A00810 MST DUST MOP TREATMENT 20net18
A00810 MST DUST MOP TREATMENT 20net18
1310 Seaboard Industrial Blvd., NW
Atlanta, GA 30318
Telephone
Emergency telephone numbers
Compliance Services 1-877-428-9937
877-541-2016 Toll Free - All Calls Recorded
For a Transportation
Emergency
CHEMTREC: 800-424-9300 - All Calls Recorded.
In the District of Columbia 202-483-7616
Aerosol containing a liquefied gas
H223 Flammable aerosol.
H280 Contains gas under pressure; may explode if heated.
H315 Causes skin irritation.
Prevention:
P210 Keep away from heat, hot surfaces, sparks, open flames
and other ignition sources. No smoking.
P211 Do not spray on an open flame or other ignition source.
P251 Pressurized container: Do not pierce or burn, even after
use.
P264 Wash skin thoroughly after handling.
SECTION 1. PRODUCT AND COMPANY IDENTIFICATION
Manufacturer or supplier's details
SECTION 2. HAZARDS IDENTIFICATION
Emergency Overview
GHS Classification
GHS Label element
1 / 11
A00810 MST DUST MOP TREATMENT 20net18
P280 Wear protective gloves.
Response:
P302 + P352 IF ON SKIN: Wash with plenty of soap and water.
P332 + P313 If skin irritation occurs: Get medical advice/
attention.
P362 Take off contaminated clothing and wash before reuse.
Storage:
P410 + P412 Protect from sunlight. Do not expose to
temperatures exceeding 50 °C/ 122 °F.
No component of this product present at levels greater than or
equal to 0.1% is identified as probable, possible or confirmed
human carcinogen by IARC.
No component of this product present at levels greater than or
equal to 0.1% is identified as a carcinogen or potential
carcinogen by ACGIH.
No component of this product present at levels greater than or
equal to 0.1% is identified as a carcinogen or potential
carcinogen by OSHA.
No component of this product present at levels greater than or
equal to 0.1% is identified as a known or anticipated carcinogen
by NTP.
Distillates (petroleum), hydrotreated heavy
naphthenic
Distillates (petroleum), hydrotreated light (Vapour
and gas)
Show this safety data sheet to the doctor in attendance.
Do not leave the victim unattended.
If unconscious place in recovery position and seek medical
advice.
If symptoms persist, call a physician.
If skin irritation persists, call a physician.
Wash off immediately with plenty of water for at least 15
minutes.
If on clothes, remove clothes.
Potential Health Effects
Carcinogenicity:
SECTION 3. COMPOSITION/INFORMATION ON INGREDIENTS
Hazardous components
SECTION 4. FIRST AID MEASURES
2 / 11
A00810 MST DUST MOP TREATMENT 20net18
Remove contact lenses.
Flush eyes with water at least 15 minutes. Get medical
attention if eye irritation develops or persists.
Keep respiratory tract clear.
DO NOT induce vomiting unless directed to do so by a
physician or poison control center.
Suitable extinguishing media
Alcohol-resistant foam
Carbon dioxide (CO2)
Dry chemical
Water spray jet
Unsuitable extinguishing
media
Specific hazards during
firefighting
Do not allow run-off from fire fighting to enter drains or water
courses.
Hazardous combustion
products
Carbon dioxide (CO2)
Carbon monoxide
Smoke
Specific extinguishing
methods
Use extinguishing measures that are appropriate to local
circumstances and the surrounding environment.
Collect contaminated fire extinguishing water separately. This
must not be discharged into drains.
Fire residues and contaminated fire extinguishing water must
be disposed of in accordance with local regulations.
For safety reasons in case of fire, cans should be stored
separately in closed containments.
Use a water spray to cool fully closed containers.
Special protective equipment
for firefighters
Wear self-contained breathing apparatus for firefighting if
necessary.
Personal precautions,
protective equipment and
emergency procedures
Use personal protective equipment.
Ensure adequate ventilation.
Remove all sources of ignition.
Evacuate personnel to safe areas.
Beware of vapours accumulating to form explosive
concentrations. Vapours can accumulate in low areas.
Environmental precautions
Prevent product from entering drains.
Prevent further leakage or spillage if safe to do so.
If the product contaminates rivers and lakes or drains inform
respective authorities.
Methods and materials for
Soak up with inert absorbent material (e.g. sand, silica gel,
SECTION 5. FIREFIGHTING MEASURES
SECTION 6. ACCIDENTAL RELEASE MEASURES
3 / 11
A00810 MST DUST MOP TREATMENT 20net18
containment and cleaning up
acid binder, universal binder, sawdust).
Sweep up or vacuum up spillage and collect in suitable
container for disposal.
Avoid contact with skin and eyes.
For personal protection see section 8.
Smoking, eating and drinking should be prohibited in the
application area.
Take precautionary measures against static discharges.
Provide sufficient air exchange and/or exhaust in work rooms.
Open drum carefully as content may be under pressure.
Always replace cap after use.
Dispose of rinse water in accordance with local and national
regulations.
Do not breathe vapours or spray mist.
Conditions for safe storage
BEWARE: Aerosol is pressurized. Keep away from direct sun
exposure and temperatures over 50 °C. Do not open by force
or throw into fire even after use. Do not spray on flames or
red-hot objects.
No smoking.
Containers which are opened must be carefully resealed and
kept upright to prevent leakage.
Observe label precautions.
Electrical installations / working materials must comply with
the technological safety standards.
Keep in a dry, cool and well-ventilated place.
Value type
(Form of
exposure)
Control
parameters /
Permissible
concentration
Basis
Distillates (petroleum),
hydrotreated heavy naphthenic
Distillates (petroleum),
hydrotreated light (Vapour and
gas)
SECTION 7. HANDLING AND STORAGE
SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Components with workplace control parameters
4 / 11