Minib NU1, NU2, NW340, NW170, NP1 Installation Manual

...
CONTROL, ACCESSORIES,
INSTALLATION MANUALS
ABOUT US
ABOUT THE COMPANY
MINIB,a.s. is a Czech business through and through, and it ranks among the leading manufacturers of convectors in the Czech Repub­lic. It currently exports to thirty countries in Europe, Asia, Australia, and America.
Since 1999, MINIB has been systematically innovating its producti­on technology and its products and has invested considerable sums in proprietary development and design, with the goal of offering our customers solutions that are mature both from the technical and es­thetic points of view.
MINIB's business is economically soand and the company consis­tently turns a profi t. This allows us to invest in R&D, technology, and above all, human capital, so as to ensure our long-term prosperity.
ABOUT THE MANUFACTURING PROCESS
The manufacturing facility is located in Býkev near Mělník and has excellent transport connections. It is furnished with state-of-the-art production technology. Most manufacturing operations are carried out on CNC machines, which allows us to accommodate even the most sophisticated wishes of our exacting customers.
In response to individual calls for customization, we are able to crea­te a wide variety of non-standard, one-of-a-kind products that satisfy specifi c needs.
All products are made from high-grade material with a useful life of many years, which is why we offer a 10-year warranty on heat ex­changers and our stainless-steel convector vats.
MINIB holds an ISO 9001:2008 certifi cate in addition to numerous uti­lity models and patents.
The entire range of products is submitted to testing in the indepen­dent, accredited test chamber of HEATEST, s.r.o. pursuant to the Eu­ropean Standard EN 442-2, which is why we are able to guarantee the advertised heating and cooling output.
ABOUT THE PRODUCTS
MINIB's production portfolio consists of over 70 convector types. Customers can thus choose the right convector for any interior.
The main advantage of convectors is that they are effi cient, modern, economical, and esthetic heaters suitable for both dry and humid environments. Signifi cant power savings are achieved thanks to low water requirements for the immediate heating or cooling of a gi­ven area. This leads to low consumption of electricity required for its heating. In addition to water and energy savings, a great heating and cooling dynamics is also important. The space saving design is another important feature of these products. Our convectors do not disturb interior esthetics, have a modern design, and - last but not least - are safe thanks to their 12V power supply.
The product range comprises various types of convectors:
FLOOR convectors without fans that work on the natural con-
vection principle. Convectors with fans utilize the principle of forced convection.
FREE STANDING AND WALL MOUNTED convectors with and
without fans are also available. Heating benches with gra­nite and wooden top panels are available for humid environ­ments (swimming pools, bathrooms).
DESIGN convectors are a unique patent series that use both
the convection and heat radiation principle for heating. These convectors have aluminum composite front panels available in a number of modern designs from smooth glass with various colors or from glass with sand blasted deco­rations. The company also offers granite front panels.
MINIB can satisfy any individual, non-standard requirements of its customers such as angular or arc-shaped convectors with various connections and tailor them to their demands. MINIB emphasizes high user comfort. All products place low demands on installation and maintenance.
Numerous accessories are available for individual convector types. MINIB products have won a number of national and foreign awards.
34
1. UNIT DESCRIPTION
These are wall mounted unit types NU1, NU2, NW 170, NW340, NP1, NP2 (based on the natural convection principle) and NK1, NK2, which are equipped with fans. Since the units fully use the laws of physics in the area of thermodynamics, they represent the most effi cient means of interior heating.
BENEFITS OF WALL MOUNTED CONVECTORS:
high output, silent operation and very low noise of fan units, light weight compared to other heating units with similar output using the radiation principle, low hot water consumption, short response time, design, minimal operation and maintenance requirements, the small installation space is a great advantage of these units. You will appreciate this, particularly in situations when the units are used
during interior reconstruction and for the replacement of old heating units, even in places where suffi cient heating output needs to be main­tained.
2. PACKAGE CONTENT
Individual positions in the table correspond to Figure No. 1, see following page.
PACKAGE CONTENT Position NK1 NK2 NU1 NU2 NW 170 NW 340 NP1 NP2
Convector
Plastic cover 1 2 2 2 2 2 2 2 2
Grille 2 1 1 1 1 1 1 1 1
Convector body 3 1 1 1 1 1 1 1 1
Load bearing piece 4
11111111
Exchanger 5
11111111
Exchanger holder + screw 6, 7, 8
22222222
Adjustment screw 9 1 1 1 1 1 1 1 1
Fan 17 1-2 1-2 - - - - - -
EB control unit 18 1 1 - - - - - -
O-RING 18X2 19 1 1 1 1 1 1 1 1
Accessories
Heimeier AT 15 V_exakt valve
1011111111
Thermostatic head
1111111111
Screw fi tting - straight
12----1111
Screw fi tting - angular
121111- - --
Hose G1/2“ – 65mm
131- - -1111
Hose G1/2“ – 41 mm
13-111----
Sealing KLIGERSIL C4400
1444444444
Dowel No. 10
1522222222
Wood screw 6x50
1622222222
installation manuals - wall mounted convectors
35
3. TECHNICAL PARAMETERS
Figure 1: COMPONENTS OF WALL MOUNTED CONVECTOR
usage: dry or wet premises according to specifi cations, maximum operating pressure: 1.0 MPa, maximum operating temperature: 95 °C, operating medium: water. The use of other media is prohibited.
Water may not be mixed with other substances, such as non-free­ze liquids!
environment: interiors with temperatures between +5°C and
+40°C.
