FEATURES
OEM Gamma Sensor
Area and Particulate Monitors - Area Monitor
OEM GAMMA SENSOR
Electronic Dosimeter Module
The OEM GAMMA SENSOR features  at energy 
response to X-rays and gammas from 50 keV to 7 MeV 
and a linear response for dose rate from natural 
background up to more than 10 Sv/h.
The OEM GAMMA SENSOR provides dose, dose rate, 
alarms, digital inputs (3) and digital ouputs (3)
 ● Slave mode: communication by I2C 
 or UART 9600 bauds
 ● Autonomous mode: essential parameters 
 sent periodically (1 to 63 seconds) on UART 4800 
 serial link
 ● Parameters and dose saved in EEPROM
health physics
A Mirion Technologies Division
Featuring:
 

OEM Gamma Sensor
Area and Particulate Monitors - Area Monitor
PHYSICAL CHARACTERISTICS
 ● Measurement range:  
 ○ Dose: 1 μSv to 10 Sv (0.1 mrem to 1000 rem) 
 ○ Dose rate: 10 μSv/h to 10 Sv/h (1 mrem/h to 1000 rem/h) 
 ○ For lower dose rate, please contact Mirion Technologies 
 ○ Saturation above 10 Sv or 10 Sv/h
 ● Linearity: 
 ○ <± 15% up to 1 Sv/h (100 rem/h) 
 ○ <± 25% up to 10 Sv/h (1000 rem/h) 
 ● X and Gamma energy range: 50 keV to 7 MeV
 ● Accuracy Hp(10) module alone:  
 ○ <±5% ( 
 ○ <±10% (
137
Cs : 1 mSv/h) (100 mrem/h)
241
Am: 0.2 mSv/h) (20 mrem/h)
ELECTRICAL CHARACTERISTICS
 ● 3.3V 1.2 mA for I2C mode, 0.4 mA for UART mode
MECHANICAL CHARACTERISTICS
 ● Dimensions:  
 ○ Ø: 40 mm (1.6 in) 
 ○ h: 4 mm (0.16 in)
 ● Weight: < 5.5 g (0.19 oz)
 ● LED fl ashing is programmable for:  
 ○ Each 4 or 8 pulses 
 ○ Each μSv (0.1 mrem) 
 ○ Each 10 μSv (1 mrem) 
 ○ Each 100 μSv (10 mrem)
 ● 2 Connectors: 
 ○ one for power supply, I2C or UART serial link, and 
alarm
 ○ one for digital inputs and outputs
CUSTOMIZATION
 ● Setup can be accessed by authorized user 
with OEMMASS software
ENVIRONMENTAL CHARACTERISTICS
 ● Temperature range: 
-10°C to +50°C (14°F to 122°F) 
 ● Storage: -30°C to +71°C (-22°F to 160°F)
 ● EMC: complies and exceeds standards by a large 
margin
FUNCTIONAL CHARACTERISTICS
 ● Alarm report output: 
 ○ no dose rate alarm or pre-alarm: 
 - alarm output signal normally low
 ○ dose rate «pre-alarm»: 
 - alarm output signal oscillates 0.5 Hz 
 ○ Dose rate alarm: alarm output signal goes high 
 ○ programmable threshold for dose rate pre-alarm and 
alarm
Health Physics
Health Physics 
Division
Division
www.mirion.com
144433EN-C
Mirion Technologies (MGPI) Inc 
5000 Highlands Parkway 
Suite 150 
Smyrna Georgia 30082 
Mirion Technologies (MGPI) SA
Lieu-dit Calès, route d’Eyguières
F-13113 Lamanon
France
Mirion Technologies (RADOS) Oy
P.O. Box 506 
FIN-20101 Turku
Finland
Mirion Technologies (RADOS) GmbH
Ruhrstrasse 49 
DE-22761 Hamburg
Germany
USA
T +1.770.432.2744 
F +1.770.432.9179
Since norms, specifi cations and designs are subject to occasional change, please ask for confi rmation of the information given in this publication.
T +33 4 90 59 59 59
F +33 4 90 59 55 18
T +358 2 468 4600 
F +358 2 468 4601
T +49 (0) 40 851 93-0 
F +49 (0)40 851 93 256
Mirion Technologies Shanghai Branch
Room 801, 78 Jiangchang 
San Lu, Zhabei District 
Shanghai 200436 
China
T +86 21 6180 6920 
F +86 21 6180 6924