Mira MYLINE User Manual

Page 1
THERMOSTATIC MIXER
INSTALLATION & USER GUIDE
These instructions must be left with the user.
1
MIRA MYLINE
Page 2
CONTENTS
Introduction 2
Guarantee 2
Patents and Design Registration 3
Safety Warnings 4
Pack Contents 5
Specications 6
Pressures 6
Temperatures 6
Thermostatic Shut-down 6
Connections 6
Dimensions 6
Installation 7
Suitable Plumbing Systems 7
General 7
Flow Regulator 7
Installing the Thermostatic Mixer 8
Commissioning 10
Maximum Temperature Setting 10
Installing the Shower Fittings 11
Operation 13
Flow Control 13
Temperature Control 13
User Maintenance 15
Fault Diagnosis 15
Lubricants 15
Cleaning 15
Spray Plate Assembly 16
Cloud Spray Plate Assembly 16
Spare Parts 17
Accessories 19
CustomerService 20
INTRODUCTION
Thank you for purchasing a quality Mira product. To enjoy the full potential of your new product, please take time to read this guide thoroughly, having done so, keep it handy for future reference.
The Mira MyLine is a thermostatic mixer which
has separate ow and temperature controls.
The Mira MyLine is an exposed valve with an integral slidebar and hose to a 360 Showerhead.
The thermostatic mixer incorporates a wax capsule temperature sensing unit, which provides an almost immediate response to changes in pressures or temperature of the incoming water supplies to maintain the selected temperature. An adjustable maximum temperature stop is provided which limits the temperature to a
safe level. Inlet lters are tted to protect the
thermostatic mechanism.
Guarantee
For domestic installations, Mira Showers guarantee the Mira MyLine against any defect in materials or workmanship for a period of ve years from the date of purchase and the shower ttings for one year.
For terms and conditions refer to the back cover of this guide.
If you experience any difficulty with the installation or operation of your new thermostatic mixer, please refer to ‘Fault Diagnosis’, before contacting Mira Showers. Our contact details can be found on the back cover of this guide.
2
Page 3
Recommended Usage
Application
Domestic
Light Commercial
Heavy Commercial
Healthcare
Valve with
Fittings
ü
û
û
û
Patents and Design Registration
Patents:
GB 2 340 210
GB 2 392 223
GB 2 422 886
European 1 672 257 (DE, FR, GB, IT, NL, SE)
Germany 60 2005 002 339.9
Patent Applications:
European 07015846.4
US - 2006 - 0124758 - A1
US - 2010 - 0123013 - A1
US - 2010 - 0219255 - A1
Design Registration:
GB 001240527 - 0001
3
Page 4
SAFETY WARNINGS
Mira thermostatic mixers are precision engineered and should give continued safe and controlled performance, provided:
1. They are installed, commissioned, operated and maintained in accordance with manufacturer’s recommendations.
2. Periodic attention is given, when necessary, to maintain the product in good functional order.
Caution!
1. Read all of these instructions.
2. Retain this guide for later use.
3. Pass on this guide in the event of change of
ownership of the installation site.
4. Follow all warnings, cautions and instructions contained in this guide.
5. Anyone who may have difculty understanding
or operating the controls of any shower should be attended whilst showering. Particular consideration should be given to the young,
the elderly, the inrm or anyone inexperienced
in the correct operation of the controls.
6. Rapid/Excessive movement of the ow and/
or temperature control levers may result in momentary unstable blend temperatures.
7. Care is required when adjusting flow or temperature. Make sure that the temperature has stabilised.
8.
Do not remove or tighten the body grubscrews.
9. Care must be taken when positioning the thermostatic mixer. Make sure that there is
sufcient headroom and ceiling clearance to
install the integral slidebar and Showerhead.
10. When this product has reached the end of its serviceable life, it should be disposed of in a safe manner, in accordance with current local authority recycling, or waste disposal policy.
Caution! Do not remove or tighten these grubscrews.
4
Page 5
PACK CONTENTS
Tick the appropriate boxes to familiarise yourself
with the part names and to conrm that all of the
parts are included.
