Mirion Technologies GIM 210K User Manual

Featuring:
radiation monitoring systems
A Mirion Technologies Division
GIM 210K
Gamma & Neutronic Monitors
GIM 210K
The GIM 210K forms part of the RAMSYS product
line. It has been developed to monitor dose rate or
equivalent dose rate in nuclear facilities.
It can manage simultaneously two separated detec-
tors, either two SG/GM21, two SG/GM22 or one SG/
GM21 + one SG/GM22.
APPLICATIONS
• Radioprotection of workers
• Operational process monitoring
Gamma interlock, etc.
RELATED MONITORS
• GIM 207K: low range version
(with SG/GM 21 detector)
• GIM 208K: high range monitor
(with SG/GM 22 detector)
• GIM 209K: wide range version
(with SG/GM 23 detector)
FEATURES
Wide temperature range detector
Compact and reliable
Available with or without display and local signaling
Small diameter detector
Up to 200 m (650 ft) between GM detectors and
processing unit
Measurement in Gy/h (rad/h) or Sv/h (rem/h)
Since norms, speci cations and designs are subject to occasional change, please ask for con rmation of the information given in this publication.
Mirion Technologies (MGPI) SA
Route d’Eyguières FR-13113 Lamanon France
T +33 (0) 4 90 59 59 59 F +33 (0) 4 90 59 55 18
Mirion Technologies (MGPI) Inc
5000 Highlands Parkway Suite 150 Smyrna, GA 30082 USA T +1 770 432 2744 F +1 770 432 9179
Mirion Technologies (MGPI H&B) GmbH
Landsberger Strasse 328a DE-80687 Munich Germany
T +49 (0) 89515 13-0 F +49 (0) 89515 13 169
Mirion Commercial (Beijing) Co., Ltd.
Shanghai Jiangchang Commercial Branch
Room 801, 78 Jiangchang SanLu Zhabei District, Shanghai 200436 PR of China T +86 21 6180 6920 F +86 21 6180 6924
GIM 210K
Gamma & Neutronic Monitors
PHYSICAL CHARACTERISTICS
Radiation detected: gamma
Detector: Geiger Muller tubes
Energy range: 80 keV to 2 MeV
Typical measurement range: With two SG/GM 21 detectors:
10-6 to 10-3 Gy/h (10-4 to 10-1 rad/h)
With two SG/GM 22 detectors:
10-4 to 1 Gy/h (10-2 to 10+2 rad/h)
With one SG/GM 21 and one SG/GM 22 detector:
10-6 to 1 Gy/h (10-4 to 10+2 rad/h)
ENVIRONMENTAL CHARACTERISTICS
Long term temperature:
+10°C to +40°C (+50°F to +104°F)
Periodic temperature (processing unit):
-5°C to +55°C (+23°F to +131°F)
Periodic temperature (detector):
-40°C to +70°C (-40°F to +158°F)
MTBF: > 20 000 hours
TID (processing unit): 100 Gy (10
+4
rad)
TID (SG/GM 21 detector): 6 Gy (6 10
+2
rad)
TID (SG/GM 22 detector): 370 Gy (3.7 10
+4
rad)
Protection index: IP65 and IK07
MECHANICAL CHARACTERISTICS
Dimensions: Processing unit: 390 mm x 196 mm x 187 mm
(15.3 in x 7.7 in x 7.3 in)
Detector: 184 mm (7.2 in) x Ø 28 mm (1.1 in)
Weight: Processing unit: 8.5 kg (18.7 lb)Detector: 470 g (1 lb)
Color (processing unit): gray RAL 7030 (decontamina-
ble paint)
ELECTRICAL CHARACTERISTICS
Power supply: 230 Vac – 50 Hz or 120 Vac – 60 Hz
Data link outputs: 1 RS232 and 2 isolated RS485
Alarm relays: 3 SPDT relays
I/O: 2 isolated analog outputs and 1 isolated analog
input (0/4-20 mA)
SIGNALING (Applicable to LPDU only)
Alphanumeric display: measurement, status…
Sound alarm: buzzer 90 dBA at 1 meter
Visual alarm: 3 lights (red, yellow, green)
REFERENCE STANDARDS
Nuclear: IEC60532
Seismic: IEEE344 and IEC60980
EMC: 2006/95/CE and 2004/108/CE, EPRI 102323,
MIL STD 461 E, IEC61000-6-2 and IEC61000-6-4
VERSIONS
230 Vac or 120 Vac
LPDU or LPU
With or without RS485 junction box
Detector cable length:
from 10 m (32.8 ft) to 200 m (656 ft)
Junction box cable length:
2 m (6.56 ft), 5 m (16.4 ft) or 10 m (32.8 ft)
Detector calibrated in Gy/h or Sv/h
ACCESSORIES
Calibration tools
Software
USB converters
Seismic quali ed wall mounting bracket
www.mirion.com
144377EN-E
Loading...