Mircom MUS-5000H, MUS-5000SV, MUS-5024, MUS-5120, MUS-5120H Installation, Programming, And Troubleshooting Manual

...
®
ADC Series
Autodialer Telephone Access Systems
Scrolling & Non-Scrolling Directory
INSTALLATION, PROGRAMMING, and TROUBLESHOOTING MANUAL
LNOTICE
All information, documentation, and specifications contained in this manual are subject to change without prior notice by the manufacturer.
©1998 by Mircom Technologies Limited Printed in CANADA, June 30, 1998 LT-487 Rev.5
TABLE of CONTENTS
IMPORTANT NOTICE . . . . . . . . . . . . . . . . . . 01
SYSTEM FEATURES . . . . . . . . . . . . . . . . . . 02
INTRODUCTION . . . . . . . . . . . . . . . . . . . 03
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . 03
OPERATION . . . . . . . . . . . . . . . . . . . . 03
SYSTEM BLOCK DIAGRAM: PRE-INSTALLATION PLANNING:
ENCLOSURES and ACCESSORIES INSTALLATION INSTRUCTIONS:
SYSTEM WIRING INSTRUCTIONS:
POWERING THE SYSTEM . . . . . . . . . . . . . . . . . 17
ELEVATOR-RECALL(RESTRICTION) FEATURE . . . . . . . . . . . . . 18
PROGRAMMING INSTRUCTIONS FOR ADC Series CONTROLLERS: Scrolling Non-scrolling
Master Code Reset Pins and Fuses Replacement . . . . . . . . . . . . . 45
Lamp replacement (Universal panels only) . . . . . . . . . . . . . . 16
REMOTE PROGRAMMING THE ADC NON-SCROLLING DIRECTORY USING DTMF . . . .. 46
SYSTEM ADJUSTMENTS:
Resident Operating Instructions . . . . . . . . . . . . . . . 50
Troubleshooting . . . . . . . . . . . . . . . . . . . 51
APPENDICES:
Single or Multiple Entrances Application . . . . . . . . . . . . 04
Entry Panel Types . . . . . . . . . . . . . . . . 05
Controllers . . . . . . . . . . . . . . . . . 06
Optional Programming Software Kit: Model RS-485IMK . . . . . . . 06
System & Door Release Power Requirements . . . . . . . . . . 07
Site Selection . . . . . . . . . . . . . . . . . 07
Telephone Line . . . . . . . . . . . . . . . . 07
Wiring Requirements . . . . . . . . . . . . . . . 07
Post Office Lock . . . . . . . . . . . . . . . . 07
Mounting the UNIVERSAL type panels . . . . . . . . . . . . 08
Semi-Flush Trim Ring Installation . . . . . . . . . . . . . 08
Magnetic letter Kit (MLK-040 and MLK-070) . . . . . . . . . . . 10,13
Thermostat Heater Kit Model TH-101 . . . . . . . . . . . . 11
Mounting the CONTINENTAL Type Panels . . . . . . . . . . . 12,13
Wiring the Door Strike or Electromagnetic Door Lock . . . . . . . . . 14
Wiring the Lock-Back Switch . . . . . . . . . . . . . . 15
Wiring the Door Override (Postal Lock & Fire Alarm) . . . . . . . . . 15
Wiring the Auxiliary Relay and Main Entrance Active Relay Contacts . . . . . 16
Wiring the System and Lamps Supplies . . . . . . . . . . . 16
Wiring the Speaker, Mic., and Keypad/Display Assembly . . . . . . . 17
Multiple Entrances and Telephone Line wiring . . . . . . . . . . 17
Wiring to Earth Ground . . . . . . . . . . . . . . . 17
Entering Programming Mode . . . . . . . . . . 21 . . 35
Direct Access Programming Codes Table . . . . . . . 22 . . 36
"No Manual" Programming Using *888 . . . . . . . . . 23 . . 36
Residents’ Dial Code and Telephone Number Entry . . . . . . 23 . . 37
Setting the Tel. # Digit Length . . . . . . . .. 23 . . 37
Change the Prefix Code (for 11-digit Tel. only) . . . . . . 24 . . 37
Entering Residents’ Codes and Tel. # . . . . . . . . 25 . . 38
Entering up to 11-digits Residents’ Tel. #: Special feature . . . . 25 . . 39
Review and Delete Resident Codes . . . . . . . . . . . . 39
