![](/html/c7/c722/c722705a0b44cf471d95a33fab9a1642843f96947dfa9b32566421265e3b988d/bg1.png)
Protection For Mission-critical Applications
The Minuteman® Endeavor™ 5-10kVA Series UPS combines transient
free pure sine wave output, extended runtime capability, and redundant or
parallel congurations for critical applications. A front panel LCD display
provides visual notication of the UPS status, including AC input status,
battery status, and UPS fault indication.
Endeavor 5-10kVA Upgraded Features
• User-friendly LCD Display
Minuteman's familiar LCD interface provides real-time status and
control of the unit
• Easy to order model numbers
Bundled systems suitable for most applications
• Endeavor reliability, added options
Expands Endeavor product family to 10kVA in a rack/tower format;
allows paralleled systems up to 20kVA in capacity
• Output receptacle congurations on some models
All dual-voltage output models will have standard receptacle
congurations
• Versatile input: Standard
5/6kVA models include an L6-30P power cord standard
Ultra-Configurable Value for Large Systems
The Endeavor Series is available in a multitude of conguration options
to ensure a proper system is available for most applications. In addition
to multiple voltage congurations for each capacity level (ED(X)200RTXL
models feature 208V in/out, ED(X)000RTXL models include 208V in and
120/208VAC out), additional accessories are available to further tailor the
Endeavor to individual needs.
Available accessories include isolation stepdown transformers, external
maintenance bypass switches (MTBS), and even combinations of these
options to help users tailor the Endeavor to the needs of their specic
system.
Parallel Installations Made Easy
Endeavor Series units can be paralleled for either capacity or
redundancy, thanks to innovative internal hardware that detects load and
automatically switches as needed.
With a single part number, the Endeavor can provide the
base unit capacity (5, 6, 8, or 10kVA) as an N+1 redundant
conguration, or automatically switch to parallel for capacity
after surpassing 50% load. This occurs within the unit automatically, no action is required by the user.
Endeavor 5-10kVA Rackmount Online UPS
ED5200RTXL / ED6200RTXL / ED8200RTXL / ED10200RTXL
ED5000RTXL / ED6000RTXL / ED8000RTXL / ED10000RTXL
Capacity
Small
Applications
• Real-time LCD status display
See power and unit status, estimated runtime, and more in real time
• Parallelable to 20kVA (208V-only models)
Scalable capacity to grow with the customer’s loads
• 240V input/output conguration optional
Units can be factory congured for 240V power for an additional
charge
• Automatic internal bypass
The UPS will sound an alarm and go to bypass mode when an
internal fault, either hardware or battery, is detected
• Independent Battery Bypass (IBB)
The unit will provide a constant 120/208V output, even with dead or
defective batteries when utility power is present
• Smart fan control
Variable speed fan control maximizes the cooling of the UPS while
maintaining optimum efciency
• Cold start function
Start UPS even without utility power
• Simultaneous communication options
RS-232 and optional SNMP communications provide greater
exibility in the management and monitoring of the UPS system
• 3-year standard product warranty
Lower cost of ownership and greater reliability
• 5-year extended warranty options available
• Platinum Protection Plan
Insures properly connected equipment up to $200,000
• ENERGY STAR Certied
To maximize energy savings, all models meet EPA's
ENERGY STAR efciency standards
• RoHS 2 compliant
European Union reduction of hazardous substances in electrical
equipment: 2011/65/EU
Midsize
Enterprise level
VoIP SystemsNetwork/Server IP/Analog Phone & Security
®
1
Features & User Benefits
• True double-conversion online technology:
Maximum protection for critical equipment
• Digital Signal Processor (DSP) design
Higher reliability through reduced number of UPS
components
• Higher power factor (0.9pf)
Increases the real power capacity of each individual model
• 120/208V output models with standard receptacles
Flexibility to support multiple voltages used on connected loads
Endeavor 5/6kVA 2U control unit, battery pack, and transformer
(6U total height)
1
U.S. 48 & Canada only
Para Systems, Inc. | Minuteman Power Technologies
1455 LeMay Drive | Carrollton, Texas 75007 | 972.446.7363 | 800.238.7272
www.minutemanups.com | www.sizemyups.com
![](/html/c7/c722/c722705a0b44cf471d95a33fab9a1642843f96947dfa9b32566421265e3b988d/bg2.png)
Electrical Characteristics
Digital Signal Processor
• Reduced number of components in
the UPS also reduces the potential for
defects or malfunctions
• Digital Signal Processor (DSP)
combines many components into
a single processor, increasing the
reliability of the UPS and reducing any
downtime potential
• Helps ensure stable, quality power
and long life span
High Output Power Factor
• All models feature an output power
factor of 0.9 which increases the Watt capacity of the units
• Larger capacities in a smaller UPS VA rating can reduce the overall cost
of the UPS solution for a specic load requirement
Output T.H.D.
