Minolta Di 152, Di 183 Disassembly Scanner Registration

FrameMaker Ver.5.5E(PC) DIS/REASSEMBLY, ADJUSTMENT FOR Di152/Di183
01.09.03
(5) Scanner CD Registration Adjustment
Requirement
• Adjust so that the deviation between width A on the test print and that on the copy falls within the spec­ified range.
A
4686D504AA
Specifications Mode Code No. Setting Range
0 ± 2.0 mm Adjust 5
NOTES
• This adjustment is made when the PH Unit has been replaced and after “Printer Regis­tration Adjustments (CD and FD)” and “Scanner Zoom Adjustment (CD).”
• Load the 1st Tray with A4C or 8-1/2 × 11C paper.
20 to 180,
1 step: 0.1 mm
<Adjustment Procedure>
1. Enter the Adjust mode.
2. With “AJ-” shown on the Display, enter the code number “12” from the 10-Key Pad.
3. Press the Paper key to select the 1st Tray.
4. Press the Start key.
Then, a test print will be produced.
5. Place the test print produced on the Original Glass and make a copy of it.
6. Align the test print (original) with the copy and check for deviation.
If the deviation between width A on the test print and that on the copy falls outside the specified range, perform the following steps to make an adjustment.
7. With “AJ-” shown on the Display, enter the code number “5” from the 10-Key Pad and
press the Start key to enter the “Scanner CD Registration Adjustment” mode.
8. Press the Clear key to clear the current setting value.
9. Enter the new setting value from the 10-Key Pad and press the Start key.
Adjustment Instructions If with A of the copy is longer than that on the test print, decrease the setting value. If with A of the copy is shorter than that on the test print, increase the setting value. If a single adjustment procedure does not successfully bring the deviation into the specifi ed range, repeat steps 6 though 8.
D-57
FrameMaker Ver.5.5E(PC) DIS/REASSEMBLY, ADJUSTMENT FOR Di152/Di183
01.09.03
(6) Scanner FD Registration Adjustment
Requirement
• Adjust so that the deviation between width B on the test print and that on the copy falls within the spec­ified range.
B
4022D502AA
Specifications Mode Code No. Setting Range
0 ± 1.5 mm Adjust 6
NOTES
• This adjustment is made when the PH Unit has been replaced and after “Printer Regis­tration Adjustments (CD and FD)” and “Scanner Zoom Adjustment (CD).”
• Load the 1st Tray with A4C or 8-1/2 × 11C paper.
60 to 140,
1 step: 0.1 mm
<Adjustment Procedure>
1. Enter the Adjust mode.
2. With “AJ-” shown on the Display, enter the code number “12” from the 10-Key Pad.
3. Press the Paper key to select the 1st Tray.
4. Press the Start key.
Then, a test print will be produced.
5. Place the test print produced on the Original Glass and make a copy of it.
6. Align the test print (original) with the copy and check for deviation.
If the deviation between width B on the test print and that on the copy falls outside the specified range, perform the following steps to make an adjustment.
7. With “AJ-” shown on the Display, enter the code number “5” from the 10-Key Pad and
press the Start key to enter the 2Scanner CD Registration Adjustment” mode.
8. Press the Clear key to clear the current setting value.
9. Enter the new setting value from the 10-Key Pad and press the Start key.
Adjustment Instructions If with B of the copy is longer than that on the test print, increase the setting value. If with B of the copy is shorter than that on the test print, decrease the setting value. If a single adjustment procedure does not successfully bring the deviation into the specifi ed range, repeat steps 6 though 8.
D-58