Minuteman ED6200RMN1, ED12000RM Specsheet

Endeavor
®
6kVA Rackmount/Tower UPS Series
Double Conversion On-line True Sine Wave
Uninterruptible Power Supply
ED6000RMXFMR - Transformer Module
EDBP6000RM - Battery Pack Module
MinUteMAn® 6kVA on-line rAckMoUnt/tower UPS.
Simple parallel installat i o n s (n o extra PCB
required)
Full digital signal processor
Easy-to-set user personalization
Intelligent self diagnosis
Smart fan control
Emergency Power Off (EPO) function
True double conversion on-line technology
High input Power Factor and low voltage THD
Energy efcient UPS
LCD/LED panel
2X customer options slots
Smart ECO
i-Batt (automatically manages end of discharge
voltage according to load capacity)
Cold start function
Communication capability
Remotely test the major operating functions
of UPS
Communicate via SNMP/Web card
Access UPS via the Internet
PPlicAtionS
A
VoIP
Data centers
Server racks
Large network switches
Total rack tower support
Large PBX systems
6kVA on-line UPS FeAtUreS
True on-line architecture supplies critical device
with transient-free pure sine wave AC power
LCD/LED front panel displays status of UPS
Switches to bypass automatically in case of
overloading at 150%
Maintenance free sealed-type battery minimizes
after-sales service
Intelligent, temperature-controlled
Can be congured as tower or rackmount
oPtionS
Maintenance bypass
Galvanic isolated transformer
Para Systems, Inc. • 800.238.7272• 1455 LeMay Drive • Carrollton, Texas 75007 USA
www.minutemanups.com•www.sizemyups.com • www.sizemypdu.com • www.comparemyups.com
Option
Card Slot 2
Option
Card Slot 1
Utility Input
Breaker
Cooling
Fans
RS-232
Connector
Utility Input
Connector
UPS
Output
Connector
Terminal Resistor
for Parallel
Function &
CAN Bus
Connection
for Parallel System
UPS
Output
208V
Utility Input
Transformer
Output
120V
Uninterruptible Power Supply
Transformer for 120V System
Battery
Module
DC
Breaker
UPS
Input
Maintenance
Bypass
Emergency
Power Off
Maintenance
Bypass
Connection
External
Battery
Connectors
Additional Battery Pack Connection
120V 208V 240V
120V 208V 240V
endeAVor 6kVA trUe on-line rAckMoUnt/tower UPS
P
ArAllel For cAPAcity conFigUrAtionS
This conguration uses mirrored Endeavor 6kVA
rackmount UPS system to achieve higher than 6kVA loads.
Currently, parallel capacity congurations can be used
to accommodate output loads of 12, 18, and 24kVA for 208V/240V systems.
Parallel for Capacity Conguration Table
Model ED12000RM ED18000RM ED24000RM
Input 12kVA
208V/240V
18kVA
208V/240V
24kVA
208V/240V
MAin control ModUle - ed6200rM
The Main Control module takes only 2U in rack height and provides 208/240V input and output. Input is hardwired to the unit. The main control module has a LCD/LED display. Each control module must have at least one battery back (EDBP6000RM). Parallel functions are available for up to 208V 24kVA. N+1 full-redundancy function is available up to 18kVA for 208/240V applications and 6kVA for 120V applications. Optional receptacle boxes are available for 6kVA units.
trAnSForMer ModUle - ed6000rMXFMr
The transformer module steps down the 208/240V input to 120/208/240V output, takes 2U in rack height, and requires a control module (ED6200RM), and Battery Pack (EDBP6000RM) to work. It has an internal bypass switch for single 6kVA installations (Not available on parallel installations). It handles 208/240V input and 120/208/240V output.
BAttery PAck ModUle - edBP6000rM
Each battery pack module (EDBP6000RM) occupies 3U in rack height and requires a control module (ED6200RM) to operate. Multiple battery packs can be daisy chained. Only one receptacle box can be attached to a battery pack module. Battery packs are charged through the main UPS.
PArAllel conFigUrAtionS
In addition to a stand-alone conguration, the Endeavor 6kVA rackmount UPS can be congured as:
Parallel for capacity (12, 18 and 24kVA output load)
Redundancy (N+1) (6, 12, and 18kVA). This allows all
of the load to be shifted to the other UPS units when
one is taken ofine. Congurations using more than two
control modules will require a parallel kit and an external maintenance bypass switch.
