Minuteman ED8200RTXL, ED8000RTXL5TFMB, ED8000RTXL, ED6200RTXLMB, ED6200RTXL Specsheet

...
Protection For Mission-critical Applications
The Minuteman® Endeavor™ 5-10kVA Series UPS combines transient
free pure sine wave output, extended runtime capability, and redundant or
parallel congurations for critical applications. A front panel LCD display provides visual notication of the UPS status, including AC input status, battery status, and UPS fault indication.
Endeavor 5-10kVA Upgraded Features
• User-friendly LCD Display
control of the unit
Easy to order model numbers
Bundled systems suitable for most applications
Endeavor reliability, added options
Expands Endeavor product family to 10kVA in a rack/tower format; allows paralleled systems up to 20kVA in capacity
Output receptacle congurations on some models
All dual-voltage output models will have standard receptacle congurations
Versatile input: Standard
5/6kVA models include an L6-30P power cord standard
Ultra-Configurable Value for Large Systems
The Endeavor Series is available in a multitude of conguration options to ensure a proper system is available for most applications. In addition to multiple voltage congurations for each capacity level (ED(X)200RTXL models feature 208V in/out, ED(X)000RTXL models include 208V in and 120/208VAC out), additional accessories are available to further tailor the Endeavor to individual needs.
Available accessories include isolation stepdown transformers, external
maintenance bypass switches (MTBS), and even combinations of these options to help users tailor the Endeavor to the needs of their specic system.
Parallel Installations Made Easy
Endeavor Series units can be paralleled for either capacity or redundancy, thanks to innovative internal hardware that detects load and
automatically switches as needed.
With a single part number, the Endeavor can provide the base unit capacity (5, 6, 8, or 10kVA) as an N+1 redundant conguration, or automatically switch to parallel for capacity after surpassing 50% load. This occurs within the unit automat­ically, no action is required by the user.
Endeavor 5-10kVA Rackmount Online UPS
ED5200RTXL / ED6200RTXL / ED8200RTXL / ED10200RTXL ED5000RTXL / ED6000RTXL / ED8000RTXL / ED10000RTXL
Capacity
Small
Applications
Real-time LCD status display
See power and unit status, estimated runtime, and more in real time
Parallelable to 20kVA (208V-only models)
Scalable capacity to grow with the customer’s loads
240V input/output conguration optional
Units can be factory congured for 240V power for an additional charge
Automatic internal bypass
The UPS will sound an alarm and go to bypass mode when an
internal fault, either hardware or battery, is detected
Independent Battery Bypass (IBB)
The unit will provide a constant 120/208V output, even with dead or defective batteries when utility power is present
Smart fan control
Variable speed fan control maximizes the cooling of the UPS while maintaining optimum efciency
Cold start function
Start UPS even without utility power
Simultaneous communication options
RS-232 and optional SNMP communications provide greater exibility in the management and monitoring of the UPS system
3-year standard product warranty
Lower cost of ownership and greater reliability
5-year extended warranty options available
Platinum Protection Plan
Insures properly connected equipment up to $200,000
ENERGY STAR Certied
To maximize energy savings, all models meet EPA's ENERGY STAR efciency standards
RoHS 2 compliant
European Union reduction of hazardous substances in electrical equipment: 2011/65/EU
Midsize
Enterprise level
VoIP SystemsNetwork/Server IP/Analog Phone & Security
®
1
Features & User Benefits
True double-conversion online technology:
Maximum protection for critical equipment
Digital Signal Processor (DSP) design
Higher reliability through reduced number of UPS
components
Higher power factor (0.9pf)
Increases the real power capacity of each individual model
120/208V output models with standard receptacles
Flexibility to support multiple voltages used on connected loads
Endeavor 5/6kVA 2U control unit, battery pack, and transformer
(6U total height)
1
U.S. 48 & Canada only
Para Systems, Inc. | Minuteman Power Technologies
1455 LeMay Drive | Carrollton, Texas 75007 | 972.446.7363 | 800.238.7272
www.minutemanups.com | www.sizemyups.com
Electrical Characteristics
Digital Signal Processor
Reduced number of components in
the UPS also reduces the potential for defects or malfunctions
Digital Signal Processor (DSP)
combines many components into
a single processor, increasing the reliability of the UPS and reducing any
downtime potential
Helps ensure stable, quality power
and long life span
High Output Power Factor
All models feature an output power
factor of 0.9 which increases the Watt capacity of the units
Larger capacities in a smaller UPS VA rating can reduce the overall cost
of the UPS solution for a specic load requirement
Output T.H.D.