Mira MyLine Mixer Mira MyLine Shower Fittings
q 1 x Concealing Plate
q 1 x M4 x 12 mm Grubscrew
q 2 x Olives
q 1 x Thermostatic Mixer
(supplied tted to the backplate)
q 4 x Wall Plugs
q 1 x Wall Plugs
q 1 x Wall Bracket
q 1 x Fixing
Screw
q 1 x Clamp
Bracket
q 1 x Slide Bar
q 1 x Securing Screw
q 1 x Slidebar Support
q 1 x 360m
Showerhead
q 1 x Shower Hose
1.25 m Chrome (supplied with 2x Sealing Washers)
q 1 x Hose Retaining
Ring
q 4 x Fixing Screws
q 1 x 2 mm Hexagonal Key
Documentation
q 1 x Guarantee Registration Document
q 1 x 3 mm Hexagonal
Key
5
Page 6
SPECIFICATIONS
Pressures
Max Static Pressure: 10 Bar.
Max Maintained Pressure: 5 Bar.
Min Maintained Pressure (Gravity System):
0.1 Bar (0.1 bar = 1 Metre head from cold tank base to showerhead outlet).
Note! For gravity fed / other low pressure systems (0.5 bar or below) remove the outlet
ow regulator. Refer to section: ‘Installation, Flow Regulator’.
For optimum performance supplies should be
nominally equal.
Temperatures
Factory Pre-set (Blend) Shower: 43°C.
Optimum Thermostatic Control Range: 35°C
to 43°C (achieved with supplies of 15°C cold, 65°C hot and nominally equal pressures).
Recommended Hot Supply: 60°C to 65°C
Note! The mixing valve can operate at higher temperatures for short periods without damage, however this could detrimentally affect thermostatic performance. For safety and performance reasons it is recommended that the maximum hot water temperature is limited to 65°C.
Cold Water Range: up to 25°C.
Minimum Recommended Differential between
Hot Supply and Outlet Temperature: 12°C.
Thermostatic Shut-down
For safety and comfort the thermostat will
shut off the mixing valve within 2 Seconds if either supply fails (achieved only if the blend temperature has a minimum differential of 12°C from either supply temperature).
Connections
The thermostatic mixer can only be installed with rear supply inlets and the supply pipework must be connected as follows:
Cold: Top (side nearest temperature control),
15 mm compression.
Hot: Bottom (side nearest ow control), 15
mm compression.
Outlet: 15 mm at face to hose.
Note! This product does not allow for reversed inlets and will deliver unstable temperatures if
tted incorrectly.
Cold
Dimensions
All dimensions in mm
6
42
Outlet
188
Hot
780
720 (To Screw Hole)
107
59
57
Page 7
INSTALLATION
Suitable Plumbing Systems
GravityFed:
The thermostatic mixer must be fed from a cold
water cistern (usually tted in the loft space) and a hot water cylinder (usually tted in the airing
cupboard) providing nominally equal pressures.
Mains Pressurised Instantaneous Hot Water System (Combination Boiler):
The thermostatic mixer can be installed with systems of this type with balanced pressures. (Recommended Minimum Maintained Pressure:
1.0 Bar).
UnventedMainsPressureSystem:
The thermostatic mixer can be installed with an unvented, stored hot water system.
Pumped System:
The thermostatic mixer can be installed with an inlet pump (twin impeller). The pump must be installed in a suitable location and in accordance with its instructions.
6. Decide on a suitable position for the Mixer,
make sure that there is sufcient headroom
and ceiling clearance to install the integral slidebar rail and Showerhead.
The position of the Mixer and the Shower
Fittings must provide a minimum gap of 25 mm between the spill-over level of the shower tray/ bath and the showerhead (refer to illustration). This is to prevent back-siphonage.
Note! Only use Shower Fittings recommended
by the manufacturer or supplier.
25 mm Spill Over Level
General
Installation must be carried out in accordance with these instructions, and must be conducted by
designated, qualied and competent personnel.
The installation must comply with the “Water Supply Regulations 1999 (Water Fittings)” or any
particular regulations and practices, specied by
the local water company or water undertakers. Note! Make sure that all site requirements
correspond to the information given in section: ‘Specications’.
1. The Mixer must not be installed in an area where it may freeze.
2. For stud partitions alternative xings may be
required.
3. Isolating valves must be installed close to the Mixer for ease of maintenance.
4. Pipework must be rigidly supported and avoid any strain on the connections.
5. Pipework dead-legs should be kept to a minimum.
Flow Regulator
Site conditions will determine the ow regulator
requirements. For gravity fed / other low pressure systems
(0.5 bar or below) remove the outlet ow regulator.
Flow regulators are supplied with this product
and should be tted in High Pressure systems
to either;
1. Reduce Excessive Force and Flow Rate
2. Reduce Noise through the mixer due to
high or unequal pressures
3. Stabilise incoming supply temperatures
7
Page 8
Installing the Thermostatic Mixer
1. The thermostatic mixer must be tted vertically
as illustrated and can only be installed with rear supply inlets. The supply pipework must be connected as follows:
Cold to Top Inlet
Hot to Bottom Inlet
Bottom Outlet.
