FrameMaker Ver.5.5E(PC) DIS/REASSEMBLY, ADJUSTMENT FOR Di152/Di183
01.09.03
Imaging Unit (IU)
NOTE
• When loading developer as part of the IU replacement procedure or when changing the
developer, remove the Toner Bottle and run “ATDC Sensor Automatic Adjustment” (F8)
twice to allow toner in the Spent Toner Recycling Duct and T oner Con ve ying Duct into the
Developer Mixing Chamber before removing the IU.
Dump the developer.
• Dump developer on the Sleeve Roller by turning
the gear in the direction of the arrow with the
Developing Unit tilted as shown.
• Note at this time that turning the gear backward
could damage the mylar for cleaning the ATDC
Sensor.
• Dump developer until almost no developer sticks to
the Sleeve Roller.
Pour one packet of developer.
NOTE
• Shake the packet of developer well before pouring.
• When the developer has been replaced, run
“ATDC Sensor Automatic Adjustment.”
☞
D-61