Endeavor units maintain an output AC signal within 2% of a true sine
wave pattern (Total Harmonic Distortion)
Prevents equipment damage from internal heat build up on sensitive
connected equipment
Overload Capacity
Sudden spikes can occur when supporting IT infrastructure, industrial
equipment, security installations or any electrically-driven load
Endeavor UPSs are designed to support such situations with the ability
to absorb up to 150% of its rated load for up to 30 seconds
Allows the UPS to be sized for maximum capacity without worry of
overload and shutdown, providing cost-savings
Independent Battery Bypass
An independent battery circuit allows the Endeavor UPS to operate in
Normal Mode, even with weak, dead, or defective batteries
Endeavor UPSs monitor internal battery status at regular intervals; if the
UPS detects weak or bad batteries, it will engage an audio alarm and also any precongured electronic notications
Normal AC output will be maintained as long as utility power is supplied
within the UPS’ nominal input range
The UPS will still provide a constant 120 or 208V output signal while
allowing time to replace batteries without having to shut down connected
equipment
Optional 240V Output
Endeavor units can be factory congured for use with 240V input and
output applications for an additional charge
Include ED-240VAC with Endeavor 5-10 order for 240V conguration
For more information about this option, please contact your Minuteman
representative
Communications
Bundled with SentryHD™ software
Minuteman SentryHD auto-shutdown and
monitoring software is included - see below for
more details
SNMP-compatible (with SNMP-NET and SNMP-NV6 cards)
All models include a standard internal communication slot compatible
with all current Minuteman SNMP cards
Adding an SNMP-NET or SNMP-NV6 card allows remote management
and control over any IP-based network
The Option card slot and serial communications port can be operated
simultaneously, allowing SNMP to be used in conjunction with Minuteman SentryHD software
Using SNMP and SentryHD, users can enable high efciency Economy
Mode for increased energy savings
Battery Characteristics
Extended Runtime Capability
All models come bundled with a battery pack module
For protection through extended blackouts, the Endeavor Series can
also utilize connections built into each battery pack to connect multiple
units, providing virtually unlimited runtime capabilities
Models ED5(X)00 ED6(X)00 ED8(X)00 ED10(X)00
External Battery Pack BP192RTXL BP240RTXL
Rack Height 2U 3U
External Battery Pack Chargers
Optional 2U external battery pack charger lessens recharge times for
applications requiring extended or extremely long runtimes
While built-in chargers provide ample capacity to support multiple
battery packs, external chargers can shorten the recharge time of the
connected battery packs exponentially
Critical for installation environments that experience frequent outages or
long periodic outages
Battery Technology
All Endeavor Series battery packs use valve-regulated lead-acid
batteries (VRLA); safe for all freight transport
Hot-Swappable Batteries
Batteries in the Endeavor Series UPS can be replaced without the need
to shut down the unit (requires removal from rack)
Connected loads are protected from voltage anomalies and spikes and
surges while the batteries are being replaced
New LCD Status Display
Endeavor Series UPS products now feature
an informative LCD display. This display offers real-time feedback on the following areas:
Input / Output Voltage and Frequency
Display to monitor the status of your utility
power
UPS Battery Mode/Status Icons which
eliminates guesswork with a straight­forward display of the UPS status
Load Capacity Indicator displays how much of a connected load is
being placed on the unit
Numeric Estimated Runtime Display which is based on the
connected load to indicate how much backup time remains during a
blackout
Minuteman Endeavor 5-10kVA Series UPS2
SentryHD™ Software
Minuteman’s SentryHD™ UPS
monitoring and control software comes
included with each Endeavor Series UPS
unit. Users can monitor and control the
UPS products on a connected network
from one application session. Features
include:
Support for 32/64-bit operating
systems
Batch conguration capable
SNMP (v1, v2c, v3) trap support
Supports scheduled UPS shutdown, restart and battery testing
User congurable e-mail and SMS alarm notices
Supports both RS-232 and SNMP communication protocols
A Complete System - One Part Number
ED-MTBSUPS & BP 1 UPS & BP 2
The complete listing of available conguration bundles is listed in the charts at right. Each of these bundles provides a complete system including the equipment noted in the description, making specication, ordering, and installation a simple, straightforward process. System components include:
UPS Control Unit (CU)
System control unit featuring an LCD status display,
connections for communications, battery packs, and
other modules
2U (5/6kVA) or 3U (8/10kVA) rack height module
Battery Pack (BP)
BP192RTXL (5/6kVA) or BP240RTXL (8/10kVA)
external battery pack
Each bundle includes single battery pack standard
Multiple battery packs can be connected via daisy-chain capability for extreme
runtime needs
External Maintenance Bypass Switch (MTBS)
The MTBS is a separate module from the UPS that
allows the unit to be taken ofine without removing
connected equipment from utility power
Included as a bundle on “-MB” models or sold separately as an accessory; mountable
to the rack (3U total height), to the UPS control unit, or to the wall
If the UPS experiences an internal fault (battery or hardware-related), the user can
bypass the UPS, providing utility power directly to connected equipment while the
UPS is repaired
Efciently upgrade or expand connected equipment without having to bring down
current infrastructure
Isolation Stepdown Transformer (XFR, 5TF)
Independent module which can “step down” the
208V input voltage to 120VAC output voltage
Available in full UPS capacity (XFR) or 5kVA
capacity (5TF)
All transformer modules come with various NEMA output receptacle congurations for
greater exibility on installation requirements
Isolation hardware ideal for sensitive applications including audio/visual equipment,
scientic, and other critical devices
208 In / 208 Out (240V Optional - see page 2)
Input
Model No.
