TLD Dosimeter for RE-2000 Readers
Passive Dosimetry
TLD Dosimeter
for RE-2000 Readers
RADOS Thermoluminescence Dosimetry system
covers a wide range of applications:
RADOS TLD System includes all the components
needed for easy and accurate Personal
Dosimetry.
Easy adaption of high sensitive TL-materials and
low noise photon counting measurement method
makes the RADOS system extremely suitable for
environmental dosimetry.
FEATURES
personnel dosimetry•
extremity dosimetry•
environmental monitoring•
medical dosimetry applications•
exible badge construction•
Ingenious dosimeter card construction and high
measurement range bring the advantages of an
automatic reader to clinical dosimetry
applications.
The RADOS badge design allows the exchange
of lter materials, lter thickness and TLmaterials. This is both to satisfy the needs of
different applications and also to offer the
possibility of applying new TL-materials easy.
The standard TLD dosimeter card consists of
a coded slide placed in a slide holder, with or
without lters, and carried inside the dosimeter
cover.
The slide has four positions for the detectors
(pellets, chips or rods). The detectors are not
attached to the slide positions and any required
number of positions up to four can be used.This
makes it possible to handle the elements
separately (e.g. extremity or clinical dosimetry).
health physics
A Mirion Technologies Division
Featuring:
TLD Dosimeter for RE-2000 Readers
Passive Dosimetry
The slide holders of the standard dosimeters are supplied in 6 different colours. The lter positions (front and back
of the holder) may be equipped with up to 1 mm thick Al lters, or it is possible for the customer to insert lters
of their own choice. The fourth detector position is for measuring shallow (skin) dose produced by betas and low
energy photons.
In the personal dosimetry the dosimeters are kept in a plastic cover. The number of the slide is visible when the slide
is in the holder and the dosimeter card in the plastic cover. On the backside of the cover there is space for a name
tag.The name tag and a barcoded number of the slide are visible trough the back part.
card with lter
Hp(10) energy response with MCP-N detectors
Hp(10) energy response with MTS-N detectors
card without lter
www.mirion.com
20996042_TLDdosimeter_EN_A
MGP Instruments Inc
5000 Highlands Parkway
Suite 150
Smyrna Georgia 30082
USA
T +1.770.432.2744
F +1.770.432.9179
MGP Instruments SA
BP 1
F-13113 Lamanon
France
T +33 (0) 4 90 59 59 59
F +33 (0) 4 90 59 55 18
RADOS Technology Oy
P.O. Box 506
FIN-20101 Turku
Finland
T +358 2 4684 600
F +358 2 4684 601
RADOS Technology GmbH
Ruhrstrasse 49
D-22761 Hamburg
Germany
T +49 40 85193 0
F +49 40 85193 256