Minolta Di 152, Di 183 Function

FrameMaker Ver5.5E(PC) Di152/Di183 SWITCHES ON PWBs/TECH. REP. SETTINGS
01.07.26
3-3. Setting in the Tech.Rep.Mode
(1) Control Panel LED Check
• The LEDs on the control panel are made to blink to check for any LED that has burned out. Any LED that is not blinking is considered to be out.
• This function allows the Tech. Rep. to make the various function tests and adjustments.
<Procedure>
1. Enter the code number corresponding to the function to be used from the 10-Key Pad.
2. Press the Start key.
<Exiting the Mode>
• Press the Panel Reset key until the initial screen reappears.
Code No. Operation
<Paper Passage Test>
<HV Output>
<ATDC Sensor Automatic Adjustment>
<Test Pattern Output>
F-1
F-2
F-8
F12
Correct paper passage (paper transport path) is checked without involving any printing action. This test is used to check for a paper misfeed and transport path. <Procedure>
1. Select the paper source.
2. Press the Start key to start the paper passage cycle.
3. Press the Stop key to stop the paper passage cycle.
This test is for factory adjustment only and should NOT be used.
Adjusts the output level of the ATDC Sensor. This test is used when the copier is set up, developer is changed, and the IU is replaced.
For details, see DIS/REASSEMBLY, ADJUSTMENT.
Outputs a test pattern. (Halftone) This test is used to determine whether the engine is responsible for an image problem which has occurred or the IR is responsible for it. <Procedure>
1. Select the paper source.
2. Press the Start key to start the output sequence.
S-15
Loading...