ED5200RTXL 208 208 4U CU, BP
ED6200RTXL 208 208 4U CU, BP
ED8200RTXL 208 208 6U CU, BP
ED10200RTXL 208 208 6U CU, BP
w/ Maintenance Bypass Switch (add 3U if rack mounting MTBS)
ED5200RTXLMB 208 208 4U CU, BP, MTBS
ED6200RTXLMB 208 208 4U CU, BP, MTBS
ED8200RTXLMB 208 208 6U CU, BP, MTBS
ED10200RTXLMB 208 208 6U CU, BP, MTBS
Voltage
Output
Voltage
Rack
Height
Bundle Contents (see desc. at left)
208 In / 120/208 Out (240V Optional - see page 2)
Input
Model No.
ED5000RTXL 208 120 / 208 6U CU, BP, XFR
ED6000RTXL 208 120 / 208 6U CU, BP, XFR
ED8000RTXL 208 120 / 208 9U CU, BP, XFR
ED10000RTXL 208 120 / 208 9U CU, BP, XFR
w/ Maintenance Bypass Switch (add 3U if rack mounting MTBS)
ED5000RTXLMB 208 120 / 208 6U CU, BP, XFR, MTBS
ED6000RTXLMB 208 120 / 208 6U CU, BP, XFR, MTBS
ED8000RTXLMB 208 120 / 208 9U CU, BP, XFR, MTBS
ED10000RTXLMB 208 120 / 208 9U CU, BP, XFR, MTBS
w/ 5kVA Max Transformer (5TF) & MTBS (add 3U if rack mounting MTBS)
ED8000RTXL5TF 208 120 / 208 8U CU, BP, 5TF
ED10000RTXL5TF
ED8000RTXL5TFMB
ED10000RTXL5TFMB
Voltage
Output
Voltage
208 120 / 208 8U CU, BP, 5TF
208 120 / 208 8U CU, BP, 5TF, MTBS
208 120 / 208 8U CU, BP, 5TF, MTBS
Rack
Height
Bundle Contents (see desc. at left)
Installation Versatility
All models can be installed as either
rackmount or stand-alone tower
A rail kit (below) for rackmount installa-
tions and foot brackets for stand-alone installations is also included standard
Tower mount feet expand to allow
additional modules (both transformers and battery modules) as needed for growth
Scalability Made Easy
Easily expand as needed - purchase or expand 2 208V units for
paralleled operation
System will automatically: (a) Provide double the base unit capacity
if connected load is more than 50% total capacity (b) Provide N+1 redundancy if connected load is less than 50% total capacity
Parallel congurations can be easily ordered using a single part
number; no extra hardware, cables, or other accessories are required
Parallel
VA/ Watts 10000/9000 12000/10800 16000/14400 20000/18000
MTBS
Weight 368 369 491 492
ED10000RTXLP ED12000RTXLP ED16000RTXLP ED20000RTXLP
5/6kVA 120/208V Output Rear View
All Endeavor bundles include a control unit (top), and battery pack (middle). All 120V output capable systems (ED(X)000RTXL) also include a transformer (bottom).
