Minolta CM-3600D, CM-3610D BROCHURE

Built for Precision, Priced for Economy
Outstanding Performance through Innovative Technology
CM-3600d Horizontal Spectrophotometer
Highly accurate, reliable and rugged Versatile instrument for most colorimetric applications Simplified operation.
CM-3610d Vertical Spectrophotometer for best application support
Speeds up textile and paper measurements Ideal for non contact measurements such as powders, pigments Quick sample handling and observation
SpectraMagicTMNX enables you to perform comprehensive color inspection and analysis of incoming raw materials, in process production, and outbound color critical goods and mate rials in virtually any industry. With SpectraM agicTMNX you can insert digital images with measured data. Measure samples in any of 8 universally accepted color spaces. Select from 15 illuminants, and up to 40 indices to determine specific color and appearance properties, such as strength, brightness, haze, yellowness, opacity and strength. You can even configure up to 3 customized color equations. Reports range from simple Pass/Fail to trend charts, histograms, color plots, and spectral graphs. SpectraMagicTMNX comes with predefined templates using skin technology, or you can create your own templates. For illustrations and explanations to understanding color and color measurement technology, there is a link to Konica Minolta's well known and respected “Precise Color Communication”. Step by step navigation help.
• Windows®is a trademark of Microsoft Corporation in the USA and other countries.
Supports Windows®2000/XP/Vista
SpectraMagicTMNX
(
Optional
)
Performance
Fast, simultaneous measurement of Specular Included and Specular Excluded components (SCI/SCE)
Versatility
Full wavelength range 360-740nm with 10nm pitch
Reliability
CM-3600d and CM-3610d Spectrophotometer:
Highest Quality in Color Measurement
in the Laboratory and for Production
High reliability design with fewest moving parts of any benchtop spectrophotometer
Large (6") sphere; di:8°, de:8° geometry Reflectance and transmittance sample measurements Changeable measurement areas (ø4mm,ø8mm,or ø25.4mm) View finder design for easy sample viewing Compact and lightweight
Fast, Instantaneous numerical UV adjustment enables UV-included, UV-excluded, and UV-adjusted data to b e obtained simultaneously Precise inter-instrument agreement. All CM-3600d spectrophotometers meet published inter-instrument agreement.
Maintenance free technology and ruggedness concept
The CM-3600d is equipped with maintenance-free technology and solid state components to withstand rugged conditions. The monolith polychromator unit assures highest durability and stability. With one exception (Observing Lens), the CM-3600d does not use any moving parts. Furthermore, each CM-3600d passes a hard endurance test program to comply with KONICA MlNOLTA's highest quality standards in accordance with ISO-9001.
Compact but yet Powerful
Behind the compact and space­saving design, you'll find the skills of a top­class instrument with 6" large sphere and other functions so far only found in much larger and more expensive
Full range of application coverage
Konica Minolta Innovative Optical System Technology
Multiple measurement area selection
For high-accuracy color control The newly designed Monolith Polychromator Unit
Bright and clear sample viewing system
Designed to meet your highest ergonomic expectations
1.Numerical Gloss Control
Enhanced Performance Technology Konica Minolta Innovative Optical System
2.Numerical UV Control
This technology also provides:
SCI specular component included SCE specular component excluded
UV-adjusted data
LAV
25.4mm
MAV 8mm
SAV
4mm
Konica Minolta's Innovative Optical System, including Numerical Gloss Control and Numerical UV Control, opens the way to unlimited application versatility at a price level never seen before.
Whatever your sample looks like, with the CM-3600d you can measure it! Reflectance of opaque samples, Transmittance of transparent liquids or solids and Diffuse Transmittance of translucent materials such as plastics - the CM-3600d is truly versatile.
Transmittance Measurement-The CM-3600d employs the d:0° geometry (diffused lighting, 0° viewing), which conforms to ISO, DIN, CIE, and ASTM standards.
Reflectance Measurement-The CM-3600d employs di:8°, de:8° geometry (diffused lighting, 8° from normal viewing) which conforms to JlS7 ISO, DIN, CIE and ASTM standards.
consists of a diffraction grating with a full wavelength range, 360-740 nm, at 10nm pitch, and 10nm half-band width, both for sample and reference light, and dual-channel sensor array.
The retro mirror's reflected and illuminated sample viewing screen minimizes fatigue and allows trouble-free sample observation.
The compact and space-saving body as well as all functions of the CM-3600d have been designed to ensure easy and fatigue-free operation in daily use. The bright mirror sample viewing system, the sample holder for up to A4 size samples with full 90° lock down, and the versatile Transmittance chamber for liquid or translucent samples are all just where you expect them to be for easy operation.
To cover all kinds of samples, the CM-3600d gives you the choice among three aperture sizes: LAV 25.4mm, MAV 8mm and SAV 4mm with precise measurement spot adjustment by a motorized observing lens.
The CM-3600d and CM-3610d are equipped with Konica Minolta Innovative Optical System technology. For users, this means high accuracy and repeatability, improved performance, additional features, simple operation, and - low, affordable pricing.
Instead of using a mechanically driven gloss trap, the CM-3600d and CM-3610d feature a patented numerical Gloss (SCl/SCE) control system. By sequentially firing two flashes, within a few seconds the system provides both SCI and SCE values for each sample.
To replace the time-consuming traditional UV measurement system that utilizes moving filters, the CM-3600d introduces yet another patented numerical calculation system, which is also part of the CM-3610d: The measured values of two sequentially fired flashes, one with full UV ener­gy and one with UV cut-off filter at either 400 or 420 nm are combined to obtain the spectral characteristics, and the respective whiteness and tint value of any UV-activated fluorescence sample. To avoid triplet effect on FWA treated samples, the CM-3600d and CM-3610d can be set to Soft-Flash mode. Numerical UV Control technology makes faster, more effective and reliable measurements of FWA treated materials such as textiles, papers and detergents.