Mirion Technologies RAD-60 User Manual

RAD-60 Personal Alarm Dosimeter
Active Dosimetry
RAD-60
Personal Alarm Dosimeter
RADOS RAD-60 Personal Alarm Dosimeter is a precise radiation measuring instrument for reliable detection and registration of radiation in order to ensure the personal safety of the user. It is suitable for a broad range of everyday radiation monitoring purposes in stand alone conditions.
Applications in:
FEATURES
enhanced EMI immunity • rugged clip fi xing • improved wear-out and decontamination • properties increased sound pressure
individual Personal Alarming Dosimeter• digital display for integrated dose or alternatively • dose rate user selectable alarm levels for both dose and dose • rate
Civil Defence
Rescue Operations
Customs Operations
Military Forces
Industrial Radiography
Nuclear Medicine
health physics
A Mirion Technologies Division
Featuring:
TECHNICAL SPECIFICATIONS:
Physical characteristics Radiation detected:
RAD-60 Personal Alarm Dosimeter
Active Dosimetry
gamma and X-rays Detectors:• energy compensated Si-Diode Measurement range:
- dose: 1 µSv - 9.99 Sv or 0.1 mrem - 999 rem
- dose rate: 5 µSv/h - 3 Sv/h or 0,5 mrem/h - 300 rem/h Calibration:• better than ±5% (Cs-137, 662 keV at 2 mSv/h), Hp(10) Energy response:• Hp(10), 60 keV - 3 MeV, better than ±25%, up to 6 MeV, better than ±35% Dose rate linearity:• better than ±15%, up to 3 Sv/h (300rem/h) Audible alarms:
- eight separate alarms, sound level typically better than 85 dBA at 30 cm
- integrated dose
- dose rate
- dose over ow
- dose rate over  ow at 3 Sv/h or 300 rem/h
- low battery 1and 2
- defect Alarm thresholds*:• seven preset values each for integrated dose and dose rate, manually selectable by push-button Push-button functions*:
- front panel push-button has the following selectable functions:
- toggle between dose and dose rate display
- switch ON/OFF
- chirp ON/OFF
- reset integrated dose
- change alarm thresholds
- activate battery test
Mechanical characteristics Dimensions: 78 x 67 x 22 mm
Envirionmental Characterstics Temperature range:
Electrical characteristics Power supply:
MGP Instruments Inc 5000 Highlands Parkway Suite 150 Smyrna Georgia 30082 USA T +1.770.432.2744 F +1.770.432.9179
MGP Instruments SA
BP 1 F-13113 Lamanon France T +33 (0) 4 90 59 59 59 F +33 (0) 4 90 59 55 18
*Note: the active alarm tresholds and con guration of push button functions can be changed by using ADR-1 Reader Head in combination with RADOS PC Software.
Weight: 80 g including battery
-20 oC to +50 oC operational, humidity up to 90% RH, non condensed
one triple A alkaline cell, life typically 1800 h in background  eld (dose mode) Reader communication:• by infrared through bottom part; by using ADR-1 Reader Head in • combination with RADOS PC software
www.mirion.com
20996027_RAD60_EN_A
RADOS Technology Oy
P.O. Box 506 FIN-20101 Turku Finland T +358 2 4684 600 F +358 2 4684 601
RADOS Technology GmbH
Ruhrstrasse 49 D-22761 Hamburg Germany T +49 40 85193 0 F +49 40 85193 256