Mirion Technologies DOSIDEF User Manual

DOSIDEF
Active Dosimetry - Software
DOSIDEF
Management Software for Military Dosimetry
DOSIDEF is a software architecture system designed
dosimetry of all the exposed military personal even
when deployed.
DOSIDEF is used to record in a chronological manner
all the individual doses and to check the compliance
with the of cial dose limits.
RELATED PRODUCTS
FEATURES
Data collection from remote XOM readers or
DOSIXOM  les
Individual dose history reconstruction
Time stamp synchronization
Comparison with legal alarm levels
Remote access to the database
Modular architecture
SOR/T and SOR/R
XOM/T and XOM/R
DOSIXOM software (version 2)
health physics
A Mirion Technologies Division
Featuring:
DOSIDEF
Active Dosimetry - Software
SYSTEM ARCHITECTURE
DOSIDEF_ACQUISITION module for data collection
DOSIDEF_ACCESS module for restricted access to the central database DOSIDEF_CALC module for the dose calculation and the database management The 3 modules can be operated separately or on the same PC
DOSIDEF_ACQUISITION MODULE
Data collection from deployed XOM readers or DOSIXOM  les Data transfer to the server Local data enrichment (mission de nition) Local and UTC time management for synchronizing readers Local back-up Populate reader with pre-allocation lists
DOSIDEF_CALCULATION MODULE
SYSTEM CONFIGURATION
PC-based con guration for clients
Server size depends on population Operates with Windows 98, 2000, XP Compatible with ORACLE® and SQL_server® data bases (not included)
Collected data analyzed prior to integration in the data- base Rebuilds chronology, detects and solves any problem due to missing data or erroneous sequence of events Residual, gamma  ash and neutron  ash doses management Evaluation of the daily dose exposure and duration Raw and net doses calculation Background compensation capability Dose compared with the preset limit thresholds
DOSIDEF_ACCESS MODULE
Administrative data management and display of the dosimetry for individuals, cells, units or missions Display all events occured on the  led (readings) Alarms and exceeded limits sorting Data enrichment capability XOM pre-allocation lists managment Access to the dosimeter database for maintenance purposes Large choice of built-in reports
Health Physics Division
Mirion Technologies (MGPI) Inc
5000 Highlands Parkway Suite 150 Smyrna Georgia 30082 USA T +1.770.432.2744 F +1.770.432.9179
Since norms, specifi cations and designs are subject to occasional change, please ask for confi rmation of the information given in this publication.
Mirion Technologies (MGPI) SA
BP 1 F-13113 Lamanon France
T +33 (0) 4 90 59 59 59 F +33 (0) 4 90 59 55 18
Mirion Technologies (RADOS) Oy
P.O. Box 506 FIN-20101 Turku Finland
T +358 2 468 4600 F +358 2 468 4601
Mirion Technolgies (RADOS) GmbH
Ruhrstrasse 49 DE-22761 Hamburg Germany
T +49 (0) 40 851 93-0 F +49 (0)40 851 93 256