Mirion Technologies IST R90 User Manual

IST R90 Series Cables and Connectors are designed for use with all of the R90 Series nuclear cameras and have been specifically developed for nuclear applications underwater or in air.
All the IST R90 Series cameras have a very high radiation tol­erance which is partly achieved by their dual unit construction with the majority of the camera electronics being contained in a separate camera control unit (CCU) outside the active area. This design approach reduces radiation damage, while also ensuring easy service access. The CCU’s are linked to their associated cameras by single composite camera cables - with matching connectors - which provide all the necessary power, control and signal functions.
Rees Minikevlar 102.00.042
Features
• Air and underwater appplications
• Radiation tolerant
• Wide range
• Specifically developed for nuclear operations
• Site reterminable connectors
• Field proven design
31 core camera cable with kevlar strength member, XLPE cores, and polyure­thane elastomer jacket.
Cores
2 coaxials 75 ohm
1 screened quad (7 x 0.2mm) <.008”>
2 groups of 7 (each 7 x 0.2mm)
1 group of 5 (each 7 x 0.2mm)
3 singles (each 7 x 0.2mm)
3 earth returns (each 16 x 0.2mm)
Mechanical
Diameter ...............................................11.30mm <.44”> (±0.38mm)
(<.015”>
Installation bend radius ........................82mm min (3.2”)
Continuous flexing bend radius.............165mm min (6.5”)
Weight in air .........................................170g/m (.44 lb/yd)
Break strength .......................................324kg (714 lb)
Operating temp.range ...........................-20° to 70°C (-4°F to 158°F)
Total radiation dose .............................106 Gy (108 rads)
Electrical
75 ohm coaxial:
Characteristic impedance .....................75 ± 2 ohms
Attenuation ...........................................5.7 dB per 100m (328’) at 10 MHz
XLPE Insulated Cores:
dc resistance .........................................8.8 ohms per 100m (328’) nominal
Earth returns:
dc resistance .........................................4.0 ohms per 100m (328’) nominal
Imaging & Sensing Technology Corporation
TV36 102.00.019
R90 Series Cables
36 core camera cable with kevlar braid, XLPE cores and polyurethane jacket.
Cores
3 coaxials 75 ohm
1 group of 14 (each 7 x 0.16mm) <.006”>
1 screened group of 7 (each 7 x 0.16mm)
1 group of 4 (each 7 x 0.16mm)
1 screened group of 4 (each 7 x 0.32mm) <.012”>
4 singles (each 7 x 0.23mm) <.009”>
Rees Minicable R000CAB014
A special 31 core camera cable with a very small diameter and bend radius, polyester tape cores and polyester elastomer jacket.
Mechanical
Diameter................................................16.45mm <.65”> (max
16.90mm<.66”>)
Break strength .......................................1000 kg (2205 lb)
Minimum Installation bend radius ........100mm (4”)
Continuous flexing bend radius ............240mm (9.5”)
Weight in air .........................................0.34kg/m (.75 lb /yd)
Operating temp. range ..........................-20° to 80°C (-4°F to 176°F)
Total radiation dose ..............................106 Gy (108 rads)
Electrical
75 ohm coaxial:
Characteristic Impedance .....................75 ohms
Attenuation ...........................................4.7 dB per 100m at 10 MHz
Insulated Cores .....................................dc resistance at 20°C (68°F)
7 x 0.32 ..................................................3.59 ohms per 100 m (328’)
7 x 0.23 ..................................................6.83 ohms per 100 m (328’)
7 x 0.16 ..................................................14.4 ohms per 100 m max (328’)
Mechanical
Diameter................................................8.8mm <.35”>(±0.6mm) <0.2”>
Installation bend radius ........................ 45mm min.(1.8”)
Continuous fllexing bend radius ...........90mm (3.5”)
Weight in air .........................................0.14kg/m (0.3lb/yd)
Operating temp. range .........................-20° to 80°C (-4°F to 176°F)
Total radiation dose ..............................106 Gy (108 rads)
Cores
2 coaxials 75 ohm
1 screened quad (7 x 0.2mm) <.008”>
21 singles (each 7 x 0.2mm)
3 singles (each 19 x 0.2mm)
Electrical
75 ohm coaxials:
Characteristic impedance ....................75 ohm ± 2 ohms
Attenuation ...........................................5.7 dB per 100m (328’) at 10 MHz
Polyester Tape Insulated cores .............dc resistance at 20°C (68°F)
7 x 0.2mm ..............................................8.8 ohms per 100m (328’)
19 x 0.2mm ............................................3.2 ohms per 100m (328’)