Mirion Technologies M540 User Manual

FEATURES/BENEFITS
Coal Fired Utility Boilers•
Excellent image quality and depth of eld of the superheater tubes in the upper boiler.
Ash Hopper•
Allows the ash system operator to effectively monitor the behavior and trends of the build-up and the ow within the ash hopper.
IST-QUADTEK M540 LYNX
High Temperature Black and White IR Camera Series
The IST-Quadtek M540 series of near IR Black and
White High-Temperature Cameras is designed to give
lters and other options to provide continuous
monitoring of your process. Able to penetrate
gaseous and ne particulate interferences, these
cameras give a considerably improved image of
furnace, boiler, ash hoppers, or other processes.
Straight, oblique, or right angle lens tube options
are available to offer more exibility in mounting the
camera.
Bubbling Fluidized Bed Boilers•
Unique OAL lens gives plan view of bed with simple through-wall camera installation. Helps operator to recognize build-up of cake in the sand bed
imaging systems
A Mirion Technologies Division
Featuring:
?F
+
+
+
+
40
+
200
120
160
80
0
+
IN THE UK
PSHIRE
38
203
577
'L' - ACCORDING
TO LENS TYPE
261
203
293
IST-MODEL No
STD
ERIAL No
SPECIFICATIONS AND PERFORMANCE
CAMERA
Power Requirements 85-265 VAC, 47-440 Hz Camera Sensor Sensor Resolution >500 lines Video 1.0 V P-P, 75 ohm, CCTV signal
Control /AIR: Remote iris adjustment (with M721
1
/2” solid state image sensor
/VTE: EIA RS170 525 lines or /VTC: CCIR 625 lines
Remote Auto Iris Controller)
LENS
Construction Air or water cooled 304 stainless steel outer
shroud. Sapphire window for maximum environmental protection.
Lens Options /L: Straight view, /RAL: right angle with 90°
offset optics, /OAL: oblique angle with 45° offset optics, /WCL: water cooled
Lengths STD /L30: L=704mm (27.7”) or
/OAL30: L=678mm (26.7”) Other lenses available. Please contact your sales representative.
Field of View Wide: 75°H x 56°V
Medium: 55°H x 42°V Narrow: 35°H x 26°V
Diameter /L: 38mm (1.5”)
/RAL & /OAL: 51mm (2.0”) /WCL: 57mm (2.25”)
Cooling Requrements Instrument quality air, 12-19 dm
SCFM) @ 34 - 103 kPa (5-15 psig required for straight view lens (to ISO 8573-1, Class
1• 7• 2)
Environment 1621°C (2950°F) with proper cooling Thermocouple /TJ: Type J thermocouple option
/TK: Type K thermocouple option
3
/sec (25-40
ENCLOSURE
Construction /CEI: Corrosion-resistant, insulated, air-
cooled, NEMA 4; /CEW: Corrosion-resistant, water-cooled, NEMA 4
3
Cooling Type /CCV: Vortex cooling 13 dm
/sec @ 690 kPa (25 SCFM @ 100 PSI); Instrument quality air required.
Ambient Environment Max. 60°C (140°F) with negligible radiant
heat load. Water cooled option available to handle high radiant heat environment
MECHANICAL
Video Output Jack Female PL-259 “UHF” type Power Input Jack Removable waterproof miniplug (JOY type
TP, female 3-conductor; mating power cord provided)
1
Enclosure Cooling Input
Lens Cooling Input
Weight 30 pounds (14kg) for air-cooled congura-
/4” brass quick-disconnect nipple; mating
coupler (Snaptite BVHC4-4F) provided
1
/2” brass quick-disconnect nipple; mating
coupler (Snaptite BVHC8-8F) provided
tion (lens and camera)
200 IST Center Horseheads, NY 14845 USA T +1.607.562.4300 +1.800.432.1478 F +1.607.562.4392
© Copyright 2009. All rights reserved for trademark and registered trademark
information.
Station Road Alton, Hampshire GU34 2PZ, UK T 01420.541600 F 01420.541700
Kaiser-Konrad-Str 93a D 53225 Bonn Deutschland T 0228.625088 F 0228.626300
Quadtek® is a registered trademark of Mirion Technologies Corporation. The above specications may vary according to system conguration. Mirion Technologies Incorporated reserves the right to amend or change the information on this sheet without prior warning. 02/09
Loading...