INTRODUCTION
The Mira Infuse and Mira Minibelle are thermostatic
mixers which have separate ow and temperature
The thermostatic mixers incorporate a wax capsule temperature sensing unit, which provides an almost immediate response to changes in pressures or temperature of the incoming water supplies, to maintain the selected temperature. An adjustable maximum temperature stop is provided which limits the temperature to a safe level.
Inlet lters are tted to protect the thermostatic
cartridge.
Patents
Patents:
GB: 2 340 210, 2 392 223, 2 392 224
Patent Applications
Euro: 1 672 257 US: 2006-0124758-A1
CONTENTS
Introduction 2
Patents 2
Safety Warnings 3
Pack Contents 3
Specications 4
Pressures 4
Temperatures 4
Thermostatic Shut-down 4
Connections 4
Dimensions 4
Installation 5
Suitable Plumbing Systems 5
General 5
Flow Regulator 5
Installing the Thermostatic Mixer 6
Commissioning 9
Maximum Temperature Setting 9
Operation 9
Temperature Control 9
Flow Control 9
User Maintenance 10
Fault Diagnosis 10
Lubricants 10
Cleaning 10
Spare Parts 11
Customer Service Back Page
If you experience any difficulty with the ins tallati on o r op era tion of your new thermostatic mixer, please refer to ‘Fault Diagnosis’, before contacting Kohler Mira Ltd. Our telephone and fax numbers can be found on the back cover of this guide.
Page 3
3
SAFETY WARNINGS
Mira thermostatic mixers are precision engineered and should give continued safe and controlled performance, provided:
1. They are installed, commissioned, operated and maintained in accordance with manufacturers recommendations.
2. Periodic attention is given, when necessary, to maintain the product in good functional order.
Caution!
1. Read all of these instructions.
2. Retain this guide for later use.
3. Pass on this guide in the event of change of
ownership of the installation site.
4. Follow all warnings, cautions and instructions contained in this guide.
5. Anyone who may have difculty understanding
or operating the controls of any shower should be attended whilst showering. Particular consideration should be given to the young,
the elderly, the inrm or anyone inexperienced
in the correct operation of the controls.
6. Rapid/Excessive movement of the ow and/
or temperature control levers may result in momentary unstable blend temperatures.
7. Care is required when adjusting flow or temperature, make sure that the temperature has stabilised.
8.
Do not remove or tighten the body grubscrews
.
Caution! Do not remove or tighten these grubscrews.
9. When this product has reached the end of its serviceable life, it should be disposed of in a safe manner, in accordance with current local authority recycling, or waste disposal policy.
PACK CONTENTS
Tick the appropriate boxes to familiarise yourself
with the part names and to conrm that all of the
parts are included.
q 1 x M4 x 12 mm Grubscrew
q 2 x Olives
q 4 x Wall plugs
q 4 x Fixing Screws
q 1 x 2 mm Hexagonal Key
q 1 x Thermostatic Mixer
(supplied tted to the backplate)
q 1 x Concealing Plate
Documentation
q 1 x Guarantee Registration Document
Page 4
4
Dimensions
Ø47
107
59
174
Ø42
51
All dimensions in mm
SPECIFICATIONS
Pressures
Max Static Pressure: 10 Bar. Max Maintained Pressure: 5 Bar.
Min Maintained Pressure (Gravity System):
0.1 Bar. (0.1 bar = 1 Metre head from cold
tank base to shower handset outlet).
Note! For gravity fed / other low pressure
systems (0.5 bar or below) remove the outlet ow regulator. Refer to section: ‘Installation,
Flow Regulator’.
For optimum performance supplies should be
nominally equal.
Temperatures
Factory Pre-set (Blend) Shower: 43°C. Optimum Thermostatic Control Range: 35°C
to 43°C (achieved with supplies of 15°C cold,
65°C hot and nominally equal pressures).
Recommended Hot Supply: 60°C to 65°C
Note! The mixing valve can operate at higher temperatures for short periods without damage, however this could detrimentally affect thermostatic performance. For safety and performance reasons it is recommended that the maximum hot water temperature is limited to 65°C.
Cold Water Range: up to 25°C. Minimum Recommended Differential between
Hot Supply and Outlet Temperature: 12°C.
Thermostatic Shut-down
For safety and comfort the thermostat will
shut off the mixing valve within 2 Seconds if either supply fails. (achieved only if the blend temperature has a minimum differential of
12°C from either supply temperature).
