Mirion Technologies NGM 203S User Manual

Featuring:
radiation monitoring systems
A Mirion Technologies Division
NGM 203S
Particulate, Gas & Iodine Monitors
NGM 203 S
The NGM 203S monitor forms part of the RAMSYS
product line.
It has been developed to sample air in discharge
stacks, ventilation ducts or working areas. A  ow
through ionization chamber is enclosed in a 4 π/5 cm
(4 π/2 in) lead shielding.
This monitor is designed to meet the noble gas
monitoring requirements set forth by the USA
Regulatory Guide 1.97 and it can be used before,
during and after an accident. It can operate in
conjunction with a shielded particulate and iodine
sampler (PIS 203) and with a low range noble gas
monitor (NGM 204) to form a wide range monitoring
system.
APPLICATIONS
• Post-accident operations
Containment atmosphere
Stacks, etc.
RELATED MONITORS
• PIS 203S: accident range particulate and iodine
sampler
FEATURES
Designed for accident and post-accident conditions
Durable detector without any electronic or radiation
degraded component
1E quali cation and embedded safety related software
Available under 10 CFR 50 App. B, ASME NQA-1 and
IEC61226 programs for safety related application
Since norms, speci cations and designs are subject to occasional change, please ask for con rmation of the information given in this publication.
Mirion Technologies (MGPI) SA
Route d’Eyguières FR-13113 Lamanon France
T +33 (0) 4 90 59 59 59 F +33 (0) 4 90 59 55 18
Mirion Technologies (MGPI) Inc
5000 Highlands Parkway Suite 150 Smyrna, GA 30082 USA T +1 770 432 2744 F +1 770 432 9179
Mirion Technologies (MGPI H&B) GmbH
Landsberger Strasse 328a DE-80687 Munich Germany
T +49 (0) 89515 13-0 F +49 (0) 89515 13 169
Mirion Commercial (Beijing) Co., Ltd.
Shanghai Jiangchang Commercial Branch
Room 801, 78 Jiangchang SanLu Zhabei District, Shanghai 200436 PR of China T +86 21 6180 6920 F +86 21 6180 6924
NGM 203S
Particulate, Gas & Iodine Monitors
PHYSICAL CHARACTERISTICS
Radiation detected: alpha, beta and gamma
Detector:  ow-through ionization chamber
Sensitive volume: 100 ml (100 cc)
Energy range: 5 keV to 3 MeV
Typical measurement range:
85
Kr: 3.7 10+6 to 10
+16
Bq/m3 (10-4 to 2.7 10+5 µCi/cc)
133
Xe: 10+6 to 3.7 10
+15
Bq/m3 (2.7 10-5 to 10+5 µCi/cc)
ENVIRONMENTAL CHARACTERISTICS
Long term temperature: +10°C to +40°C
(+50°F to +104°F)
Periodic temperature:
-5°C to +55°C (+23°F to +131°F)
MTBF: > 20 000 hours
TID (processing unit): 25 Gy (2.5 10
+3
rad)
PNEUMATIC CHARACTERISTICS
Standard  ow rate: 35 l/min (1.24 scfm)
Pressure drop: according to the  lter dust loading
MECHANICAL CHARACTERISTICS
Dimensions: 1305 mm x 830 mm x 680 mm
(51.4 in x 32.7 in x 26.8 in)
Weight: ~ 310 kg (~ 684 lb)
Color: gray RAL 7030 (decontaminable paint)
Inlet tube connection: Ø 12 mm OD (1/2 in)
Outlet tube connection: Ø 12 mm OD (1/2 in)
ELECTRICAL CHARACTERISTICS
Power supply: refer to possible versions
Data link outputs: 1 RS232 and 2 isolated RS485
Alarm relays: 3 SPDT relays
I/O: 2 isolated analog outputs (0/4-20 mA)
SIGNALING (Applicable to LPDU only)
Alphanumeric display: measurement, status…
Sound alarm: buzzer 90 dBA at 1 meter
Visual alarm: 3 lights (red, yellow, green)
REFERENCE STANDARDS
Nuclear: IEC60761
Environmental: IEC60780, IEEE323, RG 1.97
Seismic: IEC60980, IEEE344
EMC: 2006/95/CE and 2004/108/CE, EPRI 102323,
MIL STD 461 E, IEC61000-6-2 and IEC61000-6-4
VERSIONS
230 Vac or 230 Vac + 400 Vac 3Ø or 120 Vac
+ 400 Vac 3Ø
PIS sampler
Dust  lter holder
Gas grab sampler ports
Heater
ACCESSORIES
Local & remote display units
Calibration tools
Software
USB converters
www.mirion.com
144111EN-E
Loading...