Mirage IAPH301A, OAPH301A, IAPH361A, OAPH361A Owner's Manual

OWNER’S MANUAL
Split Air Conditioner
Thank you for choosing our product. For proper operation, please read and keep this manual carefully. If you have lost the Owner’s Manual, please visit: www.mirageappliances.us
IAPH301A / OAPH301A IAPH361A / OAPH361A
Explanation of Symbols
Indicates a hazardous situation that, if not avoided, will result in death or serious injury.
Indicates a hazardous situation that, if not avoided, could result in death or serious injury.
Indicates a hazardous situation that, if not avoided, may result in minor or moderate injury.
Indicates important but not hazard-related information, used to indicate risk of property damage.
Indicates a hazard that would be assigned a signal word WARNING or CAUTION.
DANGER
WARNING
CAUTION
NOTICE
Content
Operation Notices
Precautions ........................................................................................................
Parts name .......................................................................................................
Screen Operation Guide
Buttons on remote controller .............................................................................
Introduction for icons on display screen ...........................................................
Introduction for buttons on remote controller ....................................................
Function introduction for combination buttons ..................................................
Operation guide .................................................................................................
Replacement of batteries in remote controller ..................................................
Emergency operation ........................................................................................
Maintenance
Clean and maintenance ....................................................................................
Malfunction
Malfunction analysis ..........................................................................................
Installation Notice
Installation dimension diagram ..........................................................................
Safety precautions for installing and relocating the unit ...................................
Tools for installation ...........................................................................................
Selection of installation location ........................................................................
Requirements for electric connection ...............................................................
Installation
Installation of indoor unit .....................................................................................
Installation of outdoor unit ...................................................................................
Vacuum pumping.................................................................................................
Leakage detection ...............................................................................................
Check after installation .......................................................................................
Test and operation
Test operation ....................................................................................................
Attachment
Conguration of connection pipe .......................................................................
Pipe expanding method .....................................................................................
1 6
7 7
8 12 14 14 15
15
18
22 23 24 24 25
26 31 34 34 35
35
36 38
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
If it needs to install, move or maintain the air conditioner, please contact dealer or local service center to conduct
it at rst. Air conditioner must be installed, moved or maintained by appointed unit. Otherwise, it may cause
serious damage or personal injury or death.
1
Operation and Maintenance
• This appliance can be used by children aged from 8 years
and above and persons with reduced physical, sensory ormental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
• Children shall not play with the appliance.
• Cleaning and user maintenance shall not be made by
children without supervision.
• Do not connect air conditioner to multi-purpose socket. Otherwise, it may cause re hazard.
• Do disconnect power supply when cleaning air conditioner.
Otherwise, it may cause electric shock.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualied
persons in order to avoid a hazard.
• Do not wash the air conditioner with water to avoid electric
shock.
• Do not spray water on indoor unit. It may cause electric
shock or malfunction.
• After removing the lter, do not touch ns to avoid injury.
• Do not use re or hair dryer to dry the lter to avoid deformation or re hazard.
• Maintenance must be performed by qualied professionals.
Otherwise, it may cause personal injury or damage.
• Do not repair air conditioner by yourself. It may cause electric shock or damage. Please contact dealer when you need to repair air conditioner.
• Do not extend ngers or objects into air inlet or air outlet. It
may cause personal injury or damage.
Precautions
WARNING
2
Precautions
• Do not block air outlet or air inlet. It may cause malfunction.
• Do not spill water on the remote controller, otherwise the
remote controller may be broken.
• When below phenomenon occurs, please turn o󰀨 air conditioner and disconnect power immediately, and then
contact the dealer or qualied professionals for service.
- Power cord is overheating or damaged.
-There’s abnormal sound during operation.
- Circuit break trips o󰀨 frequently.
- Air conditioner gives o󰀨 burning smell.
- Indoor unit is leaking.
• If the air conditioner operates under abnormal conditions, it may cause malfunction, electric shock or re hazard.
• When turning on or turning o󰀨 the unit by emergency
operation switch, please press this switch with an insulating object other than metal.
• Do not step on top panel of outdoor unit, or put heavy objects. It may cause damage or personal injury.
WARNING
3
Precautions
Attachment
• Installation must be performed by qualied professionals.
Otherwise, it may cause personal injury or damage.
• Must follow the electric safety regulations when installing
the unit.
• According to the local safety regulations, use qualied power supply circuit and circuit break.
• Do install the circuit break. If not, it may cause malfunction.
