Minuteman RPM20161VN Specsheet

Page 1
RPM Series Remote Power Managers
RPM1581HVN / RPM20161VN / RPM2082HVI / RPM20162VI
Save Time & Cut Costs with RPM
The Minuteman RPM® (Remote Power Manager) family is the ultimate power nerve center for controlling multiple network devices and services. With a single Minuteman RPM, you can individually control AC power for up to sixteen connected devices such as servers, switches, routers, modems, and telephone systems.
RPM Features
Minuteman's newest additions to the RPM family of products offer many new features, along with the convenience afforded by the original lineup.
• Allows rebooting from any internet-enabled device via a secure connection
• Allows scheduling of tasks
• Offers password-protected security levels
Congure and control RPM units worldwide through most standard web browsers using a single network IP address
• Accommodates RPM technology with most network and security protocols
• Manage devices from anywhere in the world
• 10 foot power cord for versatile installations
• 15 & 20-amp capacities, 120 and 208VAC
• True RMS (Root Mean Square) load meter and LCD display
• 1U / 0U convertible, and 0U vertical-only models
• SNMP & DNS Support
Model Nomenclature:
RPM 15 8 1 HV N
Input Circuit Breaker
(Amps)
Receptacle
Quantity
(1)20/(2)08
VAC
Install
Format
(N)EMA / (I)EC
Receptacles
Control from Anywhere
Minuteman RPMs offer a secure connection which is accessible from any device with a standard internet browser, including desktop and laptop PCs, smartphones, and tablets.
From these devices, users can control and congure all
aspects of the device, including:
• LAN Connection: The RPM is an IP-based PDU that connects to your network via CAT5 cable
• Control Individual Outlets: Power on/off, reboot, and monitor up to 16 individual devices from a single IP address
• Scheduled Management Actions: save power with automatic shutdown and startup of devices over week­ends or holidays
Notications via SNMP, Email, or SMS: To keep you informed of events such as a server shutdown, the
RPM can submit its notications via network broadcast,
email, or SMS text message
• Monitor Current Draw: View combined current draw
on the RPM in real time, and congure warning and
overload thresholds
RPM20161VN
Like Being Everywhere, All the Time
The Minuteman RPM is the ideal solution for network administrators who manage one or more remote locations. Once connected to the network, you can easily control it from virtually anywhere using a standard web browser and your password. With a simple click, power up, down, or reboot any of up to 16 devices connected to the RPM. Au­tomatic reboots of locked devices are also possible via ping actions (see pgs. 2 & 3 for more details).
Access from your smarphone! See pgs.
2 & 3 for details
1455 LeMay Drive | Carrollton, Texas 75007 | 972.446.7363 | 800.238.7272
www.minutemanups.com | www.sizemyups.com | www.sizemypdu.com
RPM20162VI
RPM2082HVI
RPM1581HVN
Para Systems, Inc. | Minuteman Power Technologies
Page 2
Monitoring & Management Overview
Minuteman RPM products include an easy-to-use IP-based web interface for controlling and monitoring connected devices.
Administrators can access this utility via the LAN or from beyond via a secure connection to the native web Server
within the unit. Full monitoring, control, and conguration is
possible from any device with an internet browser, enabling control from literally anywhere in the world.
Take a tour of the interface on these two pages, and visit http://www.minutemanups.com/rpm to learn more.
RPM Benefits
Utilizing Minuteman's remote power manager products
allows technicians and administrators to:
• Save Time: Reboot remote devices in seconds, not minutes or hours
Increase Productivity: Eliminate help desk calls & lost
time when a device locks up: RPM noties & provides
automatic reboot capabilities
• Cut Costs: Eliminate service calls to remote locations by managing devices from your computer or smart­phone
Monitor RPM Information in Real Time
The Information tabs provide real time status of the RPM, including real time combined current draw (g. 1), user congurable warning and overload thresholds. Network information, including MAC address and RPM name settings, are also displayed on the System tab (g. 2),
allowing quick reference for identication when multiple RPMs are in use.
g. 1: Main Interface
g. 2: System tab
Control Connected Devices
Within the four control tabs, users can control
individual outlets via On/Off/Reboot (OFF/
ON) commands (g. 4). Users can also group outlets to allow multiple devices which work
together to be controlled simultaneously.
g. 4: Outlet tab
The user can also schedule power on, off,
or reboots at specic times/dates (one time or
recurring) for indivduals or groups of receptacles (g. 5). With this feature, administrators can save power by scheduling network downtime on weekends and holidays.
Securely access the RPM control interface from anywhere with the easy-to-use web-based control panel.
