FEATURES
direct measurement of H*(10) over the • entire energy range instant non-destructive readout and dose reset • with a table-top reader passive operation• insensitive to EM and RF interference• operation at high dose rates and in pulsed  elds• built-in memory chip for measurement • location identi cation storage small, rugged and waterproof• a replacement to TLD and  lm• up to 12 month issue period
EDIS-1
Environmental Direct Ion Storage Dosimeter
The new RADOS EDIS-1 is an Environmen-
tal Direct Ion Storage Dosimeter o ering an
alternative to TLD or  lm dosimeter.
The EDIS-1 dosimeter is based on an ionisation
chamber combined with a modern electronic
Direct Ion Storage (DIS) memory cell. The Ion
chamber is widely used as a reference detec-
tor in radiation detection and is now available in
everyday dosimetry applications. The EDIS-1
dosimeter can be read in nitely and non-
destructively without any loss of dose informa-
tion. This unique feature allows the user of the
EDIS-1 to instantly read environmental doses
whenever necessary.
The radiological range of the EDIS-1 covers the
entire H*(10) photon energies without any com-
promises. The wide dose and energy range, the
ability to operate in pulsed  elds and the perfor-
mance at high dose rates make EDIS-1 an ideal
device for all kinds of radiation dosimetry appli-
cations. The EDIS-1 allows for the detection of
heavy, high-energy ions and its immunity to any
external interference is unequalled. There are no
deviations in the dose readings even at very high
EM or RF  elds.
The excellent radiological features and the easy
and fast reading of the EDIS-1 dosimeter makes
the new DIS based RADOS dosimetry system
superior to any Film dosimetry or TLD system
without the need for complicated processing
systems.
Page 2
www.mirion.com
Mirion Technologies (MGPI) Inc 5000 Highlands Parkway Suite 150 Smyrna Georgia 30082 USA T +1.770.432.2744 F +1.770.432.9179
Mirion Technologies (MGPI) SA
BP 1 F-13113 Lamanon France T +33 (0) 4 90 59 59 59 F +33 (0) 4 90 59 55 18
Mirion Technologies (RADOS) Oy
P.O. Box 506 FIN-20101 Turku Finland T +358 2 4684 600 F +358 2 4684 601
Mirion Technologies (RADOS) GmbH
Ruhrstrasse 49 D-22761 Hamburg Germany T +49 40 85193 0 F +49 40 85193 256
EDIS-1 Environmental Direct Ion Storage Dosimeter
Passive Dosimetry
20996030_EDIS1_EN_B
TECHNICAL SPECIFICATIONS:
Physical Characteristics
detector type: three
TM
DIS (Direct Ion Storage) detectors and two MOSFET detectors sensitive to gamma and X-ray radiation• insensitive to neutrons (<5 %)
instant readout of ICRU dose equivalents: H*(10) 1 μSv to 40 Sv (0.1 mrem to 4000 rem)
1)
calibration accuracy: ±5 % at 1 mSv
137
Cs H*(10) energy response in the dose range up to 1 Sv: • photons
- H*(10) ±30 % from 15 keV to 9 MeV
angular response: H*(10) ±20 % up to 60° at 65 keV
1)
When calibrated after every 10 Sv of accumulated dose
Functional Characteristics
recording of o cial H*(10) dose• memory:
- calibration date
- dose reset dates
- location ID and name
Mechanical Characteristics
size: 41 x 44 x 12 mm, with holder 47 (95 with strap) x 49 x 13 mm (1.61 x 1.73 x 0.47 in , with • holder 1.85 (3.74 with strap) x 1.93 x 0.51 in) weight (w/o holder): 25 g (0.88 oz) • holder: anodized aluminium
Environmental Characteristics
temperature range from - 25°C to +50 °C ( 13 °F to 122 °F)• enclosure class: IP 67 (waterproof)
The DBR-1 and DBR-2 Readers are designed to read EDIS-1 Dosimeters assembled in the DDH-E Snap-in Dosimeter Holders. To ob­tain the most recent dose value, the user simply plugs the dosimeter into the reader and the dose values are diplayed in a few seconds.
Typical energy response of ambient dose equivalent H*(10) of less sensitive element.
Typical energy response of ambient dose equivalent H*(10) of more sensitive element