Mira Sport Maintance Manual

1
Maintenance Guide
Operation &B
Installation
ELECTRIC SHOWERS
THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER
10.8 kW
2
Contents
Section Page
1 ..... Introduction ................................................................... 3
2 ..... Important Safety Information........................................... 4
3 ..... Pack Contents Checklist .................................................. 6
4 ..... Dimensions ................................................................... 7
5 ..... Wiring Diagram ................................................................. 8
6 ..... Specifications ................................................................... 9
7 ..... Installation Requirements .............................................. 10
8 ..... Installation ................................................................. 14
9 ..... Commissioning............................................................... 17
10 ... Operation......................................................................... 19
11 ... Maintenance .................................................................... 23
12 ... Fault Diagnosis ............................................................... 30
13 ... Spare Parts...................................................................... 32
14 ... Accessories .................................................................... 34
Guarantee, Customer Care Policy, and How to contact us
.............................................................................. Back cover
3
Section
1
Introduction
If you experience any difficulty with the installation or operation of your new shower control, then please refer to the Fault Diagnosis section, before contacting Caradon Plumbing Solutions. Our telephone and fax numbers can be found on the back cover of this guide.
Thank you for purchasing a quality Mira product. To enjoy the full potential of your new product, please take time to read this guide thoroughly, having done so, keep it handy for future reference.
The Mira Sport electric shower has separate controls for power selection and temperature/ flow adjustment. A unique flow regulator stabilises temperature changes caused by water pressure fluctuations. These can result from taps being turned on or off or toilets being flushed.
Mira Sport 10.8 - A 10.8 kW 240 V AC (9.9 kW 230 V AC) heater with a Mira RF1 adjustable spray handset with three different spray actions (start, force and soothe).
Individual lights indicate 'Standby', 'Low Flow' and 'Overheat'. Supplied complete with flexible hose, adjustable clamp bracket assembly, soap dish,
slide bar, supports and hose retaining ring. Available in the following finishes; white/chrome, white and light golden.
4
Section
2
Important Safety Information
1. WARNING!
1.1. Products manufactured by us are safe and without risk provided they are
installed, used and maintained in good working order in accordance with our instructions and recommendations.
1.2. THIS MIRA SPORT MUST BE EARTHED.
1.3. In accordance with the current edition of ‘The Plugs and Sockets etc. (Safety)
Regulations' in force at the time of installation, this Mira Sport is intended to be permanently connected to the fixed electrical wiring of the mains system.
1.4. DO NOT twist the individual cable cores of the live and neutral conductors, as this will prevent them from entering the terminal block.
1.5. Make sure that any pipework that could become frozen is properly insulated.
1.6. DO NOT operate this Mira Sport if it is frozen. Allow the Mira Sport to thaw before using again. DO NOT use if suspected of being frozen.
1.7. If water leaks from the pressure relief valve, maintenance will be required before
the Mira Sport can be safely used.
1.8. DO NOT fit any form of outlet flow control as the outlet acts as a vent for the tank body. Only Mira recommended outlet fittings should be used.
1.9. There are no user serviceable components beneath the cover of the Mira Sport. Only a competent tradesperson should remove the cover.
1.10. If any of the following conditions occur, isolate the electricity and water supplies and refer to “To contact us”, on the back page of this guide.
1.11. Isolate the electrical and water supply before removing the cover.
1.12. Mains connections are exposed when the cover is removed.
1.10.1. If the cover is not correctly fitted and water has entered the Mira Sport
case.
1.10.2. If the case is damaged.
1.10.3. If the Mira Sport begins to make an odd noise, smell or smoke.
1.10.4. If the Mira Sport shows signs of a distinct change in performance,
indicating a need for maintenance.
1.10.5. If the Mira Sport is frozen.
5
1.13. Refer to the wiring diagram before making any electrical connections.
1.14. Ensure all electrical connections are tight, to prevent overheating.
2. Caution!
2.1. Read all of these instructions and retain this guide for later use.
2.2. Pass on this guide in the event of change of ownership of the installation site.
2.3. Follow all warnings, cautions and instructions contained in this guide, and on or
inside the Mira Sport.
2.4. The electrical installation must comply with the “Requirements for Electrical Installations” commonly referred to as the IEE Wiring Regulations, or any particular regulations and practices, specified by the local electricity supply company in force at the time of installation. The installation should be carried out by an electrician or contractor who is registered, or is a member of, an association such as:
2.5. This is a high power unit; it is essential to contact your electricity supply company to ensure that the electricity supply is adequate for the purpose.
2.6. The plumbing installation must comply with the requirements of UK Water Regulations/Bylaws (Scotland), Building Regulations or any particular regulations and practices, specified by the local water company or water undertakers. The installation should be carried out by a plumber or contractor who is registered, or is a member of, an association such as:
2.7. Anyone who may have difficulty understanding or operating the controls of any shower should be attended whilst showering. Particular consideration should be given to the young, the elderly, the infirm, or anyone inexperienced in the correct operation of the controls.
2.8. When this Mira Sport has reached the end of its serviceable life, it should be disposed of in a safe manner, in accordance with current local authority recycling, or waste disposal policy.
2.4.1. National Inspection Council for Electrical Installation and Contracting (NICEIC), throughout the UK, Tel: 0171 582 7746.
