Miranda RCP-100 Installation Manual

P
RCP-100
Guide to Installation and Operation
M191-9900-110
Copyright 2009 Miranda Technologies Inc.
Specifications may be subject to change
Printed in Canada
June 2009
Miranda Technologies Inc.
3499 Douglas-B.-Floreani St-Laurent, Québec, Canada H4S 1Y6
Tel. 514-333-1772 Fax. 514-333-9828 www.miranda.com
Remote Control Panel
-100
RC
GUIDE TO INSTALLATION AND OPERATION
Safety Compliance Information
Safety Compliance
This equipment complies with:
- CAN/CSA C22.2 No. 60950-1-07 Safety of Information Technology Equipment, Including Electrical Business Equipment
- UL60950-1 (2nd Edition) Safety of Information Technology Equipment, Including Electrical Business Equipment.
- IEC60950 (2nd Edition) / Safety of Information Technology Equipment, Including Electrical Business Equipment.
CAUTION
These servicing instructions are for use by qualified service personnel only. T o reduce the risk of electric shock, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so. Refer all servicing to qualified service personnel. Servicing should be done in a sta tic-free environment.
Electromagnetic Compatibility
- This equipment has been tested for verification of compliance with FCC Part 15, Subpart B, Class A requirements for Digital Devices.
- This equipment complies with the requirements of: EN 55022 Class A, Radiated Emissions. EN 55022 Class A, Conducted Emissions EN 61000-4-2, -3, -6, -11 Electromagnetic Immunity EN 61000-3-2 & -3-3, Electromagnetic Disturbance in Supply Systems
How to contact us:
For technical assistance, please contact the Miranda Technical support centre nearest you:
Americas
Telephone:
+1-800-224-7882
e-mail:
techsupp@miranda.com
China
Visit our web site at www.miranda.com
Asia
Telephone:
+852-2539-6987
e-mail:
asiatech@miranda.com
Telephone:
+86-10-5873-1814
e-mail:
asiatech@miranda.com
Europe, Middle East, Africa, UK
Telephone:
+44 (0) 1491 820222
e-mail:
eurotech@miranda.com
France (only)
Telephone:
+33 (0) 1 55 86 87 88
e-mail:
eurotech@miranda.com
RCP-100
GUIDE TO INSTALLATION AND OPERATION
Table of Contents
1 RCP-100 Remote Control Panel ................................................................................................1
1.1 Introduction .........................................................................................................................................1
1.2 Features..............................................................................................................................................1
2 Overview .....................................................................................................................................2
2.1 Front Panel..........................................................................................................................................2
2.2 Rear Panel.......................................................................................................................................... 2
3 Installation ..................................................................................................................................3
3.1 Unpacking........................................................................................................................................... 3
3.2 Rack Mount Installation....................................................................................................................... 3
3.3 Electrical Installation ...........................................................................................................................3
3.4 Networking Considerations................................................................................................................. 4
3.4.1 Serial Port Connection...........................................................................................................4
3.4.2 Ethernet Connection ..............................................................................................................4
3.4.3 Typical Operating Configurations........................................................................................... 5
4 Operation ....................................................................................................................................8
4.1 Powering Up........................................................................................................................................8
4.2 Using the RCP-100 - Controls and Displays.......................................................................................8
4.2.1 LCD Display........................................................................................................................... 8
4.2.2 Function Keys ........................................................................................................................8
4.2.3 Pushbuttons........................................................................................................................... 8
4.2.4 Rotary Encoders with pushbutton.......................................................................................... 9
4.2.5 Reset Switch.......................................................................................................................... 9
4.3 Device Selection Mode....................................................................................................................... 9
4.3.1 Device Selection Error Messages........................................................................................10
4.3.2 Device Locking.....................................................................................................................12
4.3.3 Panel Configuration..............................................................................................................12
4.4 Device Control Mode.........................................................................................................................14
4.4.1 Parameter Page Keys.......................................................................................................... 15
4.4.2 Parameter Modifications ......................................................................................................16
4.4.3 Device Status....................................................................................................................... 16
4.4.4 Requirement to Restart the RCP-100.................................................................................. 17
4.5 Disabled Cards.................................................................................................................................. 17
5 Upgrading the Operating Software.........................................................................................18
5.1 Upgrading using an external Compact Flash card............................................................................ 18
5.2 Upgrading using Telnet and FTP...................................................................................................... 19
6 Specifications ...........................................................................................................................21
RCP-100
GUIDE TO INSTALLATION AND OPERATION
RCP-100
GUIDE TO INSTALLATION AND OPERATION
1 RCP-100 Remote Control Panel
1.1 Introduction
The RCP-100 is a simple, 1RU remote control panel that controls the Miranda imaging and Densité families of products, and the Aquila upconverter. It has been designed to address the demands placed by on-air operations.
