FrameMaker Ver.5.5E(PC) Di152/Di183 TROUBLESHOOTING
01.09.04
(8) Void areas
Section Step Check Result Action
Output
system
1 Foreign matter is present along the
paper path.
2 Paper dust plugs up the Paper Dust
Remover.
3 PC Drum Charge Corona, grid mesh,
and Comb Electrode are loose.
4 PC Drum Charge Corona contact is
dirty, scratchy, deformed, worn, or damaged.
5 Developing Roller is dirty, scratchy,
deformed, worn, or damaged.
6 Toner is even on Sleeve/Magnet Roller. NO • Adjust DB.
7 Developer is not even in the Developer
Mixing Chamber of IU.
8 DB of IU is plugged with foreign matter
(such as paper dust).
9 Image Transfer Roller is dirty, scratchy,
deformed, worn, or damaged.
10 Image Transfer Roller Assy is installed
correctly.
11 Charge Neutralizing Plate is dirty,
scratchy, folded, or bent.
12 Left Fusing Roller is dirty, scratchy,
deformed, or worn.
YES • Rem ove foreign matter.
YES • Clean or change.
YES • Reinstall.
YES • Clean, correct, or
change.
YES • Clean or change.
For details, see DIS/
REASSEMBLY,
ADJUSTMENT.
YES • Even out developer in
the Developer Mixing
Chamber.
YES • Rem ove foreign matter.
YES • Clean, correct, or
change.
NO • Reinstall.
YES • Clean, correct, or
change.
YES • Clean or change.
NO • Change IU.
T-54