Mirion Technologies GMP-12H-3 User Manual

health physics
A Mirion Technologies Division
GMP-12-3/12H-3 /12L-3 External Probes
Portable Survey Meters
FEATURES
compatible with RADOS RDS-31 survey meter• remote dose rate measurements• optional telescopic rod• GMP-12H extends measurement range of RDS-110• cord lengths up to 15 meters upon request
External Gamma Probes
These External Probes enhance the detection
capability of the RDS-31 survey meter.
The GMP-12-3, GMP-12H-3 and GMP-12L-3 probes
are intended for monitoring gamma and X-ray
radiation.
They have been designed to ful ll both the civil de-
fense and industrial applications requirements.
www.mirion.com
Mirion Technologies (MGPI) Inc 5000 Highlands Parkway Suite 150 Smyrna Georgia 30082 USA T +1.770.432.2744 F +1.770.432.9179
Mirion Technologies (MGPI) SA
BP 1 F-13113 Lamanon France T +33 (0) 4 90 59 59 59 F +33 (0) 4 90 59 55 18
Mirion Technologies (RADOS) Oy
P.O. Box 506 FIN-20101 Turku Finland T +358 2 4684 600 F +358 2 4684 601
Mirion Technologies (RADOS) GmbH
Ruhrstrasse 49 D-22761 Hamburg Germany T +49 40 85193 0 F +49 40 85193 256
GMP12-3/12H-3/12L-3 External Probes
Portable Survey Meters
20996375_GMP12-3_12H-3_12L-3_EN_A
TECHNICAL SPECIFICATIONS:
GMP-12-3 External High Dose Rate Gamma Probe
radiation detected: gamma and x-rays, according to ambient dose equivalent H*(10).
energy range: 50 keV - 3 MeV for dose rate range 0.05 µSv/h - 10 mSv/h, and • 80 keV - 3 MeV for dose rate range 10 mSv/h - 10 Sv/h.• detector type: two halogen quenched, energy compensated GM tubes (types ZP 1202 and ZP 1304 • or equivalent). dose measurement range: 0.01 µSv - 10 Sv.• dose rate measurement range: 0.05 Sv/h – 10 Sv/h.• Calibration accuracy: 5% of the reading in 3 mSv/h Cs-137 exposure at +20C.• energy response: -20% … +30% over energy range 80 keV - 1.25 MeV,• also the same over energy range 50-80 keV when dose rate below 10 mSv/h,• (+95% at 6 MeV).• temperature range: Operation: -40°C to +55°C.• storage: -40°C to +70°C.• enclosure class IP 67 (short term).• dimensions: Length 185 mm, cylinder diameter 45 mm.• weight: 400 g.
GMP-12 H-3 External High Dose Rate Gamma Probe
radiation detected: gamma and x-rays, according to ambient dose equivalent H*(10)• energy range: 80 keV - 1.3 MeV• detector type: halogen quenched, energy compensated GM tube (type ZP 1304 or equivalent)• dose measurement range*: 1 μSv – 10 Sv• dose rate measurement range*: 0.1 mSv/h – 10 Sv/h• calibration accuracy: ±5% of the reading in 3 mSv/h
137
Cs exposure at +20°C (68°F) energy response: ±15% over energy range 80 keV – 1.3 MeV, (+95% at 6 MeV)• temperature range: operation: -40°C to +55°C (-40 to 131°F) storage: -40°C to +70°C (-40 to 158°F) • dimensions: length 185 mm (7.28 in), cylinder diameter 45 mm (1.77 in)• weight: 370 g (0.81 lb),standard cord lenght 2 m ( 78,74 in)
GMP-12 L-3 External Low Dose Rate Gamma Probe
radiation detected: gamma and x-rays, according to ambient dose equivalent H*(10)• energy range: 50 keV - 1.3 MeV• detector type: halogen quenched, energy compensated GM tube (type ZP 1202 or equivalent)• dose measurement range: 0.01 μSv - 10 Sv• dose rate measurement range*: 0.05 μSv/h – 100 mSv/h• calibration accuracy: ± 5% of the reading in 300 μSv/h
137
Cs exposure at +20°C (68°F) energy response: ±30% over energy range 50 keV - 1.3 MeV, (+95% at 6MeV)• temperature range: operation: -40°C to +55°C (-40°F to 131°F); storage: -40°C to +70°C (-40°F to • 158°F) dimensions: length 185 mm (7.28 in), cylinder diameter 45 mm (1.77 in)• weight: 380 g (0.83 lb), standard cord lenght 2 m ( 78,74 in)