Connections
The thermostatic mixer can only be installed with rear supply inlets and the supply pipework must be connected as follows:
Hot: Bottom (side nearest flow control),
15 mm compression.
Cold: Top (side nearest temperature control),
15 mm compression.
Outlet: ½” BSP Male to exible hose.
Note! This product does not allow for reversed inlets and will deliver unstable temperatures if
tted incorrectly.
Hot Cold
Outlet
Page 5
5
INSTALLATION
Suitable Plumbing Systems
Gravity Fed:
The thermostatic mixer must be fed from a cold
Mains Pressurised Instantaneous Hot Water System (Combination Boiler):
The thermostatic mixer can be installed with systems of this type with balanced pressures. (Recommended Minimum Maintained Pressure:
1.0 Bar).
Unvented Mains Pressure System:
The thermostatic mixer can be installed with an unvented, stored hot water system.
Pumped System:
The thermostatic mixer can be installed with an
inlet pump (twin impeller). The pump must be
installed in a suitable location and in accordance with its instructions.
General
Installation must be carried out in accordance with these instructions, and must be conducted by
designated, qualied and competent personnel.
Supply Regulations 1999 (Water Fittings)” or any particular regulations and practices, specied by
the local water company or water undertakers. Note! Make sure that all site requirements
1. The Mixer must not be installed in an area where it may freeze.
2. For stud partitions alternative xings may be
required.
3. Isolating valves must be installed close to the Mixer for ease of maintenance.
4. Pipework must be rigidly supported and avoid any strain on the connections.
5. Pipework dead-legs should be kept to a minimum.
6. Decide on a suitable position for the Mixer. The position of the Mixer and the Shower Fittings must provide a minimum gap of 25 mm between the spill-over level of the shower
tray/bath and the handset (refer to illustration).
This is to prevent back-siphonage. For further information on the installation of your Shower Fittings, refer to the Fittings Installation and User Guide.
Note! Only use Shower Fittings recommended
by the manufacturer or supplier.
25 mm Spill Over Level
Flow Regulator
Site conditions will determine the ow regulator
requirements. For gravity fed / other low pressure systems
(0.5 bar or below) remove the outlet flow
regulator.
Hose Washer
Outlet Flow Regulator
Page 6
6
Installing the Thermostatic Mixer
1. The thermostatic mixer must be tted vertically
as illustrated and can only be installed with rear supply inlets. The supply pipework must be connected as follows:
Hot to Bottom Inlet Cold to Top Inlet Bottom Outlet.
Important! This product does not allow for reversed inlets.
2. Determine the route for the hot and cold supply pipework.
Hot Cold
Outlet
4. Loosen the 2 backplate grubscrews with
the 2 mm hexagon key (supplied) and pull
the mixer and concealing plate from the backplate.
5. Unscrew the inlet nuts from the backplate.
Concealing Plate
Backplate
Inlet Nuts
6. Using the backplate as a guide, mark the positions of the fixing holes and the pipe centres.
Note! Make sure that the backplate is the
correct way up (refer to illustration).
Large boss must be
tted at the bottom
Page 7
7
7. For solid walls drill the xing holes for the
backplate with a 6 mm drill and insert the
wall plugs (supplied). For other types of wall structure alternative xings may be required (not supplied).
8. Drill the holes for the supply pipes and t the
supply pipework:
Hot to Bottom Inlet, Cold to Top Inlet Note! The inlet pipework should extend
between 12 and 18 mm from the nished wall
surface.
Caution! Make sure that the pipework is not
damaged otherwise the olives will not seal.
9. Fit the backplate over the inlet pipes and
secure to the wall using the xing screws (supplied).
Note! Make sure that the backplate is the
correct way up (refer to illustration).
10. Caution! It is essent ial at this p oi nt that the supply pipework is thoroughly
ushedthroughbeforeconnectiontothe
mixer. Failure to do so may result in product malfunction and will not be covered under the guarantee.
11. Fit the olives onto the inlet pipework and tighten the inlet nuts using a suitable spanner.
Caution! Do not overtighten. Important! Make sure that the inlet lters are
tted in the inlet nuts as illustrated.
Filter
Fixing Screws
Cold Inlet
Hot Inlet
Inlet Nut
Olive
Large boss must be
tted at the bottom
12. Make sure that the concealing plate (with
the hole at the bottom) is loosely tted over
the mixing valve inlets and align the mixer with the inlet nuts. Push on fully and tighten the grubscrews to secure the mixer to the backplate. Make sure that the grubscrews are engaged fully in the valve body grooves.
