The latest in Minuteman's popular Enterprise Series, the
EnterprisePlus LCD oers users more of what has made the
series one of our best selling lines. New features include lower
cost standard runtime models, an informative LCD Display, and
additional outlets vs. previous models.
Pure Power for Sensitive Equipment
The EnterprisePlus LCD Series of UPSs oer complete
protection from all electrical problems, including spikes, surges,
sags, brownouts, and blackouts, in a versatile rack/tower
convertible format. True sine wave electrical output ensures the
best power for sensitive electronic equipment.
Upgraded Features
The EnterprisePlus LCD features many upgrades from previous
generations, including an LCD status display which shows the
following:
• Input / Output voltage and frequency
• UPS and battery mode / status
• Load capacity & Error Codes
• Estimated runtime based on connected load
In addition to the LCD display, EnterprisePlus LCD models oer
users their choice of runtime:
• Standard Runtime models (RT2U) utilize only internal
batteries and are available at a lower cost
• Extended Runtime models (RTXL2U) feature the ability to
add external battery packs for greatly increased runtimes
In accordance with Minuteman's focus on environmental
responsibility, EnterprisePlus LCD models were designed to meet
the following standards:
• RoHS 2: compliant with the updated directive as dened by
the European Economic Union for the reduction of hazardous
substances in electronic equipment: 2011/65/EU
• Energy Star®: to maximize energy savings,
select models meet EPA's Energy Star's eciency
standards
Guaranteed Reliability
• 3-year standard warranty
covering all parts and labor,
as well as non-prorated
coverage of batteries
• 5-year extended
warranty plans available
• Platinum Protection
Plan® insures properly
connected equipment up
to $100,000 (U.S. 48 &
Canada only)
All EnterprisePlus LCD models feature a 0.8 or greater power
factor, which increases the watt capacity of the units. Oering
larger capacities in smaller UPS VA sizes reduces the overall cost
of the UPS solution for a specic load requirement.
Output Voltage
All units in the EnterprisePlus LCD Series produce an electrical
signal that does not vary from nominal voltage by more than 5%.
Tightly regulating the output voltage increases the quality of power
to connected equipment adding to its life expectancy, which lowers
the total cost of ownership to users.
Total Harmonic Distortion (THD)
THD is the distortion of a normal AC electrical signal commonly
caused when UPS connected loads near the capacity of the units.
This distortion can cause internal heat to build up on sensitive
equipment not designed to allow for these altered AC signals. The
EnterprisePlus LCD UPS maintains an output AC signal, at all
times and with linear loads, within 2% of a true sine wave.
Output Receptacle Control
Three banks of receptacles (one always-on for critical devices,
two controllable via SentryHD™ and an SNMP card) allow users
to increase runtime for more critical devices during an extended
blackout.
Through the use of Minuteman’s SentryHD software or
communication with the UPS through an Ethernet connection,
users can either turn on, o, or reset each segment independently.
By reducing the connected load draw on the UPS, the runtime of
critical devices can be extended signicantly.
Communication Features
The EnterprisePlus LCD UPS provides users with the ability to
communicate with the UPS simultaneously through three separate
protocols: RS-232, USB and Ethernet. Users can directly connect
and manage the UPS from multiple stand-alone, or networked
computers. The UPS can provide detailed monitoring and
management to many various environments.
Other Features
RoHS 2 Compliancy
Para Systems developed the EnterprisePlus LCD Series to
be compliant with the updated RoHS2 Directive as dened by the
European Economic Union directive on the reduction of hazardous
substances in electronic equipment: 2011/65/EU.
Energy Star Certied
As a participant in the EPA’s Energy Star program, Para
Systems developed the EnterprisePlus LCD Series1 to meet the
highest eciency standards possible in order to maximize the
saving of user’s energy consumption.
Manual and Automatic Self-Testing
The EnterprisePlus LCD UPS is designed to proactively notify
users of any impending faults or failures with the UPS. This allows
for preemptive repair or replacement of components or batteries
preventing unexpected downtime caused by the UPS.
Dedicated EPO Port
This direct access port allows users to perform an immediate
remote shutdown of the UPS in cases of emergency or when
access to the UPS is restricted or inconvenient.