Important! This product does not allow for reversed inlets.
2. Determine the route for the hot and cold supply pipework.
Important! Make sure that there is sufcient
headroom and ceiling clearance to install the integral slidebar.
Cold
Hot
Backplate
Inlet Nuts
Grubscrew
5. Using the backplate as a guide, mark the
positions of the xing holes and the pipe
centres.
Important! Make sure that there is sufcient
headroom and ceiling clearance to install the integral slidebar.
Note! Make sure that the backplate is the
correct way up (refer to illustration).
Concealing Plate
Outlet
3. Loosen the 2 backplate grubscrews with the
2 mm hexagonal key (supplied) and pull the mixer and concealing plate from the backplate.
4. Unscrew the inlet nuts from the backplate.
Large boss must be
tted at the bottom
8
Page 9
6. For solid walls drill the xing holes for the
backplate with a 6 mm drill and insert the wall plugs (supplied). For other types of wall
structure alternative xings may be required
(not supplied).
7. Drill the holes for the supply pipes and t the
supply pipework:
Cold to Top Inlet, Hot to Bottom Inlet Note! The inlet pipework should extend
between 12 and 18 mm from the nished wall
surface.
Caution! Make sure that the pipework is not
damaged otherwise the olives will not seal.
8. Fit the backplate over the inlet pipes and
secure to the wall using the xing screws
(supplied).
9. Caution! It is essential at this point that the supply pipework is thoroughly
ushedthroughbeforeconnectiontothe
mixer. Failure to do so may result in product malfunction and will not be covered under the guarantee.
10. Fit the olives onto the inlet pipework and tighten the inlet nuts using a suitable spanner.
Caution! Do not overtighten. Important! Make sure that the inlet lters are
tted in the inlet nuts as illustrated.
Fixing Screws
11. Make sure that the concealing plate (with
the hole at the bottom) is loosely tted over
the mixing valve inlets and align the mixer with the inlet nuts. Push on fully and tighten the grubscrews to secure the mixer to the backplate. Make sure that the grubscrews are engaged fully in the valve body grooves.
Concealing Plate
Inlet Filters
12. Push the concealing plate onto the backplate, secure with the M4 x 12 mm grubscrew.
Single grubscrew secures the top inlet to the backplate
Hot Inlet
Cold Inlet
Olive
Large boss must be
tted at the bottom
Inlet Nut
Filter
Two grubscrews secure both the bottom inlet and the concealing plate to the backplate
9
Page 10
13. Important! A 12 litre/minute ow regulator is tted inside the outlet This can be removed
for gravity fed / other low pressure systems (0.5 bar or below).
14. Temporarily install the hose and showerhead and commission the mixing valve.
Note! The mixing valve must be Commissioned
before the final installation of the shower
ttings.
Securing Screw (Access required for temperature setting)
COMMISSIONING
Maximum Temperature Setting
Before using the shower the maximum temperature must be checked to make sure that it is at a safe level. It has been preset to approximately 43°C at the factory but due to variations in site conditions the maximum temperature may need adjustment.
Note! Make sure that the hot water temperature
is at least 55°C and that there is sufcient supply.
1. Turn on the mixer to the maximum temperature
(i.e. fully clockwise)and full ow, and allow the
temperature to stabilise.
2. Test that the temperature of the water from the shower outlet is hot enough.
If the temperature is too hot or too cold adjust
as follows:
3. Loosen the securing screw (do not remove fully) and lift up the temperature lever to disengage from the control gear.
4. Rotate the temperature lever anti-clockwise (one serration), re-engage with the control gear and return to the maximum temperature stop. Check the temperature, if it is still not hot enough repeat the procedure.
5. Once the maximum temperature is satisfactory, tighten the securing screw.
Securing Screw
Temperature Control Lever
Note! Ensure the sealing washers are installed
into the hose.
Pull down and rotate the temperature lever to adjust the maximum temperature
6. After commissioning of the mixing valve is complete, remove the showerhead.
10
Page 11
Installing the Shower Fittings
1. Install the hose retaining ring, clamp bracket
and the slidebar support onto the slidebar.
Note! Some components may already be
pre-assembled.
Slidebar Support
700 mm Slidebar
Clamp Bracket
3. Temporary install the slidebar assembly into the thermostatic mixing valve.
4. Using the wall bracket as a guide, mark the
position of the bottom xing hole for the wall
bracket.