Concealing Plate
Inlet Filters
13. Push the concealing plate onto the backplate, secure with the M4 x 12 mm grubscrew.
Single grubscrew secures the top inlet to the backplate
Two grubscrews securing both the bottom inlet and the concealing plate to the backplate.
Page 8
8
14. Fit the shower ttings, refer to your shower
fittings i nstal latio n and user guide for instructions.
Important! A 12 litre/minute ow regulator
is tted inside the outlet nipple. This can be
removed for gravity fed / other low pressure
systems (0.5 bar or below).
Hose Washer
12 L/Min Flow Regulator
15. Turn on the hot and cold water supplies and check for leaks.
16. Before using the shower, refer to section: ‘Commissioning’.
Page 9
9
COMMISSIONING
Maximum Temperature Setting
Before using the shower the maximum temperature must be checked to make sure that it is at a safe level. It has been preset to approximately 43°C at the factory but due to variations in site conditions the maximum temperature may need adjustment.
Note! Make sure that the hot water temperature is
at least 55°C and that there is sufcient supply.
1. Turn on the mixer to the maximum temperature
(i.e. f ully anti clockwise ) and allow the
temperature to stabilise.
2. Test that the temperature of the water from the shower outlet is hot enough.
If the temperature is too hot or too cold adjust
as follows:
3. Carefully remove the concealing cap using a
suitable tool (i.e. stanley knife / thin blade).
4. Unscrew the securing screw and remove the temperature lever bearing.
5. Lift the temperature lever and move it back one serration on the temperature control gear.
6. Return the lever to the maximum temperature stop and check the temperature, if it is still not hot enough repeat the procedure.
Lift the temperature lever and move back one serration
Concealing Cap
Temperature Lever Bearing
Re-engage with the control gear and return to the maximum temperature stop
Securing Screw
Rubber Seal
Stanley Knife / Thin Blade
7. Once the maximum temperature is satisfactory,
ret the temperature control bearing and t and
tighten the securing screw.
8. Ret the concealing cap, make sure that the rubber seal is correctly tted.
OPERATION
Caution! Care is required when adjusting ow
or adjusting temperature. Make sure that the temperature has stabilised.
The thermostatic mixers have separate control
levers for temperature and ow.
Temperature Control
Turn the temperature control lever clockwise to decrease the temperature and anticlockwise to the preset maximum temperature
On
-
+
Off
Flow Control
Turn the ow lever clockwise to the maximum ow.
Page 10
10
USER MAINTENANCE
If you require a Mira trained service engineer or agent, refer to section: ‘Customer Services’.
Fault Diagnosis
Symptom:
Only hot or cold water from the mixer outlet.• Outlet temperature too hot / too cold.•
CauseRectication:
Inlets reversed (hot supply to cold supply). •
Rework inlet pipework.
No hot water reaching mixer.•
Checktheltersforanyblockage.•
Installation conditions outside operating •
parameters, refer to sections: ‘Specications’ and ‘Commissioning’.
—————————————
Symptom:
Fluctuatingorreducedowrate.•
CauseRectication:
Checktheshowerhandset,hoseandlters•
foranyblockage.
Make sure that the maintained inlet pressures •
arenominallybalanced andsufcient,refer
to section: ‘Specications’.
Make sure that the inle t t emper ature •
differentialsare sufcient,refer to section:
‘Specications’.
Flowregulatorttedincorrectly.• Airlockorpartialblockageinthepipework.•
—————————————
Symptom:
Water leaking from shower handset.•
CauseRectication:
Normal for a short period after shut off.• Check that the pressures are not in excess of •
thespecicationsfortheproduct.
Renewthemixervalveassembly.•
Lubricants
Silicone based lubricants must only be used on the rubber seals.
Caution! Oil based or other lubricant types may cause rapid deterioration of seals.
Cleaning
The chrome plated parts should be cleaned using a mild washing up detergent or soap solution, rinsed and then wiped dry with a soft cloth.
Warning! Many household cleaners contain abrasive and chemical substances, and should not
be used for cleaning plated or plastic ttings. These nishes should be cleaned with a mild
washing up detergent or soap solution, and then wiped dry using a soft cloth.
Use your thumb or a soft cloth to wipe any limescale from the soft nozzles and the front surface of the handset spray plate.
Do not use descalents on this product.