NOTE: 120V output from the Endeavor 6kVA rackmount UPS is
available only in a 6kVA stand-alone conguration or a Parallel
for Redundancy (N+1) 6kVA 208V/240V input and 6kVA 120V output made up of two ED6200RM control units, two EDBP6000RM battery packs and two ED6000RMXFMR transformers.
Output Load 12kVA
Watts 8400 12600 16800
Rack height 10 U 15 U 20 U
ED6200RM 2 3 4
EDBP6000RM Battery Pack
ED6-PARALLEL Parallel kit
External Maintenance
Bypass Switch
edUndAncy (n+1) conFigUrAtionS
r
208V/240V
2 3 4
1 1 1
1
ED6-MTBS21 ED6-MTBS41 ED6-MTBS4
18kVA
208V/240V
24kVA
208V/240V
This conguration is used to provide redundancy
backup. When one UPS is taken ofine, this conguration
allows the load to be redistributed to the remaining UPS units.
Redundancy (N+1) Conguration Table
Model TBA ED12000RM ED18000RM ED24000RM
Input 6kVA
Output Load 6kVA
Watts 4200 4200 8400 12600
Rack height 14 U 10 U 15 U 20 U
ED6200RM 2 2 3 4
EDBP6000RM Battery Pack
ED6000RMXFMR 2 n/a n/a n/a
ED6-PARALLEL Parallel kit
External Maintenance
Bypass Switch
208V/240V
120V
2 2 3 4
1 1 1 1
N/A 1
6kVA
208V/240V
6kVA
208V/240V
ED6-MTBS21 ED6-MTBS4
12kVA
208V/240V
12kVA
208V/240V
18kVA
208V/240V
18kVA
208V/240
1
ED6-MTBS4
oPtionAl recePtAcle BoXeS
Special
Log In/
Log Out
UPS
Off
Switch
Next
Page
UPS On Switch
&
Alarm Silence
Enter or Reconfirm
Previous Page or Setting Change
Utility
Input
Normal
LEDs
Bypass
Input
Normal
UPS in
Redundancy
Mode
UPS in
ECO
Mode
UPS Fault
or
Abnormal
Warning
V
Two receptacle boxes are available. One for 208V/240V output only (ED6-208RB) and one for both 120V and 208V/240V output (ED6-120RB).
208V-Only Receptacle Box- ED6-208RB
Receptacles: (1) L6-30R, (1) L6-20R and (4) 6-15/20R. Only
one receptacle box can be connected to a battery pack.
120V/208V Receptacle Box - ED6-120RB
Receptacles: (1) L6-30R, (1) L5-30R, (1) L5-20R and (2) 5-15/20R. Only one receptacle box can be connected to a battery pack.
endeAVor 6kVA UPS led/lcd Front PAnel diSPlAy/control
The Endeavor 6kVA UPS multi-functional LCD/LED panel will display various states of the UPS. The LED display will show the UPS working status, Utility Status and UPS Abnormal status. The LCD display will show the Input/Output voltage, frequency, load status, internal temperature, and faults.
Conguring the UPS parameters are done through the LCD.
coMMUnicAtion And SoFtwAre
The Endeavor 6kVA UPS currently uses the NetAgent SNMP card and includes software for monitoring the UPS. A new version of the ED6200RM with SentryPlus/SNMP-NET communications capability will be available in 2008.
Both versions are compatible with Minuteman’s new SentryGold Enterprise Software which permits the monitoring and control of Minuteman UPS and Power Distribution Units.
BAtterieS
The Endeavor 6kVA UPS uses a battery pack (EDBP6000RM) that contains sealed, non-spillable, maintenance free, value regulated, lead acid batteries. The UPS module does not have internal batteries. Typical recharge time for the battery pack is 8 hours from total discharge.
The battery pack contains (20) 12V 7.2Ah batteries.
Runtime at full load is 9 minutes. At half load the runtime is 23 minutes
w
hAt the FUtUre holdS . . .
