Minka Group F502-BCW User Manual

TRADITIONAL GYRO
BY
TM
U.S. Patents: D523,548; D523,549; D523,550; D523,983; D524,438; D526,059; D526,400;
D526,712; D530,810; D532,097; D567,350; 6,832,902; 7,183,680; 7,229,255 © 2004 Minka Lighting, Inc.
INSTRUCTION MANUAL WARRANTY CERTIFICATE
This product is protected by United States Federal and/or State Law, including Patent, Trademark and/or Copyright laws. Manual design and all elements of manual design are protected by U.S. Federal and/or State Law, including Patent, Trademark and/or Copyright laws.
Minka-Aire warrants to the original owner that this fan will be free from defects in material and workmanship for one
year from the date of purchase, excluding the motor. Minka-Aire warrants to the original owner that the motor in this fan
R
R
shall be free from defects in material and workmanship for as long as the original purchaser owns the fan, and it remains in
This is a limited warranty. Minka-Aire's only obligation under this limited warranty is to replace or repair, or refund the purchase price, in Minka-Aire's sole discretion without charge to the original owner, of the fan once Minka-Aire confirms that the fan has a defect covered by this
R
limited warranty. Call our customer service department at 1-800-307-3267 to obtain the name of the Minka-Aire authorized dealer closest to your location, or contact us through our web site, www.minkagroup.net and write to: Ask Mr. Minka if you have any questions or require further assistance. To obtain warranty service, the owner should return the fan along with proof of purchase to a Minka-Aire authorized dealer. The Minka-Aire authorized dealer shall then, at its sole discretion: repair the fan, replace the fan, refund the purchase price less the amount directly attributable to the consumer's prior usage of the fan, or if necessary instruct the consumer to contact Minka-Aire directly for warranty service. Minka-Aire will be responsible for the cost of any repair, or replacement for any warranty service provided by a Minka-Aire authorized dealer for product under warranty. You may also at your preference obtain warranty service by returning the fan directly to Minka-Aire along with proof of purchase, your name and return address, and a description of the claimed product defect. Pack carefully; damage sustained in return transit to Minka-Aire will be the
the original installation.
R
R
R
R
R
R
R
R
R
original owner's responsibility. Original owner shall be responsible to pay all shipping charges. To obtain warranty service, you may return a fan that proves to be defective during the warranty period to the following address: Minka-Aire - Warranty Service, 1151 W. Bradford Court, Corona, CA 92882
R
R
This warranty shall not apply to fans which have been damaged in any way, including improper installation, damage as a result of the removal of the fan from the origial installation, or damage in shipping. This warranty shall not apply to fans which have been subjected to use for which the fan was not designed. The purchaser of the fan shall be responsible for any cost of removing the old fan, installing a new fan, or any other costs. This limited warranty is in lieu of all other express warranties. This limited warranty excludes all incidental and consequential damages, and Minka-Aire shall not under any circumstances be liable for incidental or consequential damages. Some States do not allow the exclusion of or
R
limitation of incidental or consequential damages, so the foregoing limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from State to State. We encourage you to promptly complete and return the enclosed warranty registration card. However, return of the warranty registration card is not a condition of this warranty.
Date Purchased Store Purchased Model Number Serial Number
F502
SAFETY RULES....................................................................................
PACKAGE CONTENTS.....................................................................
INSTALLING THE FAN.....................................................................
HANGING THE FAN.........................................................................
ELECTRICAL CONNECTIONS.......................................................
INSTALLING THE WALL TRANSMITTER.................................
FINISHING THE INSTALLATION................................................
1151 W. Bradford Court, Corona, CA 92882 For Customer Assistance Call: 1-800-307-3267
INSTALLING THE LIGHT BULB AND GLASS SHADE.....................
1
ADJUSTING THE TILT ANGLE..................................................................
2
OPERATING YOUR REMOTE CONTROL/WALL TRANSMITTER...
3
CARE OF YOUR FAN....................................................................................
4
TROUBLESHOOTING.................................................................................
5
SPECIFICATIONS..........................................................................................
6 7
10
11 12 13
8
CONTENTS
9
U
R
L
LISTED E75795
1
SAFETY RULES
1. Before you begin installing the fan, shut power off at the circuit breaker of the fuse box.
2. Be cautious! Read all instructions and safety information before installing your new fan. Review accompanying assembly diagrams.
3. Make sure that all electrical connections comply with local codes, ordinances, or National Electrical Codes. Hire a qualified electrician or consult a do-it-yourself wiring handbook if you are unfamiliar with installing electrical wiring.
4. Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 10 feet from the floor and 18 inches from the tip of the blades to the wall.
5. If you are mounting the fan to a ceiling fan outlet box, use a U.L. Listed metal octagonal outlet box marked "Acceptable for Fan Support". Secure the box directly to the building structure. The outlet box and its support must be able to support the moving weight of the fan (at least 50 pounds) Do not use a plastic box.
6. Caution: To reduce the risk of injury use only the screws provided with the outlet box in conjunction with the lock washers provided with the fan.
7. If you are mounting the fan to a joist, make sure it is able to support the moving weight of the fan (at least 50 pounds).
8. After you install the fan, make sure that all mounting components are secured to prevent the fan from falling.
9. Do not insert anything into the fan blades while the fan is operating.
10. Turn the fan off and wait for the blades to stop completely before performing any maintenance or cleaning.
ATTENTION:
ATTENTION:
The Energy Policy Act of 2005 requires this fan to be equipped with a 190 watt limiting device. If lamping exceeds 190 watts, the
ceiling fan's light kit will shut off automatically.
NOTE: The important safeguards and instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur. It must be understood that common sense, caution and care are factors which can not be built into this product. These factors must be supplied by the person (s) installing, caring for and operating the unit.
NOTE: READ AND SAVE ALL INSTRUCTIONS!
SUPPORT DIRECTLY FROM BUILDING STRUCTURE.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR OTHER PERSONAL INJURY. MOUNT FAN DIRECTLY TO THE BUILDING JOIST USING THE WOOD SCREWS AND
WASHERS PROVIDED WITH THE FAN. THE WOOD SCREWS MUST GO THROUGH THE OUTLET BOX VIA THE KNOCK OUTS. CONSULT A QUALIFIED ELECTRICIAN IF IN
TO REDUCE THE RISK OF PERSONAL INJURY, DO NOT BEND THE BLADE HOLDERS WHILE INSTALLING, BALANCING THE BLADES, OR CLEANING THE FAN. DO NOT
INSERT FOREIGN OBJECTS BETWEEN ROTATING FAN BLADES.
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE.
DOUBT.
2
PACKAGE CONTENTS
Unpack your fan and check the contents. You should have the following items:
1. Fan motor assembly
2. Hanger bracket plate
3. Hanger bracket
4. Canopy
5. Canopy cover 6a. Standard downrod assembly 6b. Minimum-length downrod (for close to
ceiling mounting only)
7. Decorative ring
8. Decorative scroll (2)
9. Coupling cover
10. Glass shade
11. 100W halogen bulb
12. Metal light cap
13. Receiver with 6 wire nuts 14a. Wall transmitter Incl. 2 mounting
screws and 3 wire nuts
14b. Wall plate w/2 mounting screws
15. Extra Wall Plate w/2 Mounting screws A. Mounting hardware:
#14 X 3.5" Wood screws (2 PCs.) Lock washers (2 PCs.) Star washers (2 PCs.) Wire nuts (3 PCs. ) Washers (2PCs.)
6a 6b
1
A
2 3
4
5
7
8
9 10
11
12
13
14a
14b
15
Tools Required: Phillips screw driver; slotted screw driver; pliers; wire cutters; electrical tape.
MOUNTING OPTIONS
If there is not an existing mounting box, then read the following instructions. Shut the power off at the circuit breaker or fuse box.
Secure the hanger bracket directly to the building structure via the knock outs from the outlet box. The building joist and its support must be able to fully support the moving weight of the fan. Figures 1, 2 and 3 are examples of different ways to mount the outlet box. Note: You may need a longer downrod to maintain proper clearance when installing on a steep, sloped ceiling,. Longer downrods are available from your Minka-Aire
To hanger your fan where there is an existing fixture but no ceiling joist, you may need to install a hanger bar as shown in Fig. 4 (available at your Minka-Aire
®
dealer.
®
dealer.)
INSTALLING THE FAN
CEILING JOIST OR
CROSS BRACE
FIG. 2
OUTLET BOX
FIG. 4
PARALLEL WOOD BRACE
HANGER BAR (OPTIONAL)
CROSS BRACE
CEILING
jOIST
FIG. 1
ANGLED CEILING MAXIMUM 20 ANGLE
RECESSED OUTLET BOX
FIG. 3
CEILING
JOIST
OUTLET BOX
PROVIDE STRONG SUPPORT
HANGER OPENING must be FACIN G UPSIDE
(MIN. 2" THICK)
OUTLET
BOX
CEILING
JOIST
HANGER BRACKET
3
Loading...
+ 18 hidden pages