FrameMaker Ver.5.5E(PC) Di152/Di183 TROUBLESHOOTING
01.09.04
(7) Blank streaks or bands
Section Step Check Result Action
Output
system
Input
system
1 PC Drum ground terminal is dirty,
scratchy, deformed, or damaged.
2 DB of IU is plugged with foreign matter
(such as paper dust).
3 PC Drum Charge Corona grid mesh and
Comb Electrode are dirty, scratchy,
deformed, or damaged.
4 Post-fusing guide plate is dirty, scratchy,
deformed, worn, or damaged.
5 PH window of the PH Unit is dirty,
scratchy, or damaged.
1 Original Glass is dirty, scratchy, worn, or
damaged.
2 Shading sheet reading portion (the por-
tion on the backside of the Original
Glass to which Original Width Scale is
affixed) is dirty .
3 Scanner mirrors are dirty, scratchy, or
damaged.
4 CCD Unit lens and CCD surface are
dirty or scratchy.
<Check Procedure>
Remove lens cover to check for possible
contamination.
5 CCD Board (copier: PWB-J) connector
is loose.
6 Control Board (copier: PWB-C) connec-
tor PJ1A is loose.
YES • Clean, correct, or
change.
YES • Rem ove foreign matter.
YES • Clean, correct, or
change.
YES • Clean or change.
YES • Clean or change.
NO • Change IU.
YES • Clean or change.
YES • Clean.
YES • Clean or change.
YES • Clean or change.
YES • Reconnect.
YES • Reconnect.
NO • Change CCD Unit.
• Change Control Board
(copier: PWB-C).
T-53