Mirion Technologies R600 User Manual

Control Cabinets: Standard Installation Hardware and Control Equipment for VENTUS High Temperature Camera or Probes
R600 VENTUS
The R600 Standard Control is designed to pro-
Features
• Air or water cooled systems
• Temperature monitoring
• Air purge pressure monitoring
• Local status display
QUADTEK
• Remote display with audible alarm
• Wall or Rail hook mounting
• IP55 sealed industrial metal enclosure with epoxy paint finish
• IP65 versions available
vide status monitoring for the Quadtek Ventus line of high temperature cameras and probes. These are available with remote visual status display, audible alarms for coolant supply failure, low flow rate and over temperature of the CCD electronics and lens assemblies.
Imaging & Sensing Technology Corporation
Specifications and Performance
132
18 20 47
115
The Quadtek R600 Control System comprises a complete schedule of material for installation of a Quadtek High Temperature Television System. The hardware package can be specified to work with the complete range of Quadtek Ventus high temperature television cameras.
The Quadtek Ventus series cameras are also supplied with a mating gimbal flange assembly, which allows for a simple four bolt fixing to a boiler or furnace, the gimbal comprises a mounting flange, locking plate, gimbal, shutter and sleeve. The sleeve mounts to the camera, setting the insertion distance and providing for quick removal of the unit for maintenance. The shutter acts as a retaining catch for the sleeve and covers the viewing port when a camera is not fitted. By loosening the bolts on the locking plate the gimbal can be adjusted to give ±10° of axial movement for fine adjustment of the direction of camera/probe view.
All cameras use a standard five meter composite cable for connection of power, video and temperature sensing to the local Quadtek R600 Camera Interface Unit. The cooling hoses are specific to the camera cooling system, although all systems use a common five meter hose assembly between the camera and Quadtek R600 Interface Unit for air cooling and purging. The input compressed air supply is via a one meter hose assembly to a filter regulator assembly comprising; 40 µm coalescing filter with shut off valve, pressure relieving regulator and manual drain. Termination of the plant compressed air supply is direct to the filter regulator via a 1/2" BSP fitting. For water cooled systems, two additional five meter hose assemblies and an additional one meter hose assembly are provided for water supply and drain from the camera to the local Quadtek R600 Interface Unit, and from there to the plant drain. All hose assemblies use Aeroquip SH925 hose with 1/2" BSP brass fittings.
ø300.0
ø256.0
ø225.0
4 HOLES ø27 THRO' EQUI-SPACED AS SHOWN
ø146.0
Optional coalescing filter assemblies and water filter/regulators are available to clean coolant supplies to the specified conditions.
The system control and monitoring is provided from two wall mounted enclosures which provide camera power, status sensing and alarm outputs and a desk top free-standing 14” color display monitor. The R600 Camera Interface is mounted locally to the camera, while the Quadtek R600 Control Box is located in the control room adjacent to the monitor, where the operators can view the monitor and see the status indication. Alternatively, both enclosures may be installed adjacent to one another at the camera location; in this case, the voltage-free relay contacts are used to annunciate faults in the control room.
The Quadtek R600 Camera Interface is selected with either an air flow or water flow sensor depending upon the camera main cooling system and operates from a low dc voltage supplied by the Quadtek R600 Camera Control Box. The camera status is monitored by a thermocouple, coolant flow switch and air purge pressure switch, which interfaces with a printed circuit board providing full condition monitoring. A built-in self test and calibration circuit are provided for simple system test and commissioning of the status and alarm outputs to the Control Box. The Camera Control Box can be supplied with a glanded cable entry or MIL specification connectors, the main power supply is regulated to a low DC supply to the local interface and a relay board provides status and alarm indication with a remote output. An industrial grade color display monitor provides high quality video from the camera / probe to the operator. A full range of video monitors, switching and recording CCTV components are available to meet specific needs. Please contact IST for further information.
QUADTEK R600 VENTUS
Typical Standard System Configuration
CAMERA/PROBE
1
2
*Dotted line for water cooled cameras only.