1
1500, 2000, and 3000VA models only
Rear View of E750RTXL2U
1
2
3
4
567
Rear View of E2000RTXL2U
1
2
3
13
12
13
12
1 Remote EPO Connection
2 USB Comm. Port
3 RS-232 Comm. Port
4 Output Voltage Dipswitch
5 Network/Phone Surge Protection
6 External Battery Connection
7 SNMP Option Slot
8 L5-20R 20 Amp Locking Output
9 Output Receptacles (Load 1)
10 Output Receptacles (Load 2)
11 Output Receptacles (Load 3)
12 Input Circuit Breaker
13 10 ft. Power Cord
1
2000VA Model Only, L5-30R on 3000VA
2
750, 1000, & 1500VA Models Only
1
2
9
11
10
7
6
5
8
4
9
10
Minuteman EnterprisePlus LCD Series UPS2
Battery Characteristics
Extended Runtime Capability
All Extended Runtime (RTXL) models of the EnterprisePlus LCD
UPS come standard with internal batteries. To protect critical devices
through extended blackouts, the EnterprisePlus LCD UPS Series
utilizes external battery packs that can be daisy-chained in unlimited
quantities to provide a virtual unlimited amount of battery runtime.
Fast Battery Recharge (XL Battery Packs only)
With independent chargers in each battery pack oered for the
EnterprisePlus LCD UPS Series, the maximum recharge time for
depleted batteries is 8 hours, no matter how many battery packs are
installed on a UPS. Without these chargers, battery charging could take
more than an entire day if more than one battery pack is used.
Battery Pack Models
Because each UPS has dierent battery requirements to support its
maximum load capacity, the EnterprisePlus LCD Series uses battery
packs sized to match each UPS model:
• E750RTXL2U - BP36RTXL
• E1000RTXL2U - BP36RTXL
• E1500RTXL2U - BP36RTXL
Battery Technology
All EnterprisePlus LCD units and battery packs use valve-regulated
lead-acid batteries (VRLA). These are safe for any type of freight
transport. For added protection, all EnterprisePlus LCD UPS models
ship with batteries disconnected. A “Quick Installation Guide” is included
in each EnterprisePlus LCD box to detail how to connect the batteries
before turning on the units.
Hot-Swappable Batteries
The EnterprisePlus LCD UPS oers battery replacement, through
the front panel of the UPS, without having to remove the UPS from
service. Connected loads are protected from voltage anomalies and
spikes and surges while the batteries are being replaced.
• E2000RTXL2U - BP72RTXL
• E3000RTXL2U - BP72RTXL
New LCD Front Panel Display
EnterprisePlus LCD UPS products now feature an
informative LCD display. This display oers real-time
feedback on the following areas:
• Input / Output Voltage and Frequency Display to
monitor the status of your utility power
• UPS Battery Mode/Status Icons which eliminates
guesswork with a straightforward display of the UPS
status
• Load Capacity Indicator displays how much of a
connected load is being placed on the unit
• Numeric Estimated Runtime Display which is based on
the connected load to indicate how much backup time
remains during a blackout
Unit Status
Load Meter
Battery Meter
Numeric Display
(input, output
voltage and
frequency,
estimated runtime,
kVA, KW, error
codes)
Power On/O/Test
Alarm Silence
Display Scroll
Minuteman Support
• Minutemanups.com - Full product specications,
manuals, catalogs, FAQs, troubleshooting, & more
• SizeMyUPS.com - Easy-to-use interactive UPS sizing
site oering an extensive database of equipment power
ratings to guarantee proper UPS selection for your
system
SentryHD™ Management Software Included
Minuteman’s SentryHD™ UPS monitoring and control software comes included
with each EnterprisePlus LCD UPS unit at no extra charge. With SentryHD™ software,
users can monitor and control any new, and most legacy, Minuteman UPS products on
a connected network from one application session. The ease of installation, ease of
use, and backward compatibility makes it the best software of its kind.
• Support for 32/64-bit operating systems
(Compatible with Windows (XP, 2003,
2008 Server, Vista, 7 and 8) and Linux
operating systems.
