Mirion Technologies SGLM 202K User Manual

Featuring:
radiation monitoring systems
A Mirion Technologies Division
SGLM 202K
Special Monitors
SGLM 202K
The SGLM 202K from the RAMSYS product line has
been developed for steam generator leak rate
monitoring in WWER nuclear power plants.
The 16N volume activity (in counts per second/Cps)
measured by a NaI scintillation detector inside a lead
shielding facing the live steam line is converted to
Bq/m3 (or µci/cc) through a coef cient calculated
from Monte Carlo analysis on the basis of relevant
data provided by the user. An algorithm which is
based upon thermal hydraulic transport phenomena
modeling uses the measured 16N activity, the reactor
power, the steam  ow rate and the transport time
(in the primary and in the secondary loop) to assess
the steam generator leak rate.
APPLICATIONS
• Barrier leak control
Secondary circuit monitoring
RELATED MONITORS
• SGLM 201K: version for PWR nuclear power plants
FEATURES
16
N monitoring when reactor power exceeds 25%
Gross gamma energy monitoring when reactor
power < 25%
Spectrum stabilization against temperature and aging
drifts
16 selectable windows over the range covered
1024 channels analysis
Available with or without display and local signaling
Seismically quali ed
More than 500 SGLM channels in operation worldwide
De ned for mild environment conditions
Since norms, speci cations and designs are subject to occasional change, please ask for con rmation of the information given in this publication.
Mirion Technologies (MGPI) SA
Route d’Eyguières FR-13113 Lamanon France
T +33 (0) 4 90 59 59 59 F +33 (0) 4 90 59 55 18
Mirion Technologies (MGPI) Inc
5000 Highlands Parkway Suite 150 Smyrna, GA 30082 USA T +1 770 432 2744 F +1 770 432 9179
Mirion Technologies (MGPI H&B) GmbH
Landsberger Strasse 328a DE-80687 Munich Germany
T +49 (0) 89515 13-0 F +49 (0) 89515 13 169
Mirion Commercial (Beijing) Co., Ltd.
Shanghai Jiangchang Commercial Branch
Room 801, 78 Jiangchang SanLu Zhabei District, Shanghai 200436 PR of China T +86 21 6180 6920 F +86 21 6180 6924
SGLM 202K
Special Monitors
PHYSICAL CHARACTERISTICS
Radiation detected: gamma
Detector: 3”x2” NaI(TI) scintillator + PMT
Energy range:
○ 16
N window: 4.5 MeV to 7 MeV
Gamma window: 0.2 MeV to 2.2 MeV
Measurement range: Leak rate: 1 to 5 000 l/h
(6 to 31 700 GPD)
Gamma: 0.5 to 100 000 cps
Spectrum analysis: 1024 channels
Lead shield: 2 π / 5 cm (2 π / 2 in)
ENVIRONMENTAL CHARACTERISTICS
Long term temperature:
+10°C to +40°C (+50°F to +104°F)
Periodic temperature:
-5°C to +55°C (+23°F to +131°F)
MTBF: > 20 000 hours
TID: 100 Gy (10
+4
rad)
Protection index: IP65 and IK07
MECHANICAL CHARACTERISTICS
Dimensions: Processing unit: 390 mm x 196 mm x 187 mm
(15.3 in x 7.7 in x 7.3 in)
Detector: Ø 402 mm x 429 mm (Ø 15.8 in x 16.9 in)
Weight:Processing unit: 8 kg (17.6 lb)Detector: 226 kg (498 lb)
Color: gray RAL 7030 (decontaminable paint)
ELECTRICAL CHARACTERISTICS
Power supply: 230 Vac – 50 Hz or 120 Vac – 60 Hz
Data link outputs: 1 RS232 and 2 isolated RS485
Alarm relays: 3 SPDT relays
I/O: 2 isolated analog outputs and 1 isolated analog
input (0/4-20 mA)
SIGNALING (Applicable to LPDU only)
Alphanumeric display: measurement, status…
Sound alarm: buzzer 90 dBA at 1 meter
Visual alarm: 3 lights (red, yellow, green)
REFERENCE STANDARDS
Seismic: IEEE344 and IEC60980
EMC: 2006/95/CE, 2004/108/CE, EPRI 102323, MIL
STD 461 E, IEC61000-6-2 and IEC61000-6-4
VERSIONS
230 Vac or 120 Vac
LPDU or LPU
With or without RS485 junction box
Detector cable length: from 20 m (65.6 ft)
to 100 m (328 ft)
Junction box cable length: 2 m (6.56 ft), 5 m (16.4 ft)
or 10 m (32.8 ft)
ACCESSORIES
Calibration tools
Software
USB converters
Seismic quali ed wall mounting bracket for LP(D)U
Detection sub-assembly support
www.mirion.com
144430EN-F
Loading...