Note! The distance from the top of the
concealing plate to the screw hole on the wall bracket is 720 mm.
Note! Use a spirit level to make sure that the
wall bracket is vertical.
Hose Retaining Ring
2. Temporary install the wall bracket into the slide bar support.
Note! Use the wall bracket as a guide to mark
the position of the screw hole.
Slidebar Support
Screw Hole
Wall Bracket
720 mm
720 To Screw
Hole
5. After marking the position for the wall bracket remove the slidebar assembly from the thermostatic mixing valve.
6. Drill one Ø8 mm fixing hole for the wall brackets at 720 mm from the top of the concealing plate, and insert the wall plug.
Screw Hole
11
Page 12
7. Install the wall bracket and fully tighten the
xing screw.
Note! The slot in the wall bracket allow for
minor adjustment.
10. Pass it through the hose retaining ring and install the showerhead onto the hose.
Note! Ensure that the sealing washers are
installed into the hose.
8. Install the slidebar assembly into the thermostatic mixing valve.
9. Position the slidebar support over the wall bracket and secure with the securing screw as indicated.
Wall Bracket
Wall Plug
Fixing Screw
Clamp Bracket
Slide Bar
11. Place the showerhead onto the clamp bracket.
12. Turn on the water and check for any leaks.
Securing Screw
Slidebar Support
Showerhead
Sealing Washer
12
Hose Retaining Ring
Hose
Sealing Washer
Page 13
OPERATION
Flow Control
Turn the ow lever anticlockwise to the maximum ow.
Note! This shower is intended to be used with
the ow control fully open. If excessive water ow is experienced at the Showerhead then the ow regulator should be tted.
Temperature Control
Turn the temperature control lever anticlockwise to decrease the temperature and clockwise to the preset maximum temperature
+
Temperature Control
-
Off
On
Flow Control
Height Adjustment
The height of the showerhead is easily adjusted by gently moving the clamp bracket either up or down the slide bar until the required height is achieved.
13
Page 14
Changing the Spray Setting
The 360 Showerhead has four different spray actions:- Rain, Cloud, Storm and Burst. The showerhead features a rotating head to enable differing spray patterns to be achieved, turn the showerhead in the
direction shown to activate the different spray patterns.
1
8
2
Rain
7
Cloud Burst
6
5
4
3
Storm
14
Page 15
USER MAINTENANCE
If you require a Mira trained service engineer or agent, refer to section: ‘CustomerServices’.
Fault Diagnosis
Symptom:
• Only hot or cold water from the mixer outlet.
• Outlet temperature too hot / too cold.
CauseRectication:
• Inlets reversed (hot supply to cold supply).
Rework inlet pipework.
• No hot water reaching mixer.
• Checktheltersforanyblockage.
• Installation conditions outside operating
parameters, refer to sections: ‘Specications’ and ‘Commissioning’.
• Ifthetemperatureistoocoldandyouhave
a combination type boiler it may not be
producingsufcientlyhotwateratdesired ow rate (refer to ‘Specications’). Fit owregulator(supplied)toshowervalve
outlet. For more information contact Mira
Showersorvisitthewebsite.
—————————————
Symptom:
• Fluctuatingorreducedowrate.
CauseRectication:
• Checkthe showerhead,hoseandltersfor
anyblockage.
• Make sure that the maintained inlet pressures
arenominally balancedandsufcient,refer
to section: ‘Specications’.
• Make sure that the inlet temperature
differentials are sufcient, refer to section:
‘Specications’.
• Flowregulatorttedincorrectly.
• Airlockorpartialblockageinthepipework.
—————————————
Symptom:
• Water leaking from showerhead.
CauseRectication:
• Normal for a short period after shut off.
• Check that the pressures are not in excess of
thespecicationsfortheproduct.
• Renewthemixervalveassembly.
Lubricants
Silicone based lubricants must only be used on the rubber seals.
Caution! Oil based or other lubricant types may cause rapid deterioration of seals.
Cleaning
The chrome plated parts should be cleaned using a mild washing up detergent or soap solution, rinsed and then wiped dry with a soft cloth.
Warning! Many household cleaners contain abrasive and chemical substances, and should
not be used for cleaning plated or plastic ttings. These nishes should be cleaned with a mild
washing up detergent or soap solution, and then wiped dry using a soft cloth.
Use your thumb or a soft cloth to wipe any limescale from the soft nozzles and the front surface of the showerhead spray plate.