2.4.2. The Electrical Contractors Association (ECA), England and Wales, Tel: 0171 229 1266.
2.4.3. The Electrical Contractors Association of Scotland (ECAS), Tel: 0131 445 5577.
2.6.1. Institute of Plumbing (IOP), throughout the UK, Tel: 01708 472791.
2.6.2. National Association of Plumbing, Heating and Mechanical Services
Contractors (NAPH & MSC), England and Wales, Tel: 01203 470626.
2.6.3. Scottish and Northern Ireland Plumbing Employers’ Federation (SNIPEF), Scotland and Northern Ireland, Tel: 0131 225 2255.
6
Tick the appropriate boxes to familiarize yourself with the part names and to confirm that the parts are included.
Section
3
Pack Contents Checklist
1. Mira Sport 10.8 kW
2. Documentation
1 x Installation, Operation and Maintenance Guide 1 x Installation Template 1 x Customer Support Brochure
1 x Mira Sport 10.8
3 x Wall Plug
1 x Compression Nut
1 x Olive
3 x Fixing Screws
7
Section
4
Dimensions
342 mm
203 mm
76 mm
8
Section
5
Wiring Diagram
Thermal Cutout Dual Disc
Tank Connection
Overheat
P
E
N
Solenoid Valve
Pressure Switch
Relay PCB
Inlet Connector
89 Brown
91 Green
90 Blue
92 Green
Stop
85 Red
87 Brown
98 Blue
Load
Brown
Black
Black
Green Blue
Red
9
Section
6
Specifications
1. Plumbing
1.1. Minimum maintained inlet pressure 1.0 bar for satisfactory operation.
1.2. Maximum static inlet pressure 10 bar.
1.3. Minimum static pressure 0.2 bar to keep the flow valve closed.
2. Electrical
2.1. The Mira Sport requires a 45 Amp fuse.
2.2. The terminal block will not accept cable larger than 16 mm2 .
3. Standards and Approvals
3.1. The Mira Sport has been designed to comply with the requirements of the British Electrotechnical Approvals Board (BEAB) and UK Water Regulations/Bylaws (Scotland)
.
3.2. This Mira Sport complies with all relevant directives for CE marking.
10
Section
7
Installation Requirements
1. Plumbing
1.1. The Mira Sport is designed to operate with a minimum maintained inlet pressure of 1.0 bar up to a maximum static inlet pressure of 10 bar.
1.2. The Mira Sport is normally connected to the cold water mains-fed supply.
However, the water supply can be taken from a cold water storage cistern, provided there is a minimum maintained inlet head of water of 10 metres (the vertical distance from the base of the cold water storage cistern to the shower fitting handset). The cistern-fed water supply must be independent from other supply draw-offs, and should avoid long horizontal pipe runs and use swept bends rather than 90° elbows.
1.3. The Mira Sport is suitable for installation within the shower area. It must be positioned over a water catchment area with the controls at a convenient height for the user.
1.4. The Mira Sport is fitted with a brass inlet connector assembly intended to connect to a 15 mm compression fitting supplied from the top, bottom or back.
1.5. Do not fit the Mira Sport to the wall and tile up to the case. The Mira Sport must be fitted on to the finished flat and even wall surface. This is important as difficulty may be encountered when fitting the cover and subsequent operation of the unit could be impaired (Small pillars moulded on to the back of the case allow air circulation).
1.6. Refrain from applying excessive force when making any connections. Always provide mechanical support when making the plumbing connections.
1.7. Do not install the Mira Sport in a position where it may become frozen. The shower unit must not be fitted where it may be exposed to freezing conditions. The shower unit must not be used if suspected of being frozen.
1.8. We recommend that a non-restrictive (free flowing) isolating valve is fitted in the cold water supply pipe to allow the complete maintenance of the Mira Sport. Do not use a valve with a loose washer plate (jumper).
1.9. To avoid damage to the case when soldered fittings are used, pre-solder the pipework and fittings before connecting them to the inlet connector assembly.
1.10. The Mira Sport is fitted with a ½ " BSP male outlet thread, to accept a Mira shower hose.
11
1.11. Supply pipework MUST be flushed to clear debris before connecting the Mira Sport.
1.12. When installed in very hard water areas (above 200 ppm temporary hardness) your installer may advise the installation of a water treatment device, to reduce the effects of limescale formation. Mira Sport malfunction due to excessive limescale formation is not covered by the manufacturer’s guarantee. Your local water company will be able to advise the hardness of water in your area.
1.13. A hose retaining ring is supplied to prevent the handset from dropping below the spillover level of the bath or shower, which could lead to contamination from backsiphonage (refer to Figure 1). The supplied hose retaining ring should meet the great majority of user requirements for shower installations with flexible outlet fittings. However, there will be occasions when the hose retaining ring will not provide a suitable solution. In these instances an outlet double checkvalve, e.g. the Mira DCV-H, must be fitted. The inclusion of the Mira DCV-H will increase the required supply pressure typically by 0.1 bar.
Double checkvalves, fitted in the inlet supply to the appliance, cause a pressure buildup, which could exceed the maximum static inlet pressure for the appliance.
1.14. Avoid layouts where the shower hose will be sharply kinked. This may reduce the life of the hose.
Hose Retaining Ring
25 mm Minimum
Spill-over Level
2. Electrical
2.1. In a domestic installation, the rating of the electricity supply company fuse and the consumer unit must be adequate for the additional demand. As these Mira Sports are high power units, it is essential to contact your electricity supply company to ensure that the supply is adequate for the Mira Sport. Voltage drop due to local heavy demand will reduce the shower's performance.