Mirion Technologies DMC 2000S User Manual

FEATURES
The DMC 2000S featured display of dose, dose rate and
programmable alarms. The DMC 2000S is user friendly,
lightweight and waterproof.
Stand-alone device or integrated into a dosimetry
system
Audible and visual alarms
Large internal histogram memory
Self-testing diagnostics (battery, detector and
parameters)
Hand free communication, pass-by exchange
Optional teledosimetry or use as an area monitor
DMC 2000S
Active Dosimetry - Dosimeters
DMC 2000S
Personal Electronic Dosimeter
The DMC 2000S features  at energy response to X-rays
response to dose rate  elds from natural background
up to more than 10 Sv/h.
The pass-by data exchange feature gives unequal
operational  exibility. In-motion reading allows dose
management by sub-zone as well as real-time location
tracking of personnel.
RELATED PRODUCTS
MGP Instruments offers a range of products which can
be used with the DMC 2000 S to create integrated
dosimetry systems including:
LDM 220, LDM 230 proximity readers
LDM 2000 pass-by data exchange
DOSISERV dosimetry centralization and access
control software
DOSIMASS dosimeter con guration software
DOSICARE and DOSIFAST operational dosimetry
software
IRD 2000 irradiator for dosimeters
health physics
A Mirion Technologies Division
Featuring:
PHYSICAL CHARACTERISTICS
Compliant to IEC 1283, ANSI 4220A PTB approved version, compliant with IEC61526 ed2
Measurement and display:
display units: mSv, μSv or mrem dose: 1 μSv to 10 Sv (0.1 mrem to 1000 rem) display rate: 0.01 mSv/h to 10 Sv/h or 0.001 mSv/h to 10 Sv/h (extended option) measurement range: 0.1 μSv/h to 10 Sv/h Linearity: <± 20 % up to 1 Sv/h (100 rem/h) <± 30 % up to 10 Sv/h (1000 rem/h) X and gamma energy range: 50 keV to 6 MeV Accuracy: <± 10 % (
137
Cs, ~ 25 mSv/h including ± 5 %
extended uncertainty K=2)
ELECTRICAL CHARACTERISTICS
DMC 2000S
Active Dosimetry - Dosimeters
The histogram enables events to be reconstructed in detail. Radiological supervisors can then analyze the data surroun­ding an incident.
Standard calculator battery LiMnO
CR2450, one year
2
battery life (typical, 8h per day in run mode)
MECHANICAL CHARACTERISTICS
Dimensions: 87 x 48 x 28 mm (3.4 x 1.9 x 1.1 in) with clip Weight with battery: < 56 g (1.9 oz) Worn by a replacable clip
ENVIRONMENTAL CHARACTERISTICS
Temperature range: -10°C to 50°C (14°F to 122°F) Humidity: < 90 % at 42°C (108°F) Storage: -30°C to 71°C (-22°F to 160°F) Shock, vibration and drop resistant, waterproof IP67
EMC: complies and exceeds standards by a large margin
Factory calibration approved under ISO/CEI 17025
Hp
Dose rate display
Accumulated dose display
Histogram are saved to non-volatile memory (EEPROM) workers dose stored in increments of 10 s, 1 min,10 min or 24 hours with compression of consecutive zero dose intervals Event log (alarms, faults, changes) marks events during the selected time period Time and data of passage with sub-zone notation Stores data for several consecutive workers’ entries and exits (up to 700 steps version 2 and up to 3800 steps version 3)
Technician using the hands-free
Low battery: 9 hours remaining
Dose and alarm
capability of the DMC 2000 S
with LDM 2000 reader.
Health Physics Division
Mirion Technologies (MGPI) Inc
5000 Highlands Parkway Suite 150 Smyrna Georgia 30082 USA T +1.770.432.2744 F +1.770.432.9179
Since norms, specifi cations and designs are subject to occasional change, please ask for confi rmation of the information given in this publication.
Mirion Technologies (MGPI) SA
BP 1 F-13113 Lamanon France
T +33 (0) 4 90 59 59 59 F +33 (0) 4 90 59 55 18
Mirion Technologies (RADOS) Oy
P.O. Box 506 FIN-20101 Turku Finland
T +358 2 468 4600 F +358 2 468 4601
Mirion Technolgies (RADOS) GmbH
Ruhrstrasse 49 DE-22761 Hamburg Germany
T +49 (0) 40 851 93-0 F +49 (0)40 851 93 256
www.mirion.com
144269EN-C