Minolta Di 152, Di 183 Disassembly Position of Scanner

FrameMaker Ver.5.5E(PC) DIS/REASSEMBLY, ADJUSTMENT FOR Di152/Di183
01.09.03
4-5. OTHER ADJUSTMENTS
(1) Adjustment of the Position of the Scanner and 2nd/3rd Mirrors Carriage
1. Fit the Scanner/Mirrors Carriage Positioning Jigs
Rear
in the space between the Scanner and the 2nd/ 3rd Mirrors Carriage.
2nd/3rd Mirrors Carriage
Jig
Rear
Adjusting Screw
Fixing Screw
Scanner
Jigs
2. Press the 2nd/3rd Mirrors Carriage tightly up against the jigs.
Jig
3. Loosen the set screw of the cable holding plate and turn the adjusting screw as necessary to eliminate clearance between the 2nd/3rd Mirrors Carriage and the Scanner/Mirrors Carriage Posi­tioning Jigs.
4. Press the Scanner tightly up against the jigs and tighten the set screw of the cable holding plate to the specified torque.