Minolta CS-2000A, CS-2000 BROCHURE

For correct use and for your safety, be sure to read the instruction manual before using the instrument. Always connect the instrument to the specied power supply voltage.
Improper connection may cause a re or electric shock.
SAFETY PRECAUTIONS
The specications and drawings given here are subject to change without prior notice.
Certicate No : JQA-E-80027
Registration Date : March 12, 1997
Certicate No : YKA 0937154
Registration Date : March 3, 1995
2007 KONICA MINOLTA SENSING, INC.
67.4 79
70
392
253
51
50
47
Filter thread diameter: ø52
58.5
300
200
Reference for measuring distance
Optical axis
95.7 229.5
9
Mounting screw: M5, Depth: 6.5
Mounting screw: M5, Depth: 6.5
Tripod screw (ø3/8-inch screw)
Positioning pin hole (1): ø5, Depth: 4
5
6
Positioning pin hole (2): Depth: 4
90
158
190.4
170
ø15
120.5
129
Model CS-2000/2000A Wavelength range 380 to 780 nm Wavelength resolution 0.9 nm/pixel Display wavelength bandwidth 1.0 nm Wavelength precision ±0.3 nm (Median wavelength: 435.8 nm, 546.1 nm, 643.8 nm; Hg-Cd lamp) Spectral bandwidth 5 nm or less (half bandwidth) Measuring angle (selectable) 0.2° 0.1° Measurement luminance
range
(Standard light source A)
CS-2000 0.003 to 5,000 cd/m
2
0.075 to 125,000 cd/m
2
0.3 to 500,000 cd/m
2
CS-2000A 0.0005 to 5,000 cd/m
2
0.0125 to 125,000 cd/m
2
0.05 to 500,000 cd/m
2
Minimum measuring area
ø5 mm
(ø1 mm when using close-up lens)
ø1 mm
(ø0.2 mm when using close-up lens)
ø0.5 mm
(ø0.1 mm when using close-up lens) Minimum measuring distance 350 mm (55 mm when using close-up lens) Minimum spectral radiance display 1.0x10
-9
W/sr, m2, nm Accuracy: Luminance (Standard light source A)*1
±2%
CS-2000
Accuracy: Chromaticity (Standard light source A)*1
x,y :±0.003 (0.003 to 0.005 cd/m
2
)
x,y :±0.002 (0.005 to 0.05 cd/m
2
)
x : ±0.0015
(0.05 cd/m
2
or more)
y : ±0.001
x,y : ±0.003 (0.075 to 0.125 cd/m2) x,y : ±0.002 (0.125 to 1.25 cd/m
2
)
x : ±0.0015
(1.25 cd/m
2
or more)
y : ±0.001
x,y : ±0.003 (0.3 to 0.5 cd/m2) x,y : ±0.002 (0.5 to 5 cd/m
2
)
x : ±0.0015
(5 cd/m2 or more)
y : ±0.001
Repeatability: Luminance (2σ) (Standard light source A)*2
0.4% (0.003 to 0.05 cd/m
2
)
0.3% (0.05 to 0.1 cd/m
2
)
0.15% (0.1 to 5,000 cd/m
2
)
0.4% (0.075 to 1.25 cd/m
2
)
0.3% (1.25 to 2.5 cd/m
2
)
0.15% (2.5 to 125,000 cd/m
2
)
0.4% (0.3 to 5 cd/m2)
0.3% (5 to 10 cd/m
2
)
0.15% (10 to 500,000 cd/m
2
)
Repeatability: Chromaticity (2σ) (Standard light source A)*2
0.002 (0.003 to 0.005 cd/m
2
)
0.001 (0.005 to 0.1 cd/m
2
)
0.0006 (0.1 to 0.2 cd/m
2
)
0.0004 (0.2 to 5,000 cd/m
2
)
0.002 (0.075 to 0.125 cd/m2)
0.001 (0.125 to 2.5 cd/m
2
)
0.0006 (2.5 to 5 cd/m
2
)
0.0004 (5 to 125,000 cd/m
2
)
0.002 (0.3 to 0.5 cd/m2)
0.001 (0.5 to 10 cd/m
2
)
0.0006 (10 to 20 cd/m
2
)
0.0004 (20 to 500,000 cd/m
2
)
CS-2000A
Accuracy: Chromaticity (Standard light source A)*1
x,y :±0.002 (0.001 to 0.05 cd/m
2
)
x : ±0.0015
(0.05 cd/m
2
or more)
y : ±0.001
x,y : ±0.002 (0.025 to 1.25 cd/m
2
)
x : ±0.0015
(1.25 cd/m
2
or more)
y : ±0.001
x,y : ±0.002 (0.1 to 5 cd/m2) x : ±0.0015
(5 cd/m2 or more)
y : ±0.001
Repeatability: Luminance (2σ) (Standard light source A)*2
1.5% (0.0005 to 0.001 cd/m
2
)
0.7% (0.001 to 0.003 cd/m
2
)
0.25% (0.003 to 0.05 cd/m
2
)
0.15% (0.05 to 5,000 cd/m
2
)
1.5% (0.0125 to 0.025 cd/m2)