Enter, Review, and Edit or Delete Residents’/Tenants’ Names on the List . . . . . 26
Enter Keyless Entry Codes . . . . . . . . . . . 27 . . 39
Review and Delete Keyless Entry Codes . . . . . . . . 28 . . 40
Reprogram Master Code . . . . . . . . . .. 28 . . 40
Select “Door Open Code” for Main and Auxiliary Doors (DTMF only) . . . 29 . . 41
Select Pulse (Rotary) or Tone (DTMF) Dialling . . . . . .. 30 . . 42
Set Door Timer . . . . . . . . . . . . . 31 . . 42
Set On-Line Timer . . . . . . . . . . . . . 31 . . 43
Multiple/Single Entrance Select . . . . . . . . . . 32 . . 43
11 Digit Telephone Number and Code Entry (for long distance call) . . . 32 . . 44
Quit Feature . . . . . . . . . . . . . . 33 . . 44
To Set On-Line Timer to Minutes . . . . . . . . . . 33 . . 45
Sort Residents’ Names . . . . . . . . . . . . . . . 34
Microphone & Speaker Volume, Pulse, and Display Contrast Adjustment . . . . . 48,49
Appendix "A" - Accessory Specifications . . . . . . . . . .. 52
Appendix "B" - Resident Directory Work Sheet . . . . . . . . . . 53
Appendix "C" - Character Set Table for Scrolling Directory . . . . . . . . 54
Warranty . . . . . . . . . . . . . . . . . . . . . 55
IMPORTANT NOTICE
Notice for all ADC SeriesTelephone Entry Systems Sold in Canada
The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to the user's satisfaction.
Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunication company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent degradations of service in some situations.
Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alteration made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment.
Users should ensure for their own protection that the Earth Ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas.
CAUTION: Users should not attempt to make such connections themselves, but should contact the appropriate
electric inspection authority, or electrician, as appropriate.
NOTICE: The LOAD NUMBER (LN) assigned to each terminal device denotes the percentage of the total load
to be connected to a telephone loop which is used by the device, to prevent overloading. The
termination on a loop may consist of any combination of devices subject only to the requirement that
the sum of the load numbers of all devices does not exceed 100.
Industry Canada (formerly D.O.C.) Registration Number: 1156 6662 A
Load Number: 4.4
Notice for all ADC Series Telephone Entry Systems Sold in U.S.A.
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
WARNING : Changes or Modifications not expressly approved by MIRCOM TECHNOLOGIES LTD. could void
the users authority to operate the equipment.
F.C.C. Registration Number: 1M8CAN-22412-OT-E
DC REN: 0.5
AC REN: 0.3B
Notice for all ADC series Telephone Entry System Sold Internationally:
Conformity to the local Tel. Co. standards must be reviewed before installation of ADC Series Telephone Access Systems.
MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 1
SYSTEM FEATURESSYSTEM FEATURES
SCROLLING DIRECTORY FEATURES: NON-SCROLLING DIRECTORY FEATURES:
T SCROLLING DIRECTORY T Up to 1000 programmable Telephone Number; up to 11 digits T Programmable using the lobby panel’s keypad with up to 10 Area Code prefixes.
T 15 Characters Resident/Tenant Name length. Main Door activation codes from 0000 to 4999 T Up to 1000 programmable Telephone Numbers; up to 11 digits Auxiliary Door activation codes from 5000 to 9999
T Up to 1000 4-digits programmable Keyless Entry Codes. extended temperature LCD display.
