Mirion Technologies GMP-12H-12L User Manual

GMP-12H & GMP-12L External Probes
Portable Survey Meters
External Probes
These External Probes enhance the detection capability of the RADOS RDS-110 and RDS-200 survey meters. They have been designed to ful ll both the civil defense and industrial applications requirements.
The GMP-12H and GMP-12L probes are intended for monitoring gamma and X-ray radiation. They can be used as external probes for the RDS-110 and RDS-200 Survey Meters. The GMP-12H and GMP-12L probes are connected to an external 6-pin lockable connector interface at the bottom of the RDS­meters.
FEATURES
compatible with RADOS RDS-110 & RDS-200 survey • meters remote dose rate measurements• optional telescopic rod• GMP-12H extends measurement range of RDS-110• cord lengths up to 15 meters upon request
All the probes can be used as hand-held or as  xed probes
health physics
A Mirion Technologies Division
Featuring:
TECHNICAL SPECIFICATIONS:
GMP-12 H External High Dose Rate Gamma Probe
radiation detected: gamma and x-rays, according to ambient dose equivalent • H*(10) energy range: 80 keV - 1.3 MeV• detector type: halogen quenched, energy compensated GM tube (type ZP 1304 or • equivalent) dose measurement range*: 1 μSv – 10 Sv• dose rate measurement range*: 0.1 mSv/h – 10 Sv/h• calibration accuracy: ±5% of the reading in 3 mSv/h • (68°F) energy response: ±15% over energy range 80 keV – 1.3 MeV, (+95% at 6 MeV)• temperature range: operation: -40°C to +55°C (-40 to 131°F) storage: -40°C to • +70°C (-40 to 158°F) dimensions: length 185 mm (7.28 in), cylinder diameter 45 mm (1.77 in)• weight: 370 g (0.81 lb),standard cord lenght 2 m ( 78,74 in)• * RDS-110 displays dose only up to 1 Sv
GMP-12 L External Low Dose Rate Gamma Probe
radiation detected: gamma and x-rays, according to ambient dose equivalent • H*(10) energy range: 50 keV - 1.3 MeV• detector type: halogen quenched, energy compensated GM tube (type ZP 1202 • or equivalent) dose measurement range: 0.01 μSv - 10 Sv• dose rate measurement range*: 0.05 μSv/h – 100 mSv/h• calibration accuracy: ± 5% of the reading in 300 μSv/h • (68°F) energy response: ±30% over energy range 50 keV - 1.3 MeV, (+95% at 6MeV)• temperature range: operation: -40°C to +55°C (-40°F to 131°F); storage: -40°C • to +70°C (-40°F to 158°F) dimensions: length 185 mm (7.28 in), cylinder diameter 45 mm (1.77 in)• weight: 380 g (0.83 lb), standard cord lenght 2 m ( 78,74 in)
GMP12H & 12L External Probes
Portable Survey Meters
137
Cs exposure at +20°C
137
Cs exposure at +20°C
MGP Instruments Inc 5000 Highlands Parkway Suite 150 Smyrna Georgia 30082 USA T +1.770.432.2744 F +1.770.432.9179
MGP Instruments SA
BP 1 F-13113 Lamanon France T +33 (0) 4 90 59 59 59 F +33 (0) 4 90 59 55 18
RADOS Technology Oy
P.O. Box 506 FIN-20101 Turku Finland T +358 2 4684 600 F +358 2 4684 601
www.mirion.com
20996038_GMP12H_12L_EN_A
RADOS Technology GmbH
Ruhrstrasse 49 D-22761 Hamburg Germany T +49 40 85193 0 F +49 40 85193 256
Loading...