• An all-pole disconnection switch having a contact
separation of at least 3mm in all poles should be connected
in xed
wiring.
• Including a circuit break with suitable capacity, please note
the following table. Air switch should be included magnet buckle and heating buckle function, it can protect the circuit-short and overload.
• Air Conditioner should be properly grounded. Incorrect
grounding may cause electric shock.
• Don’t use unqualied power cord.
• Make sure the power supply matches with the requirement
of air conditioner. Unstable power supply or incorrect wiring or malfunction. Please install proper power supply cables before using the air conditioner.
• Properly connect the live wire, neutral wire and grounding
wire of power socket.
• Be sure to cut o󰀨 the power supply before proceeding any
work related to electricity and safety.
WARNING
4
Precautions
• Do not put through the power before nishing installation.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualied
persons in order to avoid a hazard.
• The temperature of refrigerant circuit will be high, please
keep the interconnection cable away from the copper tube.
• The appliance shall be installed in accordance with national
wiring regulations.
• Installation must be performed in accordance with the requirement of NEC and CEC by authorized personnel only.
• The air conditioner is a rst class electric appliance. It must
be properly grounding with specialized grounding device by a professional. Please make sure it is always
grounded e󰀨ectively, otherwise it may cause electric shock.
•The yellow-green wire in air conditioner is grounding wire,
which can’t be used for other purposes. The grounding resistance should comply with national electric safety regulations.
• The appliance must be positioned so that the plug is accessible.
• All wires of indoor unit and outdoor unit should be connected by a professional.
• If the length of power connection wire is insu󰀩cient, please
contact the supplier for a new one. Avoid extending the wire by yourself.
WARNING
5
Precautions
• For the air conditioner with plug, the plug should be reachable after nishing installation.
• For the air conditioner without plug, an circuit break must
be installed in the line.
• If you need to relocate the air conditioner to another place, only the qualied person can perform the work. Otherwise, it
may cause personal injury or damage.
• Select a location which is out of reach for children and far
away from animals or plants. If it is unavoidable, please add the fence for safety purpose.
• The indoor unit should be installed close to the wall.
Working temperature range
Indoor side DB/WB(°F) Outdoor side DB/
WB(°F)
Maximum cooling 80/67 115/75
Maximum heating 80 75/65
• The operating temperature range (outdoor temperature) for cooling only unit is -0.4°F (-18°C) ~ 115°F (46.1 °C); for heat pump unit is -4°F (-20°C) ~ 115°F (46.1°C)
WARNING
NOTICE
6
Parts Name
Indoor Unit
Outdoor Unit
Actual product may be di󰀨erent from above graphics, please
refer to actual products.
air inlet
Connection wire
air outlet
air inlet
panel
aux.button
horizontal louver
air outlet
NOTICE
remote control
7
Buttons on remote controller
Introduction for icons on display screen
5
3
6
8
10
12
11
9
7
4
2
1
1
2
3
4
5
6
7
8
9
10
11
12
ON/OFF button
MODE button
FAN button
SWING button
TURBO button
TEMP button
I FEEL button
LIGHT button
CLOCK button
TIMER ON / TIMER OFF button
SLEEP button
Send signal Turbo mode
46°F heating function
Set temperature
Set time TIMER ON /
TIMER OFF Child lock
Up & down swing
Set fan speed
Light
Temp. display type
:Set temp.
:Outdoor ambient temp.
:Indoor ambient temp.
Sleep mode
Clock
Heat mode
Fan mode
Dry mode
Cool mode
Auto mode
Operation mode
I feel
8
Introduction for buttons on remote controller screen
Note:
• This is a general use remote controller, it could be used for the air conditioners with multifunction; For some function, which the model doesn’t
have, if press the corresponding button on the remote controller that the unit will keep the original running status.
• After putting through the power, the air conditioner will give out a sound.
Operation indictor is ON (red indicator). After that, you can operate the air conditioner by using remote controller.
• Under on status, pressing the button on the remote controller, the signal
icon “ ” on the display of remote controller will blink once and the air conditioner will give out a “de” sound, which means the signal has been sent to the air conditioner.
• Under o󰀨 status, set temperature and clock icon will be displayed on the display of remote controller (If timer on, timer o󰀨 and light functions are set,
the corresponding icons will be displayed on the display of remote controller
at the same time); Under on status, the display will show the corresponding
set function icons.
Press this button can turn on or turn o󰀨 the air conditioner. After turning on
the air conditioner, operation indicator on indoor unit’s display is ON (green
indicator. The colour is di󰀨erent for di󰀨erent models), and indoor unit will give
out a sound.
