Mirion Technologies GIM 203K User Manual

Featuring:
radiation monitoring systems
A Mirion Technologies Division
GIM 203K
Gamma & Neutronic Monitors
GIM 203K
The GIM 203K forms part of the RAMSYS product
line. It has been developed to continuously monitor
gamma dose rate under harsh environment condi-
tions. It is particularly useful for monitoring the dose
rate inside containment and in the reactor building
during and after mild and severe accidents under
harsh operating conditions.
APPLICATIONS
• Radioprotection of workers
Containment atmosphere, etc.
• Post-accident operations
RELATED MONITORS
• GIM 201K: low range gamma area monitor
• GIM 202K: wide range gamma area monitor
• GIM 205K: medium range gamma area monitor
• GIM 206K: high range gamma area monitor
FEATURES
Wide measurement range
Compact and reliable
Available with or without display and local signalling
1E quali cation and embedded safety related software
Available under 10 CFR 50 App.B, ASME NQA-1 and
IEC61226 programs for safety related applications
LOCA proof detector and cable
Very high TID
Seismic quali cation
Since norms, speci cations and designs are subject to occasional change, please ask for con rmation of the information given in this publication.
Mirion Technologies (MGPI) SA
Route d’Eyguières FR-13113 Lamanon France
T +33 (0) 4 90 59 59 59 F +33 (0) 4 90 59 55 18
Mirion Technologies (MGPI) Inc
5000 Highlands Parkway Suite 150 Smyrna, GA 30082 USA T +1 770 432 2744 F +1 770 432 9179
Mirion Technologies (MGPI H&B) GmbH
Landsberger Strasse 328a DE-80687 Munich Germany
T +49 (0) 89515 13-0 F +49 (0) 89515 13 169
Mirion Commercial (Beijing) Co., Ltd.
Shanghai Jiangchang Commercial Branch
Room 801, 78 Jiangchang SanLu Zhabei District, Shanghai 200436 PR of China T +86 21 6180 6920 F +86 21 6180 6924
GIM 203K
Gamma & Neutronic Monitors
PHYSICAL CHARACTERISTICS
Radiation detected: gamma
Detector: stainless steel ionization chamber
(KG 221 SER)
Energy range: 80 keV to 7 MeV
Typical measurement range: 10
-6
to 10+3 Sv/h
(10-4 to 10+5 rem/h)
ENVIRONMENTAL CHARACTERISTICS
Long term temperature: +10°C to +40°C
(+50°F to +104°F)
Periodic temperature (processing unit): -5°C to +55°C
(+23°F to +131°F)
Periodic temperature (detector): +165°C (329°F) during 12 hours+225°C (437°F) for accident conditions
MTBF: > 20 000 hours
TID:Processing unit: 25 Gy (2.5 10
+3
rad)
Detector: 2 10
+6
Gy (2 10+8 rad)
Protection index:Processing unit: IP65 and IK07Detector: IP67 and IK07
MECHANICAL CHARACTERISTICS
Dimensions: Processing unit:
390 mm x 196 mm x 187 mm (15.3 in x 7.7 in x 7.3 in)
Detector: 240 mm (9.5 in) x Ø 280 mm (11 in)
Weight: Processing unit: 8.5 kg (18.7 lb)Detector: 24 kg (53 lb)
Color: gray RAL 7030 (decontaminable paint)
ELECTRICAL CHARACTERISTICS
Power supply: 230 Vac – 50 Hz or 120 Vac – 60 Hz
Data link outputs: 1 RS232 and 2 isolated RS485
Alarm relays: 3 SPDT relays
I/O: 2 isolated analog outputs and 1 isolated analog
input (0/4-20 mA)
SIGNALING (Applicable to LPDU only)
Alphanumeric display: measurement, status…
Sound alarm: buzzer 90 dBA at 1 meter
Visual alarm: 3 lights (red, yellow, green)
REFERENCE STANDARDS
Nuclear: IEC60951 and IEC60532
Environmental: IEEE323 and IEC60780, including
LOCA test, RG 1.97
Seismic: IEEE344 and IEC60980
EMC: 2006/95/CE and 2004/108/CE, EPRI 102323,
MIL STD 461 E, IEC61000-6-2 and IEC61000-6-4
VERSIONS
230 Vac or 120 Vac
LPDU or LPU
With or without RS485 junction box
Mineral or organic detector cable
Detector cable length: from 10 m (32.8 ft)
to 70 m (229.6 ft); length up to 140 m (459.3 ft) is also possible, by means of two sets of mineral extension cables
Junction box cable length: 2 m (5.65 ft), 5 m (16.4 ft)
or 10 m (32.8 ft)
ACCESSORIES
Calibration tools
Software
USB converters
Seismic quali ed wall mounting bracket
www.mirion.com
144303EN-F