1. UPS Control Unit
2. SNMP Option Slot
3. Parallel RS-232 Connections
4. Cooling Fans
5. External Battery Connection
6. Input Circuit Breaker
7. Input/Output Connections
8. External Battery Pack
9. Battery Pack (DC) Circuit Breaker
10. Control Unit/BP Connections
11. Optional 120V Transformer
12. 120V NEMA 5-15/20R Output Receptacles
13. 208V L6-20R Output Receptacle
14. 208V L6-30R Output Receptacle
15. Input Voltage Selection (208/240V)
1
2 3 4
8
9
11
12
Connect Load
Connect Utility
UPS Control
10
13 14
5
UPS Input/Output
6
7
15
View the full line of Endeavor 5-10kVA products at www.minutemanups.com/endeavor510 3
Minuteman® Endeavor 5-10kVA Online Rackmount UPS Specifications
Model Number - 208V (240V Opt.) Output (120V Capable)
General
Maximum Power Capacity
Topology Double Conversion Online, True Sine Wave
Input Plug Type
Output Outlet Type
Number of Phases Single (1ф 2W + G)
Input
Nominal Voltage 208 (240VAC factory congurable option)
Acceptable Input Voltage 0 - 300VAC
Voltage Range 156 - 280VAC 180 - 280VAC
Power Factor Correction ≥99% at Full Load
Frequency Limits 40 to 70Hz at Full Load
Low Voltage Transfer Point 156/180 resets to Utility Power at 166/190VAC or higher
High Voltage Transfer Point 280VAC resets to Utility Power at 270VAC or lower
Input Protection Resettable Circuit Breaker
Voltage Range 208VAC: 204 - 212VAC (240VAC: 235 - 245VAC)
Voltage Regulation Nominal +/-2%
Frequency Range 50/60Hz, auto selecting, +/-00.1Hz (unless synchronized to utility)
Output: Online
Efciency (Online Mode) >90% (Full Load)
Waveform Type True Sine Wave
Nominal Voltage Default: 208VAC, User-selectable:220/230/240VAC
Voltage Regulation Nominal +/-2% (until Low Battery warning)
Frequency 50/60Hz, +/-0.1Hz
Output: Battery
Voltage T.H.D. ≤2% (Linear Load)
Dynamic Response +/-5% @ 100% Load change in 30ms
Transfer Time 0 ms
Slew Rate ≤1Hz / second
Crest Factor 3 : 1 2.7 : 1
Overload Capacity ≥106% - ≤110% for 10 minutes / ≥111% - ≤125% for 5 minutes / ≥126% - ≤150% for 30 seconds
System Voltage 192VDC 240VDC
Runtime: Full Load (minutes) 4 3 5 4
Battery
Runtime: Half Load (minutes) 12 11 13 12
Surge Energy Rating 1050J
Surge Current Capability 6500 Amps total
Surge Response Time 1.2µs normal mode; <50µs common mode
Surge voltage let-through (as a percentage of an applied ANSI C62.41 Cat. B +/-4kV)
Surge Protection
Noise Filter normal and common mode EMI/RFI suppression
Audible Noise at 1m (3 ft.) <60dBA
Operating Temperature (max) 0 to +40°C (+32 to +104°F)
Storage Temperature -15 to +50°C (+5 to +122°F)
Operating/Storage Humidity 0 ~ 95% Non-Condensing
Operating Elevation 0 to 2,000m (0 to +6,562 ft.)
Environmental
Storage Elevation 0 to 15,000m (0 to +49,213 ft.)
Size - Net - LxWxH
Physical
Weight - Net
Safety and Approvals cTUVus (Conforms to UL1778 4th Edition & CSA 22.2 no. 107.3-05), RoHS 2 , ENERGY STAR
EMC Verication FCC Class B, CE Certied
Regulatory
Warranty • Platinum Protection Three-years parts, labor, and battery (non-prorated); 5-year extended plans available • $200,000
ED5200RTXL
(ED5000RTXL)
5000VA / 4500W
(4556VA / 4100W)
Hardwire / L6-30P/pigtail cord included
(Hardwire / L6-30P/pigtail cord included)
(6 - NEMA 5-15/20R, 1 - L6-20R, 1-L6-30R)
26.0 x 17.3 x 7.0" / 660.0 x 440.0 x 177.5 mm
(26.2" x 17.3" x 10.5" / 665.0 x 440.0 x 266.0 mm)
Hardwire Only
115.8 lbs. / 52.5 Kgs.
(198.5 lbs. / 88.0 Kgs.)
ED6200RTXL
(ED6000RTXL)
6000VA / 5400W
(5556VA / 5000W)
ED8200RTXL
(ED8000RTXL)
8000VA / 7200W
(6889VA / 6200W)
Hardwire Only
(Hardwire Only)
Hardwire Only
(8 - NEMA 5-15/20R, 1 - L6-20R, 1 - L6-30R)
<10%
24.6 x 17.3 x 10.28" / 625 x 440 x 261.2 mm
(25.9" x 17.3" x 15.4" / 659.0 x 440.0 x 391.8 mm)
181.0 lbs. / 82.1 Kgs.
(339.7 lbs. / 154.1 Kgs.)
ED10200RTXL
(ED10000RTXL)
10000VA / 9000W (8889VA / 8000W)
© Copyright 2014, Para Systems, Inc. Product specications are subject to change without notice. Minuteman and Minuteman Platinum Protection Plan are registered trademarks; SentryHD is a trademark of Para Systems, Inc.
www.minutemanups.com | www.sizemyups.com
PN-34000487 - 08-14