T 4 lines by 20 characters VFD (Vacuum Fluorescent Display)
COMMON FEATURES FOR BOTH SCROLLING AND NON-SCROLLING TEL. ACCESS SYSTEMS:
T Programmable Pulse(Rotary) or Tone(DTMF) dialling. T User selectable door activation number.
Auxiliary Door relay: 0 to 9 (DTMF only)
T Programmable Master Code for security and programming access. T One 11-digit telephone number for long distance call. T Variable Dial Code length: 1,2,3, or 4 digits format. T Single or Multiple Entrances capability. T Door Override connection for fire alarm; doors will pulse open during emergency. T Built-in Post Office Lock micro switch. T Connection for "Lock Back" door contact to provide door timer cutoff to prevent "tailgating". T Entrance Active Relay Contacts for use of camera activation. T Programmable "Door Open" timer (99 seconds max.) T Programmable "On Line or Conversation Time" timer (99 minutes max.). T Nonvolatile memory (EEPROM), retains programmed information during power failure. T Watch Dog Timer circuit to automatically reset the unit to eliminate system latch-up. T Voice Mail Access capability -the required digits can be entered through the entry panel’s keypad.
®
or IBM PC T Up to 1000 4-digits programmable Keyless Entry Codes.
with up to 10 Area Code prefixes. TSUPERTWIST 2 lines by 16 characters backlit Main Door activation codes from 0000 to 4999
Auxiliary Door activation codes from 5000 to 9999
Main Door relay: 0 to 9 (DTMF) or 7,8,9,0 (Pulse)
MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 2
INTRODUCTION
MIRCOM'S ADC Series Controllers provides a hands-free communication (handset optional) and security controls of devices such as electric door locks, camera, and garage door (auxiliary) in a multi-unit dwelling establishments. The system required a dedicated telephone line to operate. It can be configured for Multiple entrances with independent doors and camera activation function. Its enhanced unique capability to access a voice mail telephone system enables the user to use the entry panel keypad to enter the required digit(s) to reach the individual extension number or to leave important messages. The system uses a nonvolatile memory (EEPROM) that retains programmed information even in the event of power failure. Installation is quick and simple featuring a low voltage operation and complete system programmability using the entry panel’s keypad or IBM PC .
®
Trademark of International Business Machines
SPECIFICATIONS
The operating temperature range is 50EC (122EF) to -20EC(-4EF). For installation where the ambient temperature falls below 0EC (32EF), it is necessary that a TH-101 Thermostat Heater be installed within the enclosure.
The Power Supply voltage range should be 105 to 128 VAC. Use only Loop Start telephones (not ground start), check with your local telephone company.
OPERATIONOPERATION
STANDARD OPERATION FOR SCROLLING DIRECTORY UNITS:
Visitor calling the Resident:
At the entry point (lobby), the visitors locates the Resident's Dial Code and Name by scrolling through the directory list displayed on the screen by using the * or # keys. Pressing the * or # key momentarily will scroll the list "up or down" one name at a time. Holding the * or # key will scroll the list "up or down" continuously and stop scrolling when the key is released. A known Dial Code can be entered directly on keypad without scrolling.When a call is placed, a confirmation ring should be heard on the speaker. When a call is answered, the visitor should be online with the Resident. While online, the Resident may open the appropriate door by dialling the designated number (as programmed) or simply by hanging-up the phone to refuse entry.
STANDARD OPERATION FOR NON-SCROLLING DIRECTORY UNITS: Visitor calling the Resident:
At the entry point (lobby), the visitors locate the Resident’s Dial Code on the directory and enter the appropriate code number on keypad. When a call is placed, a confirmation ring should be heard on the speaker. When a call is answered, the visitor should be online with the Resident. While online, the Resident may open the appropriate door by dialling the designated number (as programmed) or simply by hanging-up the phone to refuse entry.
Important Notice: Residents’ telephone (s) must be capable of generating a “Touch Tone” or DTMF (dual tone multi frequency) or rotary “Pulse” signal for the door release circuit to activate. Below are the valid numbers to open doors.
