PING 207S
Combination Monitors
PING 207 S
Particulate Iodine and Noble Gas Monitor
The PING 207S monitor forms part of the RAMSYS
product line. It has been developed to continuously
measure the particulate, iodine and noble gas
volumetric activities in stacks, ventilation ducts or
working areas. It integrates all the functions and
performances of the PM 205, IM 201 and
NGM 216 monitors into a single monitor.
APPLICATIONS
• Effl uent release monitoring
○ Stacks, etc.
FEATURES
● Compact skid
● 1E quali cation and embedded safety related software
● Available under 10 CFR 50 App.B, ASME NQA-1 and
IEC 61226 programs for safety related applications
• Radioprotection of workers
○ Containment atmosphere
○ Control room air, etc.
• Post-accident operations (in combination with PIS
203S and NGM 203S)
○ Containment atmosphere
○ Reactor pressure vessel head leaks
○ Stacks, etc.
RELATED MONITORS
• PM 205S: particulate monitoring only
• IM 201S: iodine monitoring only
• NGM 216S: noble gas monitoring only
• PIS 203S: accident range particulate and iodine
sampler
• NGM 203S: high range noble gas monitor
• PING 206S: particulate, iodine and noble gas
monitor
radiation monitoring
systems
A Mirion Technologies Division
Featuring:
PING 207S
Combination Monitors
PHYSICAL CHARACTERISTICS
● Particulate (PM 205):
○ Radiation detected: beta
○ Detector: 2’’ thin plastic scintillator + PMT + embedded
LED
○ Filter type: berglass 49 mm (1.9 in)
○ Typical energy range: > 30 keV
○ Typical measurement range: 3.7 10
-12
(10
to 10-7 μCi/cc)
● Iodine (IM 201):
○ Radiation detected: gamma
○ Detector: 1¼”x1” NaI(TI) + PMT
○ Iodine cartridge: 57.7 mm (2.27 in)
○ Energy range: 100 keV to 3 MeV
○ Typical energy window: 314 - 414 keV (
○ 1024 channels spectrum
○ Typical measurement range: 3.7 to 3.7 10
-10
(10
to 10-4 μCi/cc)
● Noble gas (NGM 216):
○ Radiation detected: beta
○ Detector: 2’’ thin plastic scintillator + PMT + embedded
-2
to 3.7 10+3 Bq/m3
131
I, Eγ 364.5 keV)
+6
Bq/m3
LED
○ Typical energy range: > 30 keV
○ Typical measurement range: 3.7 10
+3
to 3.7 10+9 Bq/m3
(10-7 to 10-1 μCi/cc)
MECHANICAL CHARACTERISTICS
● Dimensions: provided on request
● Weight: provided on request
● Color: gray RAL 7030 (decontaminable paint)
● Inlet tube connection: Ø 25.4 mm OD (1 in)
● Outlet tube connection: Ø 12 mm OD (1/2 in)
ELECTRICAL CHARACTERISTICS
● Power supply: refer to possible versions
● Data link outputs: 1 RS232 and 5 isolated RS485
● Alarm relays: 9 SPDT relays and 5 DPDT relays
● I/O: 8 isolated analog outputs and 4 isolated analog
inputs (0/4-20 mA)
SIGNALING
● Graphic display: measurement, historical trend, status…
● Sound alarm: buzzer 90 dBA at 1 meter
● Visual alarm: 3 lights (red, yellow, green)
REFERENCE STANDARDS
● Nuclear: IEC60761, IEC61171, IEC61172, IEC61578
● Environmental: IEC60780, IEEE323
● Seismic: IEC60980, IEEE344
● EMC: 2006/95/CE and 2004/108/CE, EPRI 102323,
MIL STD 461 E, IEC61000-6-2 and IEC61000-6-4
ENVIRONMENTAL CHARACTERISTICS
● Long term temperature: +10°C to +40°C (+50°F to +104°F)
● Periodic temperature: -5°C to +55°C (+23°F to +131°F)
● MTBF: > 20 000 hours
● TID: 100 Gy (10
+4
rad)
PNEUMATIC CHARACTERISTICS
● Standard ow rate: 28.3 l/min (1 scfm)
● Pressure drop: 50 mbar (0.73 psi)
Mirion Technologies (MGPI) SA
Route d’Eyguières
FR-13113 Lamanon
France
T +33 (0) 4 90 59 59 59
F +33 (0) 4 90 59 55 18
Mirion Technologies (MGPI) Inc
5000 Highlands Parkway
Suite 150
Smyrna, GA 30082
USA
T +1 770 432 2744
F +1 770 432 9179
VERSIONS
● 230 Vac or 230 Vac + 400 Vac 3Ø or 120 Vac + 400 Vac 3Ø
● Solenoid check sources for PM 205, IM 201, NGM 216
● PIS particulate and iodine samplers
● Second pump for redundancy
ACCESSORIES
● Local & remote display units
● Calibration tools
● Software
● USB converters
www.mirion.com
153749EN-A
Mirion Technologies (MGPI H&B) GmbH
Landsberger Strasse 328a
DE-80687 Munich
Germany
T +49 (0) 89515 13-0
F +49 (0) 89515 13 169
Mirion Commercial (Beijing) Co., Ltd.
Shanghai Jiangchang Commercial Branch
Room 801, 78 Jiangchang SanLu
Zhabei District, Shanghai 200436
PR of China
T +86 21 6180 6920
F +86 21 6180 6924
Since norms, speci cations and designs are subject to occasional change, please ask for con rmation of the information given in this publication.