Press this button to select your required operation mode.
• When selecting auto mode, air conditioner will operate automatically
according to ex-factory setting. Set temperature can’t be adjusted and will not be displayed as well. Press “FAN” button can adjust fan speed. Press “SWING” button can adjust fan blowing angle.
• After selecting cool mode, air conditioner will operate under cool mode. Cool indicator on indoor unit is ON. Press “▲” or “▼“ button to adjust set
temperature. Press “FAN” button to adjust fan speed. Press “SWING” button to adjust fan blowing angle.
• When selecting dry mode, the air conditioner operates at low speed under dry mode. Dry indicator on indoor unit is ON. Under dry mode, fan speed
can’tbe adjusted. Press “SWING” button to adjust fan blowing angle.
• When selecting fan mode, the air conditioner will only blow fan, no cooling
and no heating. Press “FAN” button to adjust fan speed. Press “SWING” button to adjust fan blowing angle.
ON/OFF button
1
MODE button
2
9
When selecting heating mode, the air conditioner operates under heat mode.
Heat indicator on indoor unit is ON. Press “▲” or “▼“ button to adjust set
temperature. Press “FAN” button to adjust fan speed. Press “SWING” button to adjust fan blowing angle. (Cooling only unit won’t receive heating mode
signal. If setting heat mode with remote controller, press ON/OFF button
can’t start up the unit).
Note:
For preventing cold air, after starting up heating mode, indoor unit will delay
1~5 minutes to blow air (actual delay time is depend on indoor ambient
temperature).
Set temperature range from remote controller: 61~86°F; Fan speed: auto,
low speed, medium speed, high speed.
Pressing this button can set fan speed circularly as: auto (AUTO), low( ), medium ( ), high( ).
Note:
• Under AUTO speed, air conditioner will select proper fan speed
automatically according to ex-factory setting.
• Fan speed under dry mode is low speed.
Press this button can select up&down swing angle. Fan blow angle can be selected circularly as below:
• When selecting “ “, air conditioner is blowing fan automatically. Horizon­tal louver will automatically swing up & down at maximum angle.
• When selecting “ “ air conditioner is blowing fan at xed position. Horizontal louver will stop at the xed position.
• When selecting “ “ air conditioner is blowing fan at xed angle. Horizontal louver will send air at the xed angle.
• Hold “ “ button above 2s to set your required swing angle. When reach-
ing your required angle, release the button.
Note:
“ “may not be available. When air conditioner receives this signal, the air conditioner will blow fan automatically.
Introduction for buttons on remote controller screen
FAN button
3
SWING button
4
Auto
no display (horizontal louvers stops at current position)
10
Introduction for buttons on remote controller screen
TURBO button
5
Under COOL or HEAT mode, press this button to turn to quick COOL or quick HEAT mode. “ “ icon is displayed on remote controller. Press this button again to exit turbo function and “ “ icon will disappear.
• Press “▲” or “▼ “ button once increase or decrease set temperature 1 ˚C (1°F); Holding “▲” or “▼ “ button, 2s later, set temperature on remote controller will change quickly. On releasing button after setting is nished,
temperature indicator on indoor unit will change accordingly. (Temperature can’t be adjusted under auto mode)
• When setting TIMER ON, TIMER OFF or CLOCK, press “▲” or “▼“ button
to adjust time. (Refer to CLOCK, TIMER ON, TIMER OFF buttons) When
setting TIMER ON, TIMER OFF or CLOCK, press “▲” or “▼ “ button to
adjust time. (Refer to CLOCK, TIMER ON, TIMER OFF buttons)
Under COOL, HEAT or DRY mode, press this button to start up sleep
function. “ “ icon is displayed on remote controller. Press this button again to cancel sleep function and “ “ icon will disappear.
By pressing this button, you can see indoor set temperature, indoor ambient temperature or outdoor ambient temperature on indoor unit’s display. The setting on remote controlleris selected circularly as below:
• When selecting “ “ or no display with remote controller, temperature
indicator on indoor unit displays set temperature.
• When selecting “ “ with remote controller, temperature indicator on
indoor unit displays indoor ambient temperature.
• When selecting “ “ with remote controller, temperature indicator on
indoor unit displays outdoor ambient temperature.
Note:
• Outdoor temperature display is not available for some models. At that time,
indoor unit receives “ “ signal, while it displays indoor set temperature.
▲/▼ button
6
SLEEP button
7
TEMP button
8
no display