Main Door Auxiliary Door
Select one from 0 to 9 (DTMF) or 7,8,9,0 (Pulse) Select one from 0 to 9 (DTMF only)
Default is “9" Default is “6"
MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 3
SYSTEM BLOCK DIAGRAMS
SINGLE ENTRANCE APPLICATION:
9508 Elevator Recall Relays
3
3 PS-3B FOR ELEVATOR RECALL RELAY CABINET
MULTIPLE ENTRANCES APPLICATION:
Optional 9508 Elevator Recall
See Note A
PS-3B, FOR ELEVATOR RECALL RELAYS
NOTE A: 4 WIRES FOR RELAY CONTROL (22 AWG, 1 JACKET, SHIELDED)
PS-3B, FOR ELEVATOR RECALL RELAYS
4
See Note A
Optional 9508 Elevator Recall
4
MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 4
PRE-INSTALLATION PLANNING
Before the actual installation begins, the system requires various items to be prearranged and are described below:
1. ENTRY OR LOBBY PANEL TYPES
The UNIVERSAL series entry/lobby panels are hooded surface mount enclosures with built-in lighting for outdoor or indoor applications. Optional flush trim rings are available for semi-flush installations. There are eight (8) models available and are listed below:
Universal Panels for Scrolling Directory:
Model MUS-5000SV ± Stainless Steel finish entry panel comes with keypad, 4x20 VFD
display, microphone, speaker, and micro switch for postal lock. No controller.
Model MUS-5000SHV ± Stainless Steel finish entry panel comes with keypad, 4x20 VFD
display, armoured handset, and micro switch for postal lock. No controller.
Universal Panels for Non-Scrolling Directory:
Model MUS-5000 ± Stainless Steel finish entry panel comes with keypad, 2x16 LCD
display, microphone, speaker, and micro switch for postal lock. No directory and controller.
Model MUS-5000H ± Stainless Steel finish entry panel comes with keypad, 2x16 LCD
display, handset, and micro switch for postal lock. No directory and controller.
Model MUS-5024 ± Stainless Steel finish entry panel comes with keypad, 2x16 LCD
display, microphone, speaker, micro switch for postal lock, and paper directory for 24 names. No controller.
Model MUS-5120 ± Stainless Steel finish entry panel comes with keypad, 2x16 LCD
display, microphone, speaker, micro switch for postal lock, and paper directory for 120 names. No controller.
Model MUS-5120H ± Stainless Steel finish entry panel comes with keypad, 2x16 LCD
display, handset, micro switch for postal lock and paper directory for 120 names. No controller.
Model MUS-5120V ± Stainless Steel finish Vertical (slim) entry panel comes with keypad,
2x16 LCD display, microphone, speaker, micro switch for postal lock, and paper directory for 120 names. No controller.
Accessories:
Model MUFT-5000P ± Flush trim ring for MUS-5000/H/S/SH and MUS-5024 panels. Painted
black (textured).
Model MUFT-5120P ± Flush trim ring for MUS-5120/H, and MPD-5240 panels. Painted
black (textured).
Model MUFT-5120VP ± Flush trim ring for MUS-5120V panel. Painted black (textured).
Model MPD-5120 ± Stainless Steel add-on paper directory panel, 120 names capacity.
Model MPD-5240 ± Stainless Steel add-on paper directory panel, 240 names capacity. Model MLK-040 ± Magnetic strips directory kit, 40 names capacity. It comes with plastic
letters, magnetic strips, brackets, and hexnuts.
Model TH-101 ± Thermostat heater. Note: Painted Silver, Gold & Copper Vein lobby panels are available by custom order.
MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 5
The CONTINENTAL series entry/lobby panels are designed for indoor applications only. These elegant lobby panels can be mounted either flush or surfaced by selecting the appropriate backbox. There are six (6) models available and are listed below:
Continental Panels for Scrolling Directory:
Model MCS-6001SV ± Stainless Steel finish entry panel comes with keypad, 4x20 VFD
display, microphone, speaker, and micro switch for postal lock. No controller.
Model MCS-6001SHV ± Stainless Steel finish entry panel comes with keypad, 4x20 VFD
display, armoured handset, and micro switch for postal lock. No controller.
Continental Panels for Non-Scrolling Directory:
Model MCS-6000 ± Stainless Steel finish entry panel comes with keypad, 2x16 LCD
display, microphone, speaker, and micro switch for postal lock. No directory and controller.
Model MCS-6000H ± Stainless Steel finish entry panel comes with keypad, 2x16 LCD
display, handset, and micro switch for postal lock. No directory and controller.
Model MCS-6240 ± Stainless Steel finish entry panel comes with keypad, 2x16 LCD display,
microphone, speaker, micro switch for postal lock, and paper
directory for 240 names. No controller.
Model MCS-6240H ± Stainless Steel finish entry panel comes with keypad, 2x16 LCD display,
handset, micro switch for postal lock and paper directory for 240
names. No controller.
Accessories:
Model MPD-6240 ± Add-on paper directory panel, 240 names capacity.
Model MPD-6480 ± Add-on paper directory panel, 480 names capacity. Model BBF-6001 ± Flush backbox for MCS-6001S/SH. Satin coat finish. Model BBS-6003 ± Surface backbox for MCS-6001S/SH. Painted black (textured). Model BBF-6101 ± Flush backbox for MCS-6000, MCS-6000H, and MPD-6120 panels. Model BBF-6102 ± Flush backbox for MCS-6240, MCS-6240H, and MPD-6480 panels. Model BBS-6301 ± Surface backbox for MCS-6000, MCS-6000H, and MPD-6240. Model BBS-6302 ± Surface backbox for MCS-6240, MCS-6240H, and MPD-6480
panels.
Model MLK-070 ± Magnetic strip directory kit, 70 names capacity. It comes with plastic
letters, magnetic strips, brackets, and hexnuts.
Note: Painted Silver, Gold & Copper Vein lobby panels are available by custom order.
2. CONTROLLERS
SCROLLING DIRECTORY CONTROLLERS: For both LCD and VFD Display Model ADC-0040SDA ± Autodialer Telephone Access Controller, 40 Residents capacity. Model ADC-0120SDA ± Autodialer Telephone Access Controller, 120 Residents capacity. Model ADC-0360SDA ± Autodialer Telephone Access Controller, 360 Residents capacity. Model ADC-0800SDA ± Autodialer Telephone Access Controller, 800 Residents capacity.
Optional Programming Software Kit:
Model RS-485IMK consists of MirSoft TAS programming software, RS-485 interface module, and cable is an optional programming kit to enable the user to upload or download Residents’ names, dial codes, keyless entry codes, and relay line numbers using a personal computer. This software can be used on IBM PC/XT/286/386/486/Pentium Compatible PC under MS-DOS version 5 or higher, Windows 95 or higher, OS/2 with Colour or Monochrome Text Screen (MDA, CGA, EGA, VGA, SVGA) capability and one serial port. To order this kit, please consult our factory for further information.
MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 6
®
® ® ®
NON-SCROLLING DIRECTORY CONTROLLERS: Model ADC-0040A ± Autodialer Telephone Access Controller, 40 Residents capacity. Model ADC-0120A ± Autodialer Telephone Access Controller, 120 Residents capacity. Model ADC-0360A ± Autodialer Telephone Access Controller, 360 Residents capacity. Model ADC-0960A ± Autodialer Telephone Access Controller, 960 Residents capacity.
Note: Please see page 4 for System Block Diagram for more information.
