Particulate, Gas & Iodine Monitors
PM 205S
Beta Particulate Monitor
product line. It has been developed to continuously
measure the volumetric activity of a radioactive
gaseous sample containing particulates. The sample
is drawn from discharge stacks, reactor building, ven-
tilation ducts or working areas via a pumping system.
It is then admitted into a detection unit where the
particulates are trapped on a  lter. It is typically used
for monitoring particulate volumetric activity under
normal operating and mild-environment conditions.
This monitor can operate as a stand alone device or
in conjunction with an iodine monitor (IM 201), and/or
noble gas monitors (NGM 203, NGM 204, NGM 214,
NGM 216) to form a complete monitoring system.
FEATURES
1E quali cation and embedded safety related software
Available under 10 CFR 50 App. B, IEC 61226 and
ASME NQA-1 programs for safety related application
APPLICATIONS
• Effl uent release monitoring
RELATED MONITORS
• IM 201S: iodine monitor
• NGM 203S: high range noble gas monitor
• NGM 204S: low range noble gas monitor
• NGM 214S: low range beta noble gas monitor
• NGM 216S: low range beta noble gas monitor
radiation monitoring systems
A Mirion Technologies Division
Featuring:
PM 205S
Particulate, Gas & Iodine Monitors
PHYSICAL CHARACTERISTICS
Radiation detected: beta
Detector: 2’’ thin plastic scintillator + PMT +
embedded LED
Filter type:  berglass 49 mm (1.9 in)
Lead shield: 7.5 cm/4 π (3 in/4 π)
Typical energy range: > 30 keV
Typical measurement range: 3.7 10
-12
(10
to 10-7 μCi/cc)
-2
to 3.7 10+3 Bq/m3
ENVIRONMENTAL CHARACTERISTICS
Long term temperature: +10°C to +40°C
(+50°F to +104°F)
Periodic temperature (processing unit):
-5°C to +55°C (+23°F to +131°F)
Periodic temperature (detector):
+0°C to +60°C (+32°F to +140°F)
MTBF (processing unit): > 50 000 hours
MTBF (detector): > 20 000 hours
TID: 100 Gy (10
Protection index: IP65 and IK07
+4
rad)
ELECTRICAL CHARACTERISTICS
Power supply: 230 Vac – 50 Hz or 120 Vac – 60 Hz
Data link outputs: 1 RS232 and 2 isolated RS485
Alarm relays: 3 SPDT relays
I/O: 2 isolated analog outputs and 1 isolated analog
input (0/4-20 mA)
SIGNALING (Applicable to LPDU only)
Alphanumeric display: measurement, status…
Sound alarm: buzzer 90 dBA at 1 meter
Visual alarm: 3 lights (red, yellow, green)
REFERENCE STANDARDS
Nuclear: IEC60761-1 and IEC60761-2, IEC61172,
IEC61578
Environmental: IEC60780, IEEE323
Seismic: IEC60980, IEEE344
EMC: 2006/95/CE and 2004/108/CE, EPRI 102323,
MIL STD 461 E, IEC61000-6-2 and IEC61000-6-4
VERSIONS
PNEUMATIC CHARACTERISTICS
Standard  ow rate: 28.3 l/min (1 scfm)
Pressure drop: 50 mbar (0.73 psi)
MECHANICAL CHARACTERISTICS
Dimensions: 889 mm x 1397 mm x 1651 mm
(35 in x 55 in x 65 in)
Weight: 700 kg (1543 lb)
Color: gray RAL 7030 (decontaminable paint)
Inlet tube connection: Ø 1 in
Outlet tube connection: Ø 1/2 in
Mirion Technologies (MGPI) SA
Route d’Eyguières FR-13113 Lamanon France
T +33 (0) 4 90 59 59 59 F +33 (0) 4 90 59 55 18
Mirion Technologies (MGPI) Inc
5000 Highlands Parkway Suite 150 Smyrna, GA 30082 USA T +1 770 432 2744 F +1 770 432 9179
230 Vac or 120 Vac
LPDU or LPU
With or without check source
With or without heater
PIS sampler
ACCESSORIES
Calibration tools
Software
Ethernet
USB converters
Mirion Technologies (MGPI H&B) GmbH
Landsberger Strasse 328a DE-80687 Munich Germany
T +49 (0) 89515 13-0 F +49 (0) 89515 13 169
www.mirion.com
151004EN-A
Mirion Commercial (Beijing) Co., Ltd. Shanghai Jiangchang Commercial Branch
Room 801, 78 Jiangchang SanLu Zhabei District, Shanghai 200436 PR of China T +86 21 6180 6920 F +86 21 6180 6924
Since norms, speci cations and designs are subject to occasional change, please ask for con rmation of the information given in this publication.