0.7% (0.025 to 0.075 cd/m
2
)
0.25% (0.075 to 1.25 cd/m
2
)
0.15% (1.25 to 125,000 cd/m
2
)
1.5% (0.05 to 0.1 cd/m
2
)
0.7% (0.1 to 0.3 cd/m
2
)
0.25% (0.3 to 5 cd/m
2
)
0.15% (5 to 500,000 cd/m
2
)
Repeatability: Chromaticity (2σ) (Standard light source A)*2
x: 0.003 y:0.0035
(0.001 to 0.003 cd/m2)
x: 0.001 y:0.0015
(0.003 to 0.1 cd/m2) x,y: 0.0006 (0.1 to 0.2 cd/m2) x,y: 0.0004 (0.2 to 5,000 cd/m
2
)
x: 0.003 y: 0.0035
(0.025 to 0.075 cd/m2)
x: 0.001 y: 0.0015
(0.075 to 2.5 cd/m2) x,y: 0.0006 (2.5 to 5 cd/m2) x,y: 0.0004 (5 to 125,000 cd/m
2
)
x: 0.003 y: 0.0035 (0.1 to 0.3 cd/m2) x: 0.001 y: 0.0015 (0.3 to 10 cd/m
2
)
x,y : 0.0006 (10 to 20 cd/m
2
)
x,y : 0.0004 (20 to 500,000 cd/m
2
) Polarization error 1°: 2% or less (400 to 780 nm); 0.1° and 0.2°: 3% or less (400 to 780 nm) Integration time Fast: 0.005 to 16 sec.; Normal: 0.005 to 120 sec. Measurement time 1 sec. minimum (Manual mode) to 243 sec. maximum (Normal mode) Color space mode
Lvxy, Lvu'v', LvTuv, XYZ, spectral graph, dominant wavelength, excitation purity, scotopic luminosity (with CS-S10w Professional) Interface USB 1.1 Operating temperature/
humidity range
CS-2000 : 5 to 35°C, relative humidity 80% or less with
no condensation
CS-2000A : 5 to 30°C, relative humidity 80% or less with
no condensation Storage temperature/humidity range 0 to 35°C, relative humidity 80% or less with no condensation Power AC adapter (100 - 240 V
, 50/60 Hz) Current consumption Approx. 20 W Size 158 (W) x 200 (H) x 300 (D) mm (Main unit), ø70 × 95mm (Lens) Weight 6.2 kg
*1: Average of 10 measurements in Normal mode at a temperature of 23±2°C and a relative humidity of 65% or less. *2: 10 measurements in Normal mode at a temperature of 23±2°C and a relative humidity of 65% or less.
Major specications of CS-2000/2000A
Spectroradiometer
CS-2000/2000A
NEW
The world's top-level capability spectroradiometers make further advances with addition of second model to lineup.
Outer dimensions
(Units: mm)
9242-4892-10 BACDPK 5 Printed in Japan
With this software, the CS-2000 and CS-2000A can be controlled from a personal computer to display measured data in various graphs or lists, to transfer data to spreadsheet software, or to copy-and-paste data. CS-S10w offers various data management, analysis and evaluation options to assist in research and development or quality control.
Display Spectral graph, spectral data list, chromaticity diagram Color space mode L
v
xy, Lvu'v', LvT uv, XYZ, dominant wavelength,
excitation purity, scotopic luminosity
Calculation Four basic arithmetic operations and
function processing of spectral data
Mode selection Normal mode, contrast mode, RGB mode, RGB &
contrast mode, object color mode
Instrument control Averaging measurement, interval measurement, user calibration Data management Reading/saving les; managing data by using folders;
creating, saving and reading templates with various graphs designed and laid-out by users; displaying data with graphs
Data evaluation Observer/illuminant setting, color rendering property evaluation,
statistic value display for each folder, box tolerance setting, multiple point setting for display evaluation, non-uniformity (mura) display, contrast display, polygonal tolerance setting
Multiple data objects can be copied and pasted to spreadsheet software.
Template showing xy and u'v' chromaticity diagrams
• Wi nd ow s
®
is a tr ad em ark or re gi st ered tra dema rk of Microsoft Corporation in the USA and other countries.
• Pentium
®
is a trademark of Intel Corporation
in the USA and other countries.
Data Management Software CS-S10w Professional (Standard accessory)
System requirements OS Windows
®
2000 Professional SP4,
Windows
®
XP Professional SP2/×64 Edition,
Windows
®
Vista Business 32-bit/64-bit
CPU Pentium
®
III 600 MHz equivalent or faster Memory 128 MB or more (256 MB or more recommended)
Hard disk 60 MB or more of free space for installation Display 1024 x 768, 256 colors minimum Other CD-ROM drive for installation, USB port
for instrument connection
Color LCD screen
Color space mode screen
Menu screen
cd
m
2
Lv
30 . 79
0 . 3211
0 . 3404
x
y
cd
m
2
Lv
30 . 79
6027K
+0 . 005
T
duv
Simple
operation
The desired function can be called intuitively.
Easy connection via USB
Easy operation with color LCD screen and simple operation panel
The color LCD screen and operation panel are located at the rear of the instrument. The simply arranged operat ion panel enables intuitive selection of necessary functions.
LCD pixels
Measurement Examples
Organic EL
Average repeatability (logarithm)
Average repeatability (logarithm)
100
10
1
0.1
Average repeatability (logarithm)
Average repeatability (logarithm)
100
10
1
0.1
Average repeatability (logarithm)
Average repeatability (logarithm)
100
10
1
0.1
CS-2000
CS-1000
CS-2000
CS-1000
CS-2000
Luminance ( Lv ) Chromaticity ( x ) Chromaticity ( y )
CS-1000
Difference:
24.7 times
Difference:
24.7 times
Difference:
34.7 times
Difference:
34.7 times
Difference:
24.3 times
Difference:
24.3 times
AC Adapter
Eyepiece with ND filter
CS-A1
Calibration certificate(CS-2000) 3-point calibration certificate (CS-2000A)
CCD Camera Adapter
CS-A36
CS-2000 main unit
USB cable (2 m) CS-A32
Personal computer
(commercial product)
Standard accessories
Optional accessories
ND filter (1/10) CS-A33 (1/100) CS-A34
Lens Cap
Data Management
Software
CS-S10w
Professional
Edition
Close-up lens
CS-A35
White Calibration Plate
CS-A5 (without data) CS-A5 (with data) CS-A5 (with data
and calibration certificate)
Storage Case
CS-A30
Pan Head
CS-A4
Tripod
CS-A3
LCDPDP
Measuring diameter viewed through
viewnder
System Conguration
Measuring distance vs. measuring area (Units: mm)
Measuring distance
Measuring angle
0.2° 0.1°
When a close-up lens
is attached
55.0 ø1.00 ø0.20 ø0.10
70.9 ø1.39 ø0.28 ø0.14
350 ø5.00 ø1.00 ø0.50
500 ø7.78 ø1.56 ø0.78
1,000 ø16.66 ø3.33 ø1.67
2,000 ø34.18 ø6.84 ø3.42
* The measuring distance is the distance from the objective lens or the end of the metal frame
of the close-up lens.
High repeatability achieved by an instrument design which thoroughly eliminated mechanical and electrical noise factors.
1° is suitable for
Typical targets such as middle- and large-size display units
• LCD, PDP, or EL display panels
• LCD panels of cellular pho nes and
digital cameras
• Radar and other instrument panels
used in airplane cockpits
• Large outdoor display screens
0.2° is suitable for
Small light sources such as LEDs
• Car audio systems
• Instrument panels for automobiles
• Lamps, fluorescent tube backlights,
and other light sources
0.1° is suitable for
Extremely small light sources or distant lights
• PDP or LCD pixels
• Cold-cathode tubes
• Brake lamps of automobiles
• Traffic signals
Optional close-up lens allows measurements of areas as tiny as ø0.1 mm. Not only general display units but also small targets can be measured.
It is known that the sensitivity of human vision shifts to blue region in dark environments, but past instruments did not have scotopic measurement
function. CS-2000A achieves sufcient capability to make it possible with
CS-S10w Professional (standard accessory).