Page 11
11
SPARE PARTS
1660.157
Flow Knob Pack (Minibelle)
(also includes Securing Nut)
1660.158
Flow Knob Pack (Infuse)
(also includes Securing Nut)
1660.155 Temperature Knob
Pack (Minibelle)
1660.156 Temperature Knob
Pack (Infuse)
1660.150 Backplate
1660.151 Concealing Plate
1660.154 Mixer Valve Assembly
1660.153
Inlet Nuts & Olives (x2)
1660.152
Filter Pack (x2)
Not illustrated:
1660.159 Screw Pack
1660.175 Seal Pack
1660.169 Outlet Shroud and
Securing Nut (Infuse)
1660.168 Outlet Shroud and
Securing Nut (Minibelle)
1663.213 12 L/Min Flow Regulator
Page 12
12
CUSTOMER SERVICE
Guarantee of Quality
Mira Showers guarantee your product against any defect in materials or workmanship for the period shown in the Guarantee Registration Document included with your shower. Alternatively, to confi rm the applicable guarantee period please contact Customer Services. To validate the guarantee, please return your completed registration card. Within the guarantee period we will resolve defects, free of charge, by repairing or replacing parts or modules as we may choose. To be free of charge, service work must only be undertaken by Mira Showers or our approved agents. Service under this guarantee does not affect the expiry date. The guarantee on any exchanged parts or product ends when the normal product guarantee period expires.
Not covered by this guarantee:
Damage or defects arising from incorrect installation, improper use or lack of maintenance, including build-up of limescale. Damage or defects if the product is taken apart, repaired or modifi ed by any persons not authorised by Mira Showers or our approved agents. This guarantee is in addition to your statutory and other legal rights.
What to do if something goes wrong
If when you first use your shower, it doesn’t function correctly, fi rst contact your installer to check that installation and commissioning are satisfactory and in accordance with the instructions in this manual. We are on hand to offer you or your installer any advice you may need. Should this not resolve the diffi culty, simply contact our Customer Services Te am who will give every assistance and, if necessary, arrange for our service engineer to visit. If the performance of your shower declines, consult this manual to see whether simple home maintenance is required. Please call our Customer Services Team to talk the diffi culty through, request a service under guarantee if applicable, or take advantage of our comprehensive After-Sales service. As part of our quality and training programme calls may be recorded or monitored. Our Customer Services Team is comprehensively trained to provide every assistance you may need: help and advice, spare parts or a service visit.
Spare Parts
We maintain an extensive stock of spares and aim to provide support throughout the product’s expected life. Spares can be purchased from approved stockists or merchants (locations on request) or direct from Customer Services. Spares direct will normally be despatched within two working days. Payment can be made by Visa or MasterCard at the time of ordering. Should payment by cheque be preferred, a pro-forma invoice will be sent. All spares are guaranteed for 12 months from date of purchase. Spares that have been supplied directly form us can be returned within one month from date of purchase, providing that they are in good order and the packaging is unopened. Note! Returned spares will be subject to a 15% restocking charge and authorisation must be obtained before return. Please contact our Customer Services Team. Note! In the interests of safety, spares requiring exposure to mains voltages can only be sent to competent persons.
Service
Our Service Force is available to provide a quality service at a reasonable cost. Yo u will have the assurance of a Mira trained engineer/agent, genuine Mira spare parts and a 12 month guarantee on the repair. Payment should be made directly to the engineer/agent using Visa, MasterCard or a cheque supported by a banker’s card.
To Contact Us
England, Scotland, Wales and Northern Ireland Mira Showers Customer Services
Te lephone: 0870 241 0888, Mon to Fri 8:00 am - 5:30 pm Sat 8:30 am - 3:30 pm E-mail: technical@mirashowers.com Fax: 01242 282595 By Post: Cromwell Road, Cheltenham, Gloucestershire, GL52 5EP
Eire Modern Plant Ltd (Dublin)
Te lephone: 01 459 1344, Mon to Fri 9:00 am - 5:00 pm E-mail: sales@modernplant.ie Fax: Dublin 01 459 2329 Post: Otter House, Naas Road, Clondalkin, Dublin 22
Modern Plant (Cork)
Te lephone: 021 496 8755, Mon to Fri 9:00 am - 5:00 pm E-mail: cork@modernplant.ie Fax: 021 496 8607 Post: Tramore Road, Cork
Mira is a registered trade mark of
Kohler Mira Limited.
The company reserves the right to alter
product specifi cations without notice.
www.mirashowers.com
5
+
!
3
1084102-W2-A (B94E) (1663) © Kohler Mira Limited, October 2007
Loading...