Minolta Di 152, Di 183 Trouble Blank

FrameMaker Ver.5.5E(PC) Di152/Di183 TROUBLESHOOTING
01.09.04
5-4. Troubleshooting Procedures by Image Failure
(1) Blank copy
Section Step Check Result Action
Output system 1 Imaging Unit is installed correctly. NO • Reinstall.
2 Connector between the Imaging
3 PH Shutter (located along the
laser path between the PH Unit and PC Drum) is not in correct position or malfunctions.
4 PH Unit connectors PJ12A and
PJ13A are loose.
5 Image Transfer Roller Assy is
installed correctly.
6 Image transfer current contact is
dirty, broken, or bent.
7 Developing bias contact is dirty,
broken, or bent.
8 High Voltage Unit (HV1) connec-
tors CN1HV1 and CN2HV1 are loose.
9 The following voltage is supplied
from the Master Board (copier: PWB-A). <Check Procedure> Check voltage across a Master Board pin and GND when the Start key is pressed.
• Voltage across PJ8A-8 and GND DC14 V in standby state DC0 V when Start key is pressed
Input system 1 CCD Board (PWB-J) connector
JP7C is loose.
2 Control Board (copier: PWB-C)
connector PJ1A is loose.
YES • Clean.
YES • Correct or reinstall.
YES • Reconnect.
NO • Reinstall.
YES • Clean, correct, or
change.
YES • Clean, correct, or
change.
YES • Reconnect.
YES • Change IU.
• Change PH Unit.
• Change High Volt­age Unit (HV1).
NO • Change Master
Board (copier: PWB-A).
YES • Reconnect.
YES • Reconnect.
NO • Change Control
Board (copier: PWB-C).
• Change Master Board (copier: PWB-A).
T-45