• Batch conguration
• SNMP, (v1, v2c, v3), trap support
• Combined with Minuteman’s MM
Shutdown Agent, can control up to 255
devices
View the full line of EnterprisePlus LCD products at www.minutemanups.com/enterprisepluslcd3
• Supports scheduled UPS shutdown,
restart and battery testing
• Send e-mail and SMS alarm notices
• Supports both RS232 and USB
communication protocols
• Supports web browser access
through HTTP and HTTPs
EnterprisePlus LCD™ UPS Models & Specifications
Specications are the same for standard (RT2U), extended runtime (RTXL2U), and network card (NC) models except XL external battery packs
MODELS: STANDARD RUNTIME
Maximum Power Capacity (VA/Watts)750/6 001000/8001500/12002000/17603000/2560
TopologyLine Interactive, True Sine Wave Uninterruptible Power Supply
Power Factor0.80.80.80.880.853
Battery and Surge
Protected Receptacles
Input Connection (with 10 ft power cord)5-15P5-15P5-15P (6 -15 P)5-20PL5-30P (L6 -30P)
Mounting/InstallationRackmount/Tower and Wallmount
Number of PhasesSingle (1Ø 2W +G)
Nominal Voltage•Voltage Range120VAC (208VAC) • 80-164VAC (150-271VAC)
Frequency Range
Acceptable Input Voltage
Low Voltage Transfer Point80V (150V) resets to utility power at 85V (157V) or higher
High Voltage Transfer Point164V (271V) resets to utility power at 159V (264V) or lower
Input ProtectionResettable circuit breaker
Voltage Range • Voltage Regulation120VAC: 101-136VAC • -15.8% to 11.7% (208VAC: 186-236VAC) / -10.6% to +13.5%
Frequency Range •
Eciency (Line Mode)
Nominal Voltage120/125VAC (208/240VAC)
Voltage Regulation120VAC (208VAC) ±5% until low battery warning
Frequency±0.1Hz unless synchronized to line
Voltag e THD<5% at full rated linear load / <12% at full rated non-linear load
Dynamic Response • Transfer Time±10% @ 100% Load change in 30 ms
WaveformTrue Sine wave
Overload capacity110% for 20 seconds, 125% for 10 seconds, 150% shutdown immediately
ProtectionOver current, Short circuit protection and Latching shutdown
Ba t t ery Ty p eSealed, non-spillable, maintenance free, valve regulated lead acid
Typical Recharge Time8 hours from total discharge to 90%
Typical Battery Life3-5 years, depending on discharge cycles and ambient temperature
System Voltage36VDC36VDC36VDC72VDC72VDC
Battery ModuleBM0029BM0029BM0030BM0031BM0032
Runtime: Half •Full Load (minutes)17 • 815 • 511 • 413 • 5 8 • 3
Surge Energy Rating (Joules)1000J (800J)
Surge Current Capability6500Amps total
Surge Response time0ns(instananeous) normal mode: <5 ns common mode
Noise Filternormal and common mode EMI/RFI suppression
Audible Noise at 1 m (3 ft.)<45dBA<45dBA<45dBA<60dBA<60dBA
Temperature: Operating • Storage+32° to +104°F (0° to 40°C) • +5° to +113°F (-15° to +45°C)
Humidity: Operating/Storage95% non-condensing
Elevation: Operating•Storage0 to 10,000ft. (0 to 3,000m) • 0 to 50,000ft. (0 to 15,000 m)
Size: Net (L x W x H) in (mm)17.4 x 19.0 x 3.5 in (442.0 x 482.6 x 89.0 mm)24.0 x 19.0 x 3.5 in (610.0 x 482.6 x 89.0 mm)
Size: Shipping (L x W x H) in (mm)23.6 x 21.7 x 9.1 in (600.0 x 551.0 x 230.0 mm)39.4 x 23.6 x 9.1 in (1000.0 x 600.0 x 230.0 mm)
Weight: Net
Shipping
Battery PackBP36RTXLBP36RTXLBP36RTXLBP72RTXLBP72RTXL
Typical Recharge Time8 hours to 90% after full load discharge
Size: Net (L x W x H)17.0 x 19.0 x 3.5 in (432.0 x 482.6 x 89.0 mm)
Size: Shipping (L x W x H)23.6 x 21.7 x 9.1 in (600.0 x 551.0 x 230.0 mm)
Weight: Net • Shipping lb (kg)56.0 lb (25.4 kg) • 66.1 lb (30.0 kg)
Safety and ApprovalsRoHS2 Directive 2011/65/EU, cUL, CE, FCC Class B
Energy Star Certication1500, 2000, 3000VA Models Only