Do not use descalents on this product.
Spray Plate
1. Use your thumb or a soft cloth to wipe any
limescale from the soft rubber nozzles and the front face of the spray plate assembly
Important! The sprayplate must be regularly
cleaned to make sure that the showerhead does not become blocked.
Use your thumb or a soft cloth to wipe any limescale from the soft nozzles
15
Page 16
Spray Plate Assembly
1. Use a suitable tool to remove the grommets.
2. Using the 2.5 mm hexagonal wrench (supplied), remove the screws.
3. Separate the sprayplate assembly into its individual components.
4. Clean or replace components as necessary.
Note! Make sure that the seals are located
correctly.
5. Reassemble the components in reverse order.
Grommet
Screws
Seals
Seals
Cloud Spray Plate Assembly
This product is supplied configured for the majority of showering systems including electric showers.
Note! for showers with a pressure of below 0.15 bar (1.5 metre head) it might be necessary to change the Cloud sprayplate assembly for the LC (Low Capacity) version in order to achieve a suitable spray pattern.
Caution! The LC sprayplate must not be used on electric showers
1. Use a suitable tool to remove the grommets.
2. Using the 2.5 mm hexagonal wrench (supplied), remove the screws.
3. Separate the sprayplate assembly into its individual components.
4. Replace the Cloud assembly sprayplate with the LC version.
5. Reassemble the components in reverse order.
Grommet
Seals
Screws
Replacing the Sprayplate or Seals
Low Capacity Sprayplate
Replacing the Cloud Sprayplate Assembly
16
Seals
Page 17
SPARE PARTS
1660.150 Backplate
1660.151 Concealing Plate
1660.153 Inlet Nuts & Olives (x2)
1660.152 Filter Pack (x2)
1778.019 Shroud Pack
1660.155 Temperature Lever Pack
1778.018 Mixer Valve Assembly
1660.157 Flow Lever Pack (also includes Securing Nut)
1660.150 Backplate
1660.151 Concealing Plate
1660.152 Filter Pack
1660.153 Inlet Nuts and Olive
1660.155 Temperature Lever Pack (Top)
1660.157 Flow Lever Pack (Bottom)
1778.018 Mixer Valve Assembly
1778.019 Shroud Pack
Not illustrated:
1660.159 Screw Pack
1660.175 Seal Pack
1663.265 Flow Regulator Pack
1778.019 Shroud Pack
17
Page 18
1778.022 Wall Bracket Assembly
1688.185 Clamp Bracket
1778.021 Slidebar
1688.200 360mShowerhead
1603.104 Shower Hose (includes 2 Washers)
1778.020 Hose Retaining Ring
1688.200 Showerhead
1603.104 Shower Hose
1688.160 Rain Assembly - White
1688.162 Storm Assembly - White
1688.164 Cloud Assembly - White
1688.166 Burst Assembly - White
1688.168 Seal & Screw Pack - Components Identied ‘A’
1688.184 Seal & Screw Pack - Components Identied ‘B’
1668.185 Clamp Bracket
1688.200 360m Showerhead
1688.275 Cloud Assembly - LC (Low Capacity) - White
1778.020 Hose Retaining Ring
18
A,B
A, B
1688.164
1688.275
1778.021 Slidebar
1778.022 Wall Bracket Assembly
1688.162
1688.166
A, B
1688.160
Page 19
ACCESSORIES
Genuine Mira accessories can be purchased direct from Customers Services (our contact details can be found on the back cover of this guide) or from approved stockists or merchants.
Eco Showerhead
White-2.1668.001 Chrome-2.1668.002
The Eco shower head gives you an invigorating shower, but reduces water consumption and heating costs.
Mira Standard Grab Bars
300mm-2.1605.070 450mm-2.1605.071 600mm-2.1605.072
Premium grade, highly polished, stainless steel grab bars. Note! Must be installed onto a solid wall.
EverclearShowerhead White-2.1616.030 Chrome-2.1616.031
Mira's new Everclear range has been specially designed for hard water areas and reduces the risk of lime scale build up.
Shower Seat
White-2.1536.128 White/Chrome-2.1536.129
For use in or out of the showering area. Folds up when not in use.
Maximum User Weight - 127 kg (20 stone) Note! Must be installed
onto a solid wall.
Wall Mounted Soap Dish White - 1.1540.278 Chrome - 1.1540.279
Wall mounted for use anywhere in, or outside the showering area.