*
GIMBAL MOUNTING
E
FLANG
6a 6
6a
7 4
5
11
8
CAMERA INTERFACE
7a
UP TO 250 METRES
AIR FILTER/ REGULATOR
3
WATER DRAIN
VIDEO
ALARM OUTPUT
10
COOLANT SUPPLY
WATER INPUT
AIR INPUT
9
MONITO
R
~
CAMERA
CONTROL BOX
~ 120V 50/60Hz (Std)
230V 50/60Hz (Optional
)
1 High Temperature Camera or Probe ------------------------------------------------------------------------------------------------------------------------------R600 Series
2 Gimbal Mounting Flange. ------------------------------------------------------------------------------------------------------------------------------------------ R600 Series
3 R600 Camera Interface.------------------------------------------------------------------------------------------------------------------ Air cooled system - R600CIA03A
-------------------------------------------------------------------------------------------------------------------------------------------- Water cooled system - R640CIA03A
4 R600 Single Air Filter/Regulator. ---------------------------------------------------------------------------------------------------------------------------------- GAS.00160
5 R600 Camera Cable (5 metres long). --------------------------------------------------------------------------------------------------------------------------- R600CAB03A
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
6 R600 cooling hose; Aeroquip SH925 with 1/2" BSP fittings (5 metres) -------------------------------------------------------------------------------- R600CHB03A
6a R600 cooling hose; Aeroquip SH925 with 1/2" BSP fittings (5 metres) --------------------------------------------------------------------------------R600CHA03A
7 R600 cooling hose Aeroquip SH925 with 1/2" BSP fittings (1 metre) ---------------------------------------------------------------------------------- R600CHB04A
7a R600 cooling hose Aeroquip SH925 with 1/2" BSP fittings (1 metre) ---------------------------------------------------------------------------------- R600CHB04A
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
8 R600 Control Box ------------------------------------------------------------------------------------------------------------------------------------R600CBA03A (connector)
--------------------------------------------------------------------------------------------------------------------------------------------------------------R600CBB03A (Glands)
----------------------------------------------------------------------------------------------------------------------------------------- R600CRA03A (19" rack mount version)
9 Colour monitor 14" screen; metal case, 110-260VAC, PAL/NTSC ---------------------------------------------------------------------------------------- MON.00460
10 Video coaxial cable RG59 ------------------------------------------------------------------------------------------------------------------------------------------- CAB.00420
11 Cross site cable composite video, power and alarms ----------------------------------------------------------------------------- R600CAB06A (for CBA and CRA)
-------------------------------------------------------------------------------------------------------------------------------------------------------------R600CAB07A (for CBB)
Please refer to IST technical datasheets for component specifications.
QUADTEK R600 VENTUS
Camera Interface R600CIA03A/R640CIA03A
Electrical Supply
Supply voltage ................................. 39V dc maximum from R600
control box
Compressed Air
Quality ............................................. Dry oil free instrument air
Supply pressure ............................... 4 to 10 bar g (58-145 psi)
Regulated pressure ......................... 2 bar minimum (30 psi)
3
Flow rate ..........................................10dm
s-1 (21 SCFM)
Temperature..................................... 20°C (68°F)
Cooling Water Supply (R640CIA03A only)
Quality ............................................. Clean/Sediment free
Supply pressure ............................... 4 bar (58 psi)
Flow rate ..........................................15 litres per minute
Temperature..................................... 35°C (95°F) (typically)
pH value ...........................................6 to 8
Camera Control Box: R600CBA03A / R600CBB03A / R600CRA03A
Electrical Supply
Supply voltage ................................. 100-120/200-240V ac 50/60Hz
Power ...............................................50VA (max)
Supply tolerance ..............................± 6% frequency
Camera Control Unit (Basic System) R600CBD03A
Electrical Supply
Supply voltage ................................. 85-264 VAC; 47-63Hz
Power ...............................................30w nominal
Output Signals
Video ................................................Composite video IV P-P (PAL/NTSC)
Over Temperature Alarm .................Voltage-free ND/NC rated 240 VAC SA
Environmental
Enclosure ......................................... IP55 or IP65
Ambient temperature ...................... 0° - 40°C
Relative humidity .............................0 - 80% non condensing
Output Signals
Video ................................................Composite video 1V p-p PAL/NTSC
Over temperature alarm .................. Volt free NO/NC rated 240V ac 5A
Coolant fail alarm ............................ Volt free NO/NC rated 240V ac 5A
Indication
Green indicator ................................ Power on
Red indicator ................................... Over temperature with audible alarm
Red indicator ................................... Coolant fail with audible alarm
Imaging and Sensing Technology Corporation
204 IST Center Horseheads, NY 14845 USA Tel: 607-562-4300 800-432-1478 Fax: 607-562-4392 E-mail: istrees@istcorp.com