Miranda HDA-1861 Installation Manual

DENSITÉ series
HDA-1861
Reclocked HD/SD/ASI DA with EQ
Guide to Installation and Operation
M950-9900-100
15 Mar 2011
Miranda
Technologies Inc.
3499 Douglas-B.-Floreani
St-Laurent, Québec, Canada H4S 2C6
Tel. 514-333-1772
www.miranda.com
© 2011 Miranda Technologies Inc.
Fax. 514-333-9828
GUIDE TO INSTALLATION AND OPERATION
Electromagnetic Compatibility
This equipment has been tested for verification of compliance with FCC Part 15, Subpart B requirements for Class A digital devices.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
This equipment has been tested and found to comply with the requirements of the EMC directiv e 2004/108/CE:
EN 55022 Class A radiated and conducted emissions
EN 50204 Radiated EMF immunity – 900 MHz pulsed
EN 61000-3-3 Limitation of voltage changes, voltage fluctuations and flicker
EN 61000-4-2 Electrostatic discharge immunity
EN 61000-4-3 Radiated electromagnetic field immunity – radio frequencies
EN 61000-4-8 Power frequency magnetic field immunity
EN 61000-4-11 Voltage-dips, short-interruptions and voltage variations immunity
How to contact us:
For technical assistance, please contact the Miranda Technical support centre nearest you:
Americas
Telephone:
+1-800-224-7882
e-mail:
techsupp@miranda.com
China
Visit our web site at www.miranda.com
Asia
Telephone:
+852-2539-6987
e-mail:
asiatech@miranda.com
Telephone:
+86-10-5873-1814
e-mail:
asiatech@miranda.com
Europe, Middle East, Africa, UK
Telephone:
+44 (0) 1491 820222
e-mail:
eurotech@miranda.com
France (only)
Telephone:
+33 (0) 1 55 86 87 88
e-mail:
eurotech@miranda.com
HDA-1861
GUIDE TO INSTALLATION AND OPERATION
Table of Contents
1 HDA-1861 Reclocked HD/SD/ASI DA with EQ ......................................................................... 5
1.1 Introduction ......................................................................................................................................... 5
1.2 Features .............................................................................................................................................. 5
1.3 Block Diagram ..................................................................................................................................... 5
1.4 Front Card-edge Interface ................................................................................................................... 6
2 Installation .................................................................................................................................. 7
2.1 Installation of Rear Connector Panels ................................................................................................ 7
2.2 Card Installation .................................................................................................................................. 8
2.3 Installing Densité-2 Cards and Rear Modules in a Densité-3 Frame ................................................. 8
2.4 Signal Connections on Rear Connector Panels ............................................................................... 10
3 Operation .................................................................................................................................. 11
3.1 Card-Edge Status LED ..................................................................................................................... 11
3.2 Local control using the Densité frame control panel ......................................................................... 11
3.2.1 Overview .............................................................................................................................. 11
3.2.2 Menu for local control ........................................................................................................... 12
4 Specifications ........................................................................................................................... 14
HDA-1861
GUIDE TO INSTALLATION AND OPERATION
HDA-1861
GUIDE TO INSTALLATION AND OPERATION
1 HDA-1861 Reclocked HD/SD/ASI DA with EQ
1.1 Introduction
The HDA-1861 is a reclocked HD/SD distribution amplifier with up to 9 outputs and automatic equalization for up to 140 meters of cable (Belden 1694A). Reclocking of the video signals provides an additional level of signal integrity in long cable length applications. The HDA-1861 DA supports both HD-SDI (SMPTE 292M) and SD-SDI (SMPTE 259M­C) and also offers signal presence detection and remote reporting.
1.2 Features
 HD/SD-SDI input  (9) reclocked HD/SD-SDI outputs  HD SDI (1.485, 1.485/1.001 Gbps) is reclocked  SD SDI (270 Mbps) is reclocked  Other SD signals (143/177/360/540) are equalized but not reclocked  140 m automatic cable equalization in HD  300 m automatic cable equalization in SD  Signal presence detection with remote reporting
1.3 Block Diagram
This block diagram shows the functionality of the HDA-1861.
Figure 1.1 Functional block diagram of the HDA-1861