Emphasis has been placed on the ease of adjustment of key operational parameters by non-techni cal operators. In designing the user interface, it has been assumed that adjustments are often made under time pressure. The use of large buttons with integrated LCD displays, a bright backlit multi-line LCD display, rotary encoders and push-button switches gives users instant access to all key operational and configuration parameters of most modules, even in low-light environments.
1.2 Features
- Support for RS-422 protocol
- Five backlit buttons with built-in LCD for dynamic display of available functions
- Four rotary encoders and six push-buttons with built-in LED for complete controls over functions
- Large LCD for display of parameters
- Built-in, universal power supply
RCP-100 | 1
GUIDE TO INSTALLATION AND OPERATION
y
2 Overview
2.1 Front Panel
The RCP-100 front panel consists of the following:
- the function keys: five large pushbuttons with backlit LCD;
- six pushbuttons, five with built-in LED;
- four rotary encoders with pushbutton;
- a large backlit LCD display;
- a Compact Flash (CF) card slot;
- reset switch;
- four mounting holes for rack mount installation.
Mounting holes
Figure 2.1 RCP-100 front panel
2.2 Rear Panel
The rear panel includes an AC outlet, vents, an HD-15 connector for GPI inputs/outputs (future use), one DE-9 connector for RS-232 communication (port A), two DE-9 connectors fo r RS-232 and RS-422 communication (port B) and one RJ-45 connector with LED indicator for ethernet communication.
Function keys
Pushbuttons
Rotary encoders LCD displa
CF card slot
Reset switch
Figure 2.2 RCP-100 rear panel
2 | RCP-100
GUIDE TO INSTALLATION AND OPERATION
3 Installation
3.1 Unpacking
Make sure the following items have been shipped with your RCP-100. If any of the following items are missing, contact your distributor or Miranda Technologies Inc.
- RCP-100 unit
- AC power cord
3.2 Rack Mount Installation
The RCP-100 is intended to be mounted in a standard 19" equipment rack. The unit is secured to the rack using appropriate rack screws and washers (not provided).
For proper ventilation, make sure the rear and side panel air vents are not blocked.
3.3 Electrical Installation
RS-232 (port A)
This connector is reserved for future expansion
RS-232 (port B)
Use this connector with an RS-232/RS-422 converter to connect the unit to imaging Symphonie, Solo, Quartet and Quartet-2 series frames. Refer to figure 3.1 for connector pinout.
Figure 3.1 RS-232 connector Pinout (DE-9 male) RS-422 Serial Connection (port B)
Use this connector to connect the unit to imaging Symphonie, Solo or Quartet and Quartet-2 series frames. Refer to figure 3.2 for connector pinout.
Figure 3.2 RS-422 Connector Pinout (DE-9 female)
RCP-100 | 3
GUIDE TO INSTALLATION AND OPERATION
Ethernet
Use this RJ-45 female connector to connect the RCP-100 to a Local Area Network (LAN) using common 10BASE-T cables. The LED next to the RJ-45 connector will turn on to indicate network activity.
AC IN
The RCP-100 features a universal power supply. Connect the supplied AC power cord to the AC IN connector on the rear panel.
3.4 Networking Considerations
The RCP-100 has two means of accessing devices which it can control:
3.4.1 Serial Port Connection
All imaging frame rear panels (except the Quartet base model) include 2 identical RS-422 ports which may be used interchangeably as the source or as a daisy chain loop-through. These ports e nable communication between a series of imaging frames and the RCP-100. Remember that the last frame in a daisy chain requires a termination. Figure 3.3 gives an example of a daisy chain hook-up. Refer to the imaging frame’s Guide to Installation and Operation for details on daisy chain installation and cable constructi on.
Figure 3.3 Daisy chain installation example RS-422 Serial ID Assignment
In order for an RCP-100 to control the cards in a daisy-chain of frames, the RCP-100 must be able to identify and access each frame individually. The only way to accomplish this is to assign an identification code to each member of the daisy chain. This is similar to assigning different addresses to buildings on a street. Refer to the imaging frame’s Guide to Installation and Operation for details on how to set these ID codes.
3.4.2 Ethernet Connection
The RCP-100 can connect to a LAN through its ethernet port, and control those devices which have been specified in the directory files. At present, RCP-100 supports the Miranda Densité series of frames and cards, when they are equipped with an ethernet controller card (ETH-CPU). It is also possible to order an RCP-100 configured specially to operate Miranda's Aquila serie s of upconverters; such panels will not control other Miranda devices.
From the software point of view, RCP-100 contains three separate modules: (1) Client, (2) Directory Services, and (3) serial/ethernet Communications and Services. All three of these modules are required to be present on the LAN, and each could run separately on a different RCP-100, which would communicate among themselves using the TCP protocol. However, in most situations, there are only two practical configurations for an RCP-100: