Miniware MDP-M01 User guide

Page 1
MDP-M01
User Manul Of Display Control Module
Before using this product, please read this manual
(This user's manual written based on firmware version V1.20)
Page 2
table of Contents
Key description
Waveform diagram interface WARE
DETAIL detailed list of information
SET interface
Upgrade
Appendix 1 Description
2
4
4
4
5
9
9
1
Page 3
Key Description
Waveform
display area
2
Output Area
Key
functiareas
Voltage Range
1
Current Range
figure 1
Setting area
Input area
Temperature
display
Sub-module display area
3
The trackwheel
Under the dial
Pilot lamp
FIG 1 interface buttons corresponding to the bottom of its key function, when the key gray background when the key is not representative of the current.
(MODIFY) Edit mode: If you want to change certain values must click the button to enter the next level editing mode;
A
(PLAY / STOP) Playback Stop: stop or playback waveform;
B
(The CHANNEL) Channel: Wireless channel switching (i.e. a table for selected power supply);
C
(DETAIL)details interface;
D
(the SET)setting interface;
E
Screenshot (long press): in order to be saved screenshot U disk;
on the dial: Similar cursor jumps, i.e. choose a place to be edited;
under the dial: change value;
2
Page 4
(the NEXT) Next a: a turn to the numerical modification mode;
(the BACK) Returns: Returns to the previous editing mode;
(the CONFIRM) acknowledgment;
(the WAVE) waveform interface;
(the HELP) help.
Edit mode:
Note: when adjusting the settings set current or voltage, which can not exceed the total power is 90W.
Step one: Click the MODIFY button, the following figure:
Select the current or voltage
(Orange color selected module)
Turn to a lower value
Modify Mode
Step Two: Click the NEXT button, the following figure:
Go back to the
previous Edit mode
In the selected voltage, the
rotation of the pulley to move
the selected specified values,
the rotation of the lower
pulley to change the
numerical size
Go back to the previous
Edit mode
3
Page 5
Waveform diagram interface WARE
WARE interface reference waveform diagram shown in FIG 1:
Range Adaptive. The voltage at the current time into 0ms removed from the queue, the queue to find the maximum
1
value with the minimum and maximum voltage change range is plus 500mV, the minimum value Save 2500 mV, and the current range is the maximum current is applied according to 800mA, Save minimum 300mA.
Axis can be adjusted on the dial.
2
1.
3
break extension, which corresponds to the numerical values of the background turns red channel, reconnection can restore its original color.
2.
When no power source is connected, the key under the ribbon jump prompts to Auto Match interface (FIG. 1.1) matching wireless connection.
Lamp status
Blue indicator lights: Always running lights.
Red light: the extension case warning lights.
DETAIL detailed list of information
Voltage may be provided
Current may be provided
Real-time voltage
Real-time current
Real-time power
Category List
A detailed list of
information
Input voltage
Input current
Corresponding to the temperature
Of the power machine lock
When the display is locked, there is no way to control the display and control the power machine, can only view information.
ON / CC / CV / OFF
Key functional areas
4
Page 6
SET interface
Channel Category List
Automatic wireless
address Matching
buttons
Empty radio address
And ID
Wireless Address
Radio frequency
Automatic wireless
address Arrange
button
Hardware or software
version information
Key functional areas
a)
Addr: wireless address is connected.
Freq (GHz): is a radio frequency connection.
b)
May be individually modified with radio frequency wireless address Addr or Freq (GHz) list.
Step one: Click the MODIFY button, the following figure:
(GHz)
Turn to a lower value
Modify Mode
Go back to the previous
Addr or select Edit mode Freq
5
Page 7
Step Two: Click the NEXT button, the following figure:
In Addr selected, the rotation of the pulley to move the selected specified value, the rotation of the pulley to change the size of the value
Go back to the previous
Edit mode
Clear ID && Addr: Remove all power and the corresponding wireless addresses match the ID number, and can
c)
not automatically deleted Line address file.
OK button
Version: includes hardware and software version information.
d)
devise serial number
Cancel button
hardware version
Software version
Cancel button
6
Page 8
There are three display control method may be paired with the wireless power sub-modules, are as follows e, f, g:
e)
Auto Match:Automatically match with the address with a wireless radio frequency power.
Auto Match sub-interface:
Wireless starting address
Radio frequency
OK button
Figure 1.1
Cancel button
Start Addr: automatic matching requires the starting address of the wireless slave device, each additional slave units in the wireless address Finally, the cumulative value of 1;
Freq: automatic matching of the radio frequency required slave.
Wireless starting address
Radio frequency
Cancel button
Wireless connectivity title
It is matching
Figure 1.2
Wireless Address
Radio frequency
page number
Figure 1.3
7
Page 9
Display and Control: select "Auto Match" button, to enter the above interface sub Auto Match (FIG. 1.1), then Confirm
Click the OK button to enter Figure 1.2, matching the wireless connection, and then waits for a reply pairing wireless
power supply.
Power: Press the power button MENU intermediate, then move the pulley to a menu page provided Tx and Rx Addr(Figure
1.3), and then click the left button SET. As can be matched successfully, the wireless list box on the SET display and control
interface, a power menu page provided Tx and Rx Addr (Figure 1.3) is displayed above the address of wireless radio
frequency with the matching succeeds.
f)
Auto Sort: Sort automatically with radio frequency wireless address. (This pairing for power wirelessly Has good access in
sequence, the power supply has been completed or modifications as are suited to the address with a wireless radio
frequency through the U disk).
Auto Sort sub-interface:
Matching the number of
channels
Wireless starting address
Radio frequency
OK button
Ch Num: the number of the slave to be sorted;
Start Addr: need to sort the originating wireless address of the slave, each additional slave units, most
radio addresses After the values incremented by 1;
Freq: a radio frequency to be sorted slave.
Cancel button
g) Into the U can display and control panel to change the radio address to match with the radio
frequency power supply, its file name is RX_ADDR.TXT, the contents of the file as shown below, changes
will take effect after reboot.
Wireless Address
Radio frequency
file name
8
Page 10
Note:
1) To add a new sub-module , Click "Clear ID && Addr" function to delete the old ID to save the information,Again the
match in order to connect to the host.
2) Radio frequency 2405MHz-2478MHz.
3) If the currently selected sub-equipment dropped,it will automatically jump to the other sub-selected on the device is
online.
4) When radio address matching, if the power output to open their own,based on security issues, will be forced to shut
down Power Output.
Upgrade
A press of the display and control keys, and also with a USB cable usb computer, the computer will appear named:
DFU Vx_xx_x removable hard disk, the prepared .hex firmware copied to the root directory of the mobile hard disk,
when the extension by the firmware .hex become .rdy, restart the display and control, to complete the firmware
upgrade.
Appendix 1 Description
Note that (abnormalities alarm description):
1) Because the U disk inside the factory does not need to put files in there, so do not read a file Check;
2) Interface displays "Flash Error", Explanation Abnormal flash chip;
3) Interface display "Wireless Error",Description wireless chip anomalies.
9