PCs/Laptops
• Smartphones
(all brands)
• Tablets
(all brands)
2
Minuteman® RPM Series Remote Power Manager
g. 5: Schedule tab
g. 6: Ping Action tab
The Ping Action tab (g. 6) enables the
RPM to "ping" a device connected to a specic
receptacle. If unanswered, the device can be rebooted to unlock it, preventing downtime.
Page 3
Configuring the RPM
A wide array of settings are accessible in the conguration tabs,
allowing users to adapt individual or groups of outlets to the needs of
individual devices. These changes may be made on the y, providing
unparalleled versatility and adaptability.
g. 7: RPM tab
g. 8: Mail tab
Users can assign a descriptive name to each receptacle to prevent confusion, and set a startup and power-down delay sequencing when necessary (g. 7). Users can also set up to three email addresses (g. 8)
to receive notication messages when any event takes place, including
warning and overload thresholds, power events, and lockups.
Additional conguration parameters include:
Secure Connection with SSL
Minuteman's RPM products feature SSL security capability. When the SSL function is enabled, all communication with the device is done via HTTPs secure IP address, ensuring a safe and secure connection.
The user is able to congure custom user ID
and password for SSL access.
Threshold Tab
Congure warning and
overload levels for amper­age load on the RPM unit;
notications sent via email
or SNMP trap
Network Tab
Settings for IP-address selection; DHCP enabled by default, static IP can
be dened if desired
SNMP Tab
Congure the RPM to
send Simple Network Management Protocol traps to notify when an event occurs
Enterprise RPM Management Utility Included
Minuteman RPMs include a free software utility that offers a consolidated
location to monitor the status and review conguration information for all
RPM devices across a network. Features include:
• Function Menu: Provides device information as well as data/event logging results for individual RPM units
RPM List: Network tree showing all individual or group RPM on the LAN
RPM Information: An itemized list of status and device information for all RPM units on LAN
Time Tab
Users can set RPM sys­tem time manually, or to update automatically via
a dened network time
server
View the full line of RPM products at www.minutemanups.com/rpm
3
Page 4
Minuteman® RPM Series Remote Power Manager Specifications
Model RPM1581HVN RPM20161VN RPM2082HVI RPM20162VI
Installation Format 1U / 0U 0U 1U / 0U 0U Dimensions 1.73" x 3.54" x 17.01" 2.2" x 1.73" x 49.02" 1.73" x 3.54" x 17.01" 2.2" x 1.73" x 49.02" Operating Temperature Range 0° - 50°C Operating Humidity Range 0 - 90% Input Power Cord (Type) IEC320 C19 to 5-15P IEC320 C19 to 5-20P IEC320 C19 to 6-20P Power Cord Length 10 feet Receptacle Quantity 8 16 8 16
Receptacle Type 5-15/20R 5-15/20R IEC320 C13
Input Circuit Breaker 15A 20A 15A 20A Maximum Capacity 12A 16A 12A 16A True RMS Meter or Digital True RMS LCD Display Yes Individual Outlet Monitoring / Control Yes
Grouped Outlet Monitoring / Control Yes
Supports Data Encryption SSL / HTTPs Power On/Off Sequencing Yes Scheduled On/Off/Cycling Yes Remote Power/Status
Monitoring Temp/Humidity Monitoring Option No Ping Response Capability Ye s Event Alert Types Email / Trap / Audible Environmental Monitoring Response No Multiple Level Account Setup No Congurable Alarm Thresholds 1 (Set for entire RPM) RADIUS Login Support No SYSLOG Support Yes (w/SW Utility) Inactive User Logoff No
DNS Support Yes
Batch Firmware Upgrades (Over LAN) No
Safety Certication UL60950-1
RoHS Compliant Yes
Yes
(14) IEC320 C13 /
(2) IEC320 C19
RPM Series Sample Installation RPM Series Components
RPM2082HVI
1
Router
Server 1
Pure Sine Wave Power from UPS
Minuteman Endeavor Series UPS
Utility Power
© Copyright 2012, Para Systems, Inc. Product specications are subject to change without notice.
Minuteman and Minuteman Platinum Protection Plan are registered trademarks of Para Systems, Inc.
Server 2
Control Via Web Browser
on PC, tablet, or smartphone
1. Circuit Breaker
2. AC Outlets
3 Outlet Power Status Indicators
4. SSL & DHCP Status Indicators
Para Systems, Inc. | Minuteman Power Technologies
1455 LeMay Drive | Carrollton, Texas 75007 | 972.446.7363 | 800.238.7272
www.minutemanups.com | www.sizemyups.com | www.sizemypdu.com
2
3
4
5 6
8
5. True RMS Load Status Meter
6. Function Switch
7. CAT5 Ethernet Connection
8. IEC320 Input Power Receptacle
PN-34000465 - 7-12
7
Loading...