Mirion Technologies KG 151 RBT-REZ User Manual

KG 151 RBT/REZ
Detectors
KG 151 RBT/REZ
Gamma Ionization Chamber
developed for low and medium range gamma dose
rate monitoring in nuclear facilities. Gamma radiation
produces charged particles (electrons and gas ions)
in the gas  lling the ionization chamber. Their dischar-
ge on the electrodes causes charge pulses. These
charge pulses are integrated to a DC current, which
can be measured in the external circuit.
The KG 151 RBT/REZ ionization chambers may be
connected to signal processing units of the RAMSYS
or TK 250 family.
FEATURES
Wide measuring range up to 100 Gy/h
Saturation proof
Robust construction
Long life time
Energy range: 80 keV to 3 MeV
Output signal: DC current starting at 0.1 pA
Ambient temperature up to 180°C (356°F)
APPLICATIONS
• Operational process monitoring
Measurement of low and medium dose rates for
process monitoring in nuclear facilities for harsh
environmental conditions
RELATED PRODUCTS
• KG 50/51 SEC: ionization chambers for high dose
rates
• TK 250: digital signal processing channels
• LPU/LPDU: RAMSYS signal processing units
radiation monitoring systems
A Mirion Technologies Division
Featuring:
KG 151 RBT/REZ
Detectors
TECHNICAL CHARACTERISTICS
Properties KG 151 RBT KG 151 REZ Tolerance Conditions
Measuring range 1e–7 Gy/h … 1 Gy/h
1 Gy/h … 1e+2 Gy/h
Sensitivity Energy range
Detector housing Gas  lling Embedded source
Operating voltage Break down voltage Detector source current
Temperature range Short term temperature range External pressure Humidity
Length of detector Total length Diameter Sensitive volume Weight (without connector and cable)
2e–6 A/(Gy/h) 80 keV … 3 MeV
Steel Argon, 26 bar Cs-137, 185 kBq
1200 VDC, typ. 2500 VDC 1e-12 A approx.
0 … 150°C (0 ... 302°F) < 180°C (356°F)
0.7 … 1.3 bar < 95%
502 mm (19.7 in) 595 mm (23.4 in) 150 mm (5.9 in)
5.7 l Approx. 12.5 kg (27.5 lb)
Connectors Fischer size 105 Fischer size 105 Max. cable length is depending on signal pro-
1e–7 Gy/h … 1 Gy/h 1 Gy/h … 1e+2 Gy/h
2.23e–6 A/(Gy/h) 80 keV … 3 MeV
Stainless steel Argon, 26 bar Cs-137, 185 kBq
1200 VDC, typ. 2500 VDC 1e-12 A approx.
-25 … 150°C (-13 ... 302°F) < 180°C (356°F)
0.7 … 1.3 bar < 95%
502 mm (19.7 in) 602 mm (23.7 in) 150 mm (5.9 in)
5.7 l Approx. 14 kg (30.8 lb)
± 20% acceptable deviation of sensitivity ± 40 % acceptable deviation of sensitivity
± 10% ± 40% acceptable deviation of sensitivity (KTA
1501)
± 5% 10 s max. With embedded source
1 h max.
cessing unit (cable capacity)
ACCESSORIES
Assembly kit with insulated clamps
TKS 01: cable protection unit for LOCA-proof
installation of KG 151 REZ
TKA 66.11: calibration source Cs-137, remote
operated
Connection cables: low noise cable, e.g. Raychem
5021B or Gore GCX 0157
Digital signal processing units: TK 250 system: e.g. DPK 251 digital signal
processing channel with c/f-converter NV 103
RAMSYS system: LPU-IC or LPDU-IC local signal
processing units
Mirion Technologies (MGPI) SA
Route d’Eyguières FR-13113 Lamanon France
T +33 (0) 4 90 59 59 59 F +33 (0) 4 90 59 55 18
Mirion Technologies (MGPI) Inc
5000 Highlands Parkway Suite 150 Smyrna, GA 30082 USA T +1 770 432 2744 F +1 770 432 9179
Mirion Technologies (MGPI H&B) GmbH
Landsberger Strasse 328a DE-80687 Munich Germany
T +49 (0) 89515 13-0 F +49 (0) 89515 13 169
www.mirion.com
144976EN-D
Mirion Commercial (Beijing) Co., Ltd. Shanghai Jiangchang Commercial Branch
Room 801, 78 Jiangchang SanLu Zhabei District, Shanghai 200436 PR of China T +86 21 6180 6920 F +86 21 6180 6924
Since norms, speci cations and designs are subject to occasional change, please ask for con rmation of the information given in this publication.