Premium Shower Seat White/Chrome - 2.1731.001 Grey/Chrome - 2.1731.002
Stylish, slim-line and robust shower seat for use in or outside of the shower area. Folds up when not in use. Maximum User Weight
- 150 kg (23.5 stone) Note! Must
be installed onto a solid wall.
Checkvalve(360mand360r)-1688.282
19
Page 20
CUSTOMER SERVICE
Guarantee
Your pr oduct has the benefit of our manufacturer’s guarantee which starts from the date of purchase. To activate this guarantee, please return your completed registration card, visit our website or free phone 0800 0731248 within 30 days of purchase (UK only). Within the guarantee period we will resolve defects in materials or workmanship, free of charge, by repairing or replacing parts or product as we may choose. If you have not previously activated the guarantee, you will be required to do so prior to the provision of assistance. If you do not activate your guarantee our Engineer will be entitled to charge full payment for the visit (Call out fee plus parts).
This guarantee is in addition to your statutory rights and is subject to the following conditions:
● The product must be installed and maintained in accordance with the instructions given in this user guide.
● Servicing must only be undertaken by us or our appointed representative. Note! if a service visit is required the product must be fully installed and connected to services.
● Repair under t his guarantee does not e xtend the original expiry date. T he guarantee on any replacement parts or product ends at the original expiry date.
● For shower fi ttings or consumable items we reserve the right to supply replacement parts only.
The guarantee does not cover:
● Call out charges for non product faults (such as damage or performance issues arising from incorrect installation, improper use, lack of maintenance, build up of limescale, frost damage, corrosion, system debris or blocked fi lters) or where no fault has been found with the product.
● Water or electrical supply, waste and isolation issues.
● Compensation for loss of use of the product or consequential loss of any kind.
● Damage or defects caused if the product is repaired or modifi ed by persons not authorised by us or our appointed representative.
● Routine maintenance or replacement parts to comply with the requirements of the TMV 2 or TMV 3 healthcare schemes.
What to do if something goes wrong
If your product does not function correctly when you fi rst use it, contact your installer to check that it is installed and commissioned in accordance with the instructions in this manual. Should this not resolve the issue, contact our Customer Services Team who will offer you or your installer advice and if applicable arrange for a Service Technician to call. If the performance of your product declines, check in this manual to see if simple home maintenance is required. If you require further assistance call our Customer Services Team.
Extended Guarantees
A selection of protection plans are available that enable you to cover repair bills for the life of your policy (excludes Eire). Ring 01922 471763 for more details.
Helpdesk Service
Our dedicated Customer Services Team is comprehensively trained and can offer help and advice, spare parts, accessories or a service visit. We will need you to have your model name or number, power rating (if applicable) and date of purchase. As part of our quality and training programme calls may be recorded or monitored.
Mira Showers Website (www.mirashowers.co.uk)
From our website you can register your guarantee, download additional user guides, diagnose faults, purchase our full range of accessories and popular spares, refer to our FAQ’s and request a service visit.
Spares and Accessories
We maintain extensive stocks of genuine spares and accessories and aim to provide support throughout the product’s expected life. Payment can be made by phone at time of order using most major Credit or Debit cards and we aim to despatch orders within two working days. Items purchased from us are guaranteed for 12 months from date of purchase. For safety reasons spares exposed to mains voltages should only be fi tted by competent persons. Returns – items can be returned within one month of date of purchase, providing that they are in good condition and the packaging is unopened. Please obtain authorisation from our Customer Services Team before return. We reserve the right to apply a 15% restocking charge.
Service / Repairs
We have a nationwide team of Service Technicians who can carry out all service or repair work to y our product within the guarantee period and beyond. You have the assurance of a fully trained Mira Te chnician, genuine Mira spare parts and a 12 month guarantee on any chargeable work done. Payment should be made directly to the Service Technician who will accept most major Credit or Debit cards.
To Contact Us UK Telephone: 0844 571 5000 www.mirashowers.co.uk
E-mail: technical@mirashowers.com Fax: 01242 282595 By Post: Mira Customer Services Dept, Cromwell Road, Cheltenham, Gloucestershire, GL52 5EP
Eire Telephone: 01 459 1344
E-mail: sales@modernplant.ie Fax: Dublin 01 459 2329 By Post: Modern Plant Ltd (Dublin), Otter House, Naas Road, Clondalkin, Dublin 22
Mira is a registered trade mark of
Kohler Mira Limited.
The company reserves the right to alter
product specifi cations without notice.
1161644-W2-A (B94Eb) (1778) © Kohler Mira Limited, January 2011
20
Loading...