• Endeavor units maintain an output AC signal within 2% of a true sine
wave pattern (Total Harmonic Distortion)
• Prevents equipment damage from internal heat build up on sensitive
connected equipment
Overload Capacity
• Sudden spikes can occur when supporting IT infrastructure, industrial
equipment, security installations or any electrically-driven load
• Endeavor UPSs are designed to support such situations with the ability
to absorb up to 150% of its rated load for up to 30 seconds
• Allows the UPS to be sized for maximum capacity without worry of
overload and shutdown, providing cost-savings
Independent Battery Bypass
• An independent battery circuit allows the Endeavor UPS to operate in
Normal Mode, even with weak, dead, or defective batteries
• Endeavor UPSs monitor internal battery status at regular intervals; if the
UPS detects weak or bad batteries, it will engage an audio alarm and
also any precongured electronic notications
• Normal AC output will be maintained as long as utility power is supplied
within the UPS’ nominal input range
• The UPS will still provide a constant 120 or 208V output signal while
allowing time to replace batteries without having to shut down connected
equipment
Optional 240V Output
• Endeavor units can be factory congured for use with 240V input and
output applications for an additional charge
• Include ED-240VAC with Endeavor 5-10 order for 240V conguration
• For more information about this option, please contact your Minuteman
representative
Communications
Bundled with SentryHD™ software
• Minuteman SentryHD auto-shutdown and
monitoring software is included - see below for
more details
SNMP-compatible (with SNMP-NET and SNMP-NV6 cards)
• All models include a standard internal communication slot compatible
with all current Minuteman SNMP cards
• Adding an SNMP-NET or SNMP-NV6 card allows remote management
and control over any IP-based network
• The Option card slot and serial communications port can be operated
simultaneously, allowing SNMP to be used in conjunction with
Minuteman SentryHD software
• Using SNMP and SentryHD, users can enable high efciency Economy
Mode for increased energy savings
Battery Characteristics
Extended Runtime Capability
• All models come bundled with a battery pack module
• For protection through extended blackouts, the Endeavor Series can
also utilize connections built into each battery pack to connect multiple
units, providing virtually unlimited runtime capabilities
Models ED5(X)00 ED6(X)00 ED8(X)00 ED10(X)00
External Battery Pack BP192RTXL BP240RTXL
Rack Height 2U 3U
External Battery Pack Chargers
• Optional 2U external battery pack charger lessens recharge times for
applications requiring extended or extremely long runtimes
• While built-in chargers provide ample capacity to support multiple
battery packs, external chargers can shorten the recharge time of the
connected battery packs exponentially
• Critical for installation environments that experience frequent outages or
long periodic outages
Battery Technology
• All Endeavor Series battery packs use valve-regulated lead-acid
batteries (VRLA); safe for all freight transport
Hot-Swappable Batteries
• Batteries in the Endeavor Series UPS can be replaced without the need
to shut down the unit (requires removal from rack)
• Connected loads are protected from voltage anomalies and spikes and
surges while the batteries are being replaced
New LCD Status Display
Endeavor Series UPS products now feature
an informative LCD display. This display offers
real-time feedback on the following areas:
• Input / Output Voltage and Frequency
Display to monitor the status of your utility
power
• UPS Battery Mode/Status Icons which
eliminates guesswork with a straightforward display of the UPS status
• Load Capacity Indicator displays how much of a connected load is
being placed on the unit
• Numeric Estimated Runtime Display which is based on the
connected load to indicate how much backup time remains during a
blackout
Minuteman Endeavor 5-10kVA Series UPS2
SentryHD™ Software
Minuteman’s SentryHD™ UPS
monitoring and control software comes
included with each Endeavor Series UPS
unit. Users can monitor and control the
UPS products on a connected network
from one application session. Features
include:
• Support for 32/64-bit operating
systems
• Batch conguration capable
• SNMP (v1, v2c, v3) trap support
• Supports scheduled UPS shutdown, restart and battery testing
• User congurable e-mail and SMS alarm notices
• Supports both RS-232 and SNMP communication protocols