Parallel Congurations: All current 6kVA products are compliant with parallel
congurations when these options are
available. In the relatively near future you will
be able to congure your Minuteman Endeavor 6kVA into a parallel conguration increasing
system capacity up to 24kVA.
Input and output will be hardwired
A parallel kit will be required. It will contain all
the required RJ-45 cabling and an instruction
manual
It is required that a maintenance bypass switch
be installed
MAintenAnce ByPASS Switch
Maintenance Bypass Switch with covers off
The maintenance bypass switch removes the requirement to
power down the UPS to perform routine maintenance, replace
batteries or to change battery conguration, The maintenance
bypass switch is usually mounted adjacent to the UPS, enabling the UPS to be isolated from the load without interrupting power to essential applications.
oPtionS
Maintenance bypass switch
Galvanic isolated transformer for 120V applications.
Parallel kit
®
Endeavor
6kVA Series On-line Rackmount UPS
Model ED6200RM
Topology
Maximum power capacity
DDouble Conversion On-Line, True Sine Wave
6000VA/4200Watts
INPUT
Voltage window 160~280VAC*
Frequency 50/60 Hz ± 5Hz autosensing
Number of phases • Surge energy rating Single (1Ø 2W +G) • 1050J
Power factor correction ≥98% at 100% Linear Load
OUTPUT
Voltage window 200/208/240VAC selectable 120V with transformer
Voltage adjustment / Voltage regulation 0%; ±1%; ±2%; ±3% /±2%
Capacity 6000VA/4200W
Rated power factor 0.7 Lagging
Wave form Sine Wave
Frequency Regulation ±0.2%(Free Running) unless synchronized to utility
Transfer time 0ms
Efciency > 87% line mode
Autonomy full/half 9 min/23 min
Voltage THD <3% at 100% Linear Load
BATTERY
Type Sealed non-spillable lead acid maintenance free 12V/7.2Ah
Quantity / Voltage / Recharge Time 20pcs / 240VDC / 8 hours to 90%
DISPLAY
Status On LED + LCD
Readings on LCD
Self-diagnostics Upon power-on, front panel setting & software control
Line mode, backup mode, ECO mode, bypass, battery low, battery bad/disconnect, overload, and transferring with interruption & UPS fault. Input voltage, input frequency, output voltage, output frequency, load percentage, battery voltage & internal temperature.
ALARMS
Audible and Visual Line failure, battery low, transfer to bypass, system fault conditions
PHYSICAL
Dimensions- WxDxH- in (mm) 17.3x3.4x26.7in (440x88x680mm) - (UPS Module)
Input/output connection / External battery connection Net weight(kg) 53.0 lb/ 24kg(UPS Module)
Battery pack net weight 120.0 lb (54.2 kg)
Battery Bank Dimensions Convertible(Rack/Tower) / 17.3x5.2x26.7in (440x132x680mm) (3U)
Isolation transformer dimensions/ Net weight 17.3x3.4x 26.7in (440x88x680mm) - (2U) / 93 lb (42 kg)
Hardwired / Plug and Play
ENVIRONMENT
Operating temperature 32°F to 104°F (0°C to 40°C)
Altitude / Humidity
Noise <50dB (at 1 meter)
0~2000m up to 104°F (40°C), 3000m up to 95°F (35°C)
/ 90% RH Maximum, Non-Condensing
COMPUTER INTERFACE
Interface type Standard RS-232 Interface
Communication slots 2nd RS-232 **, USB *** Relay Contact, SNMP/WEB Card, etc.
SAFETY CONFORMANCE
Safety and approvals UL 1778, cUL (CSA 2.2 no. 107.1), CE (EN62040-1-1)
EMC CE (EN62040-2, EN61000-3-2, EN61000-3-3), FCC Class A
Power Technologies
From Para Systems, Inc.
Para Systems, Inc./Minuteman UPS 1455 LeMay Drive, Carrollton, TX 75007 U.S.A. Phone 800.238.7272 +1 972.446.7363 Fax +1 972.446.9011
© Copyright 2008, Para Systems, Inc. Product specications are subject to change without notice. Minuteman is a registered trademark of Para Systems, Inc.
www.minutemanups.com•www.sizemyups.com • www.sizemypdu.com • www.comparemyups.com
PN-34000314 - 4-2008
Loading...