological safety standards. Keep in a dry, cool and well-ventilated place.
Materials to avoid
:
Strong oxidizing agents
Components
CAS-No.
Value type (Form of exposure)
Control parameters / Permissible concentration
Basis Distillates (petroleum),
hydrotreated heavy naphthenic
64742-52-5
TWA (Mist)
5 mg/m3
OSHA Z-1
TWA (Inhalable fraction)
5 mg/m3
ACGIH
Distillates (petroleum), hydrotreated light (Vapour and gas)
64742-47-8
TWA
500 ppm 2,000 mg/m3
OSHA Z-1 TWA
400 ppm 1,600 mg/m3
OSHA P0
butane
106-97-8
TWA
800 ppm 1,900 mg/m3
NIOSH REL TWA
800 ppm
OSHA P0
SECTION 7. HANDLING AND STORAGE
SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Components with workplace control parameters