Scotopic vision
In the human eye, there are 2 types of photoreceptor cells, which are cone cells and rod cells. Cone cells are sensitive to color and rod cells are sensitive to only brightness. As brightness decreases, the activity of rod cells becomes stronger, and the condition in which only rod cells are working is called scotopic vision. The peak of spectral luminous efficiency of scotopic vision is shifted toward blue from the green peak of photopic vision (vision under brighter conditions) and thus blue objects are perceived to be brighter.
Measurements of various objects are possible by selecting the best-suited measuring angle.
Measured luminance vs. Measurement times
(Units: sec.)
Scotopic vision measurement
Close-up lens for measurement of even tinier areas
(Optional accessory)
Comparison of repeatability
* Comparison with Konica Minolta's previous model CS-1000 for target luminance of 0.1 cd/m
2
* The y-axis indicates the logarithm when the average of the CS-2000 measured values is assumed to be 1.
380
1.2
1.0
0.8
0.6
0.4
0.2
0.0
411
442
473
504
535
566
597
628
659
690
721
752
CIE Spectral luminous intensity
Wavelength [nm]
Photopic Scotopic
Luminance (cd/m2) NORMAL mode FAST mode
0.003 243 35
0.01 243 35
0.1 155 27 1 19 5
10 4 4
300 3.7 3.7
Measurement subject: Standard light source A
* All time indications are approximate values.
Thermal analysis diagram
of the sensor block
The o ptic al sen sor, which is the heart of the CS-2000, was designed through precise analysis in order to eliminate the influence of thermal distortion of its components on the measurement values.
World's top level capability to detect extremely low luminance
* As a polychromator type spectroradiometer (As of March 2009)
1,000,000:1 contrast measurement is now possible!
* When the peak luminance is 500 cd/m
2
Opening the curtain on a new age in which people can experience theater ambiance with their home televisions. The Spectroradiometer CS-2000A enables high-accuracy mega-contrast measurements of the extremes from delicate shadows to glittering wavefronts which are key to image reproduction performance. This newest addition to the Konica Minolta Sensing lineup will contribute greatly to research and development as well as quality control of the most advanced FPDs.
0.0005 cd/m2 opens new worlds
With an additional decimal place of performance in measuring low luminosity even compared to our CS-2000, which was awarded the ADY 2008 grand prize, the CS­2000A helps open up a new stage of display development by enabling the measurement of contrast ratios up to 1 million to 1*1 which is being targeted by the latest FPD technology.
*1 Maximum luminance 500 cd/m
2
Highly accurate measurement of luminances as low as 0.003 cd/m
2
Konica Minolta's original optical design and signal-processing technologies provide accurate measurement of luminance/ chromaticity down to extremely low luminances of 0.003 cd/m
2
.
Low-luminance measurements: From 0.003 cd/m
2
Measurement accuracy: ±2% (Luminance)
Quick measurements even at low luminance
Designed to thoroughly eliminate mechanical and electrical noise factors, the CS-2000 makes quick measurements with good repeatability possible even at low luminance levels.
Measurement time for 1 cd/m
2
:
Approx. 5 sec. (FAST mode)
* Konica Minolta's previous model CS-1000: Approx. 123 sec.
Low polarization error
The polarization error generated when using a reflection­type diffraction grating has been minimized to 2% (measuring angle: 1°). This ensures more stable measurements of display devices that use polarization, such as LCDs.
Half bandwidth of 5 nm
A half bandwidth of 5 nm, which is required for colorimetry (JIS Z 8724-1997, CIE122-1996), is ensured for the entire wavelength range, allowing accurate chromaticity measurements.
Measurement example: Measurement of an organic EL illumination panel during development
CS-2000
NEW
CS-2000A
Selectable measuring angle for measurement of tiny areas
The CS-2000 enables you to select the optimum measuring angle according to the application.
Measuring angle selection: 1°, 0.2°, 0.1°
Minimum measuring area: ø0.1 mm ( when the optional close-
up lens is attached)
Practical design
• The operating temperature range of 5 to 35°C ensures
relia bl e op er ation at t em perat ur es i n ac tu al w or k environments.
• Measurement can be started after a warm-up time of only 30 seconds. (Measuring angle: 1°; Target luminance: 5 cd/m
2
or more; 23°C)
Stable measurement even of periodic light sources
1. Internal synchronization measurement
Measurement at numerically-input frequency
2. External synchronization measurement
Measurement with line input of vertical synchronization signal to instrument
3. Multi-integration mode measurement
Measurement for reducing variations due to unsynchronized measurements or synchronized measurements of sources having irregular light-emission cycles
Instruments that push the extreme boundaries of practical application and cost performance to support design and development work.
Technology