3. SYSTEM & DOOR RELEASE POWER REQUIREMENTS
A single Mircom's PS-3B (Tri-Volt) power transformer is required to power the unit and lamps. A second power transformer is required to operate the door release. Please note that the transformer and the door release must be compatible. When using Mircom's M-10 door strike, a compatible PS-3B power transformer with 8VAC tapped is used to power the door strike. If using an equivalent door release, the maximum strike load that may be switched through the control unit is 28 VAC or DC, 3 Amp. maximum.
Below are the available power supplies and door strikes:
Model PS-2 ± 16 VAC / 20 VA, CSA approved Class 2 Power Transformer. Model PS-4 ± 16 VAC / 40 VA, CSA approved Class 2 Power Transformer. Model PS-3B ± 8 VAC /13 VA, 16 VAC /17 VA, 24 VAC /20 VA, CSA approved
Class 2 Power Transformer.
Model SPS-600W ± 600 Watts Standby Battery Supply. Model M-10 ± DC (silent) or AC (buzzing) Door Strike. Use PS-3B transformer. Model M-10HD ± AC (buzzing) Heavy Duty Door Strike. Use PS-3B transformer. Model M-20 ± DC (silent) or AC (buzzing) Heavy Duty Door Strike. Use PS-3B transformer.
Important note: The door strike must have its own separate power transformer. Do not tap or use the
system power transformer.
Notes: Please see appendix "A", page 43 for specifications.
Please see page 4 for System Block Diagram for more information.
4. SITE SELECTION
Install the Entry Panel as near as possible to the controlled entry point. Do not install the system to a location where the LCD display is exposed to direct sunlight since it will degrade the visibility.
5. TELEPHONE LINE
A Pulse (rotary) or Touch-Tone (DTMF) dedicated telephone line is required for single or multiple entrances configuration. If possible, have the jack installed inside the control unit enclosure. Provide the following information to phone company when ordering a telephone line:
Industry Canada (formerly D.O.C.) Registration Number: 1156 6662 A F.C.C. Registration Number: 1M8CAN-22412-OT-E
6. WIRING REQUIREMENTS
Count the number of wires and identify the proper gauges that are required for your system configuration. For typical Single or Multiple entrances applications, please refer to page 4 for System Block Diagram. For custom applications, we recommend to consult our Engineering Field Support Personnel for evaluation.
7. POST OFFICE LOCK
The system has a built-in micro switch and mounting hardware for postal lock installation. If a postal service is required, contact the Post Office to obtain the lock.
MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 7
ENCLOSURES AND ACCESSORIES INSTALLATION INSTRUCTIONS
MOUNTING THE UNIVERSAL TYPE LOBBY/ENTRY PANEL
Mount the panel as shown in FIG.1, FIG.2, and FIG. 2A using the supplied screws.
MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 8
FIG. 2: PANEL INSTALLATION
`A'
4 1/2"
`B' 15/16"
9 11/16"
4 5/16"
2"
7/8" & 1 1/8"
KNOCKOUTS (6X)
1 7/16"
FRONT VIEW
2"
1 7/16"
9 11/16"
12 3/4"
4 3/16"
1 9/16"
2 1/2" 5/16"
WALL
(SURFACE)
FLUSH TRIM RING
2 1/2"
SIDE VIEWSIDE VIEW
(SEMI-FLUSH)
1 3/4"
WALL
BOTTOM VIEW
MODEL NO.
MUS-5000/H/S/SH, MUS-5024,MPD-5120
MUS-5120, MUS-5120H, MPD-5240
DIM. `A'
11"
20 3/4"
3/4"
DIM. `B'
9 3/16"
18 15/16"
SEMI-FLUSH TRIM RING IF REQUIRED
MODEL MUFT-5000P MODEL MUFT-5120P
MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 9
FIG.2A: MUS-5120V (Slim Vertical) PANEL INSTALLATION
MOUNTING THE MAGNETIC LETTER KIT MODEL MLK-040 (OPTIONAL)
Mount the Magnetic Letter Kit according to the Installation Instruction (LT-460) that comes with the Kit. Extra characters and magnetic strips can be ordered separately. Please contact the factory or our nearest dealer.
MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 10
MOUNTING THE THERMOSTAT HEATER KIT MODEL TH-101 (OPTIONAL)
Mount the Heater Kit according to the Fig 2B. Install the TH-101 Heater into bottom left hand corner of the universal enclosure using the two spacers and two hex nuts provided. Use a pair of #18 AWG wires to connect from the TH­101 unit to 24VAC tap on the PS-3B transformer. The transformer must be installed outside the enclosure.
Fig. 2B HEATER INSTALLATION
MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 11
MOUNTING THE CONTINENTAL TYPE LOBBY/ENTRY PANEL Mount the panels as shown in FIG.3 (for scrolling) or FIG.3A (for non-scrolling) using the supplied screws.
FIG. 3: SCROLLING DIRECTORY PANELS
5 15/16"
BOTTOM VIEW
2"
(SURFACE)
BOTTOM VIEW
(FLUSH)
DOOR FRAME FOR
MCS-6001S , MCS-6001SH
1"
BACKBOX (SURFACE)
BACKBOX
1 5/16"
1"
BACKBOX
SIDE VIEW
(SURFACE)
BBS-6003
BACKBOX (FLUSH)
BBF-6001
WIDTH
13 11/16"
WIDTH
11 1/4"
SIDE VIEW
HEIGHT
15 9/16"
HEIGHT
13 13/16"
(FLUSH)
DEPTH
2 3/16"
DEPTH
2 3/16"
MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 12
FIG. 3A: NON-SCROLLING DIRECTORY PANELS
`A' `B'
(DOOR NOT SHOWN)
7/8" & 1 1/8"
KNOCKOUTS (4X)
FRONT VIEW
5 15/16"
2"
4 1/8"
DOOR FRAME
2 3/8"
1 7/16"
15 5/8"
20 1/2"
2 1/4" 2 3/16"
5/16"
20 5/16"
WALL WALL
SIDE VIEW
(SURFACE)
18 1/2"
1"
SIDE VIEW
(FLUSH)
BOTTOM VIEW
(SURFACE)
BOTTOM VIEW
(FLUSH)
BACKBOX
1 5/16"
1"
BACKBOX
1"
BACKBOX (SURFACE)
BBS-6301 BBS-6302
BACKBOX (FLUSH)
BBF-6101 BBF-6102
PANEL MODEL NO.
MCS-6000, MCS-6000H, MPD-6240 MCS-6240, MCS-6240H, MPD-6480 23 5/8"
WIDTH
13 11/16"
23 7/16"
WIDTH
11 1/4"
21"
HEIGHT
20 5/16" 20 5/16"
HEIGHT
18 1/2" 18 1/2"
DIM. `A'
13 7/8"
DEPTH
2 3/16" 2 3/16"
DEPTH
2 3/16" 2 3/16"
DIM. `B'
9 3/16"
18 15/16"
MOUNTING THE MAGNETIC LETTER KIT MLK-070 (OPTIONAL)
Mount the Magnetic Letter Kit according to the Installation Instruction (LT-460) that comes with the Kit. This kit is used only for Continental type lobby/entry panel.
MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 13
SYSTEM WIRING INSTRUCTIONS
WIRING THE DOOR STRIKE
Wire the Door Strike as shown in FIG.4.
WIRING THE ELECTROMAGNETIC DOOR LOCK
Wire as shown in FIG. 5.
MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 14
WIRING THE LOCK-BACK SWITCH
Wire the Lock-Back Switch as shown in FIG. 6 to enable automatic door-open timer cut-off.
WIRING THE DOOR OVERRIDE (Postal Lock & Fire Alarm)
Wire as shown on FIG.7.
MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 15
WIRING THE AUXILIARY RELAY and MAIN ENTRANCE ACTIVE RELAY CONTACTS
Wire as shown in FIG.8.
WIRING THE SYSTEM and LAMP SUPPLIES
Wire as shown in FIG. 9.
MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 16
Loading...
+ 42 hidden pages