Mirion Technologies DGK 250 User Manual

Featuring:
radiation monitoring systems
A Mirion Technologies Division
DGK 250
Neutron Flux Instrumentation
DGK 250
The DGK 250 digital power range channel forms part
of the proTK™ product line. It has been designed for
neutron  ux monitoring in the power range in combi-
nation with neutron ionization chambers. Hardware
and software of the DGK 250 are designed and
quali ed for applications at the level of the reactor
protection system.
APPLICATIONS
• Operational process monitoring
Safety related signal processing for neutron  ux
monitoring in the power range of pressurized water
reactors and research reactors
RELATED PRODUCTS
• KNK/KNU 50: neutron ionization chambers
• Digital signal processing channels: e.g. for start-up
range or wide range monitoring
FEATURES
Two signal paths for two ionization chambers
Calibration to neutron  ux signal (nv, P/Pn)
Calculation of mean value and deviation
Generation of analog and binary signals for the reactor
protection system
Short response time < 10 ms
Remote test signal generators
RS232/485 data interface
Since norms, speci cations and designs are subject to occasional change, please ask for con rmation of the information given in this publication.
Mirion Technologies (MGPI) SA
Route d’Eyguières FR-13113 Lamanon France
T +33 (0) 4 90 59 59 59 F +33 (0) 4 90 59 55 18
Mirion Technologies (MGPI) Inc
5000 Highlands Parkway Suite 150 Smyrna, GA 30082 USA T +1 770 432 2744 F +1 770 432 9179
Mirion Technologies (MGPI H&B) GmbH
Landsberger Strasse 328a DE-80687 Munich Germany
T +49 (0) 89515 13-0 F +49 (0) 89515 13 169
Mirion Commercial (Beijing) Co., Ltd.
Shanghai Jiangchang Commercial Branch
Room 801, 78 Jiangchang SanLu Zhabei District, Shanghai 200436 PR of China T +86 21 6180 6920 F +86 21 6180 6924
DGK 250
Neutron Flux Instrumentation
www.mirion.com
144967EN-C
DETECTORS AND INPUT SIGNALS
Boron coated ionization chambers (compensated or
non-compensated) e.g. KNU 50 or KNK 50
No external preampli ers
Cable to the DGK 250: coaxial cable, no limitation of
length
Detector supply 0 ... 1 kV located in the central
electronic unit
Selectable ranges of input signals 0 ... 10/20/50 μA
DIGITAL SIGNAL PROCESSING
80C31/32 multi-processor system
Program memory: EPROM
Parameter memory: CMOS-RAM with integrated
Li-battery
Data interface: RS232 and/or RS485
Internal LC-display: 2 x 16 characters
OUTPUT SIGNALS
Neutron  ux at top and bottom position, individually
calibrated
Average neutron  ux, calibrated to reactor power,
e.g. 0 ... 125 %Pn
Neutron  ux deviation between top and bottom
Analog outputs: 0/4 ... 20mA/600 Ω, insulated
Binary outputs: insulated relais change overs,
60V/0.5A or 125V/1A
OTHER CHARACTERISTICS
DC power supply: 18 ... 33 VDC, approx. 1.6A at 24 V
Optional: AC power supply: 230 VAC or 115 VAC
+10%/-15%, approx. 40 VA
Operating temperature: 0 ... 70°C (32 ... 158°F)
for the main electronics
Mechanical vibrations: < 5 g, 5 ... 100 Hz
19” modular system according to IEC 60297
Rack size (W×H×D): 483 mm × 133 mm × 280 mm
(19 in x 5.2 in x 11 in)
Plug-in boards: 100 mm × 160 mm (3.9 in x 6.3 in)