1. PLASTIC COVER - intended for grille attachment to the convector body.
2. CONVECTOR GRILLE - design element protecting the convector outlet. Must not be covered !!!
3. EXTERNAL CONVECTOR BODY - aluminum body of the convector.
4. CONVECTOR BEARING PIECE - attachment piece of the wall moun­ted convector and load bearing piece of the convector body.
5. EXCHANGER - copper pipes with pressed-on aluminum fi ns through which the heating water fl ows.
6. FIXED EXCHANGER HOLDER - intended to set the exchanger po­sition.
7. EXCHANGER HOLDER - intended for exchanger attachment.
8. EXCHANGER HOLDER SCREW - intended for exchanger holder fi t­ting.
9. ADJUSTMENT SCREW - intended for adjustment of horizontal posi­tion of the convector body.
10. THERMOSTATIC VALVE - intended for fl ow control.
11. THERMOSTATIC HEAD - intended for manual regulation.
12. SCREW FITTING - a valve that controls / adjusts heating water fl ow.
13. HOSE – the bellows hose is a stainless hose intended for fi tting connection to the convector exchanger.
14. SEALING - seals joints between valves, hoses, and exchangers (KLEGERSIL C4400). MINIB, s.r.o. recommends this sealing as an optimum sealing solution, as other materials (rubber, NBR, silicon) do not have suffi cient tightness upon suffi cient tightening and be­cause they are deformed by tightening forces.
15. DOWEL - for screw fi xing in the wall.
16. WOOD SCREW - fi xing of the convector bearing piece
17. O-RING - sealing between heat exchanger and thermostatic valve.
18. EB CONTROL UNIT - fan motor control unit.
19. FAN - intended for forced convection.
wall mounted convectors - installation manuals
36
NK1 NK2 NU1 NU2 NW 170 NW 340 NP1 NP2
A7985909090909090
B L-185 L-185 L-357 L-357 L-357 L-357 L-357 L-357
C 137 163 135 135 135 135 135 135
D
50 50 50 50 50 50 50 50
E
41 46 41 41 41 41 31 31
F
-30 5 -55 -55 0 0 -10 -10
G
105 92 90 260 87 257 92 177
H
40 50 45 45 35 35 42 128
I
3535------
J
130 130 - - - - - -
4. BEFORE INSTALLATION
Use the catalogue to choose a suitable convector - see paragraph 4.1. Select correct convector position and placement - see paragraph 4.2.
4.1 Suitable Convector Type
Decide whether the convector will act as the main source of heat, an additional heating element or a thermal barrier.
As the main source of heat in your apartment / room, the convector should suffi ciently cover the entire thermal loss of the room. There­fore, choose a heating unit with a capacity that is higher than the thermal loss of your apartment, room, or other premises.
All wall mounted convectors are intended for a dry environment. This means an environment where the average annual humidity does not exceed 85%. In terms of convector selection, a dry environment is generally any environment where no precipitation of vapor occurs in the convector unit.
4.2 Convector Position
A MINIB Wall mounted convector is intended for installation on walls under windows or window sills. Install the convector approximate­ly 100 mm under the window frame. Observe the rule according to which the gap between the fl oor should be greater than 80 mm. Never cover the top grille - this will result in fl ow reduction and in a conside­rable decrease of the convector's output.
Installation dimensions (mm) for the installation of water pipes, cabling, and wall mounting
5. INSTALLATION
installation manuals - wall mounted convectors
Figure 2: The recommended distance of the convector from the bottom of the
window (window sill) is 100mm. The minimum distance from the fl oor must be 80mm.
Figure 3: 0 – is the top edge of the rear wall mounted side without covers and
grille.
Figure 4: Plan the position of the heating unit. Observe the dimensions speci-
fi ed in the installation table - see Table 2. Mark the water inlet/outlet, fi tting ho­les for the bearing piece of the convector, and electric connection (as appro­priate). Observe the principles specifi ed in paragraph 4.2 (convector position).
Figure 5: Drill the mounting holes. Install the pipes and power supply cable as
appropriate.
Figure 6: Insert dowels in holes.
37
wall mounted convectors - installation manuals
Figure 8: Align the bearing piece into a horizontal position and tighten the
fi xing screws.
Figure 9: Mount the exchanger using exchanger holders and screws.
Figure 10: Pull the cable through the grommet and connect the control unit
of the motors according to the "Controls" manual depending on the selected control type. Test the connection.
Figure 12: Attach the convector frame, grille, and covers.
Figure 13: Screw head onto thermostatic valve.
Figure 7: Turn the adjustment stoppers to middle position. Screw the bearing
plate to the dowels. Do not tighten the screws completely.
Figure 11: Connect fi ttings. Inlet – thermostatic valve. Outlet – screw fi tting.
The inlet is always at the bottom. Test the connection tightness.
38
6. CONNECTION OF FITTINGS
Connect the fi ttings with the supplied standard accessories. Connect individual inlet and outlet valves. The thermostatic valve
(standard supply) is connected to the water inlet to the convector for fl ow regulation. The screw fi tting is installed on the outlet pipe. Sealing must be used in all joints. Flow direction is from bottom to top.
Use the supplied fl exible stainless hoses for exchanger connection (bellows hose), which will later enable vertical exchanger tilting for the purpose of cleaning. Connect fi ttings according to Figure 14.
Stainless hoses are designed to withstand a maximum pressure of
1.0 MPa. Hoses must not be stretched, compressed, or otherwise deformed.
Media inlet: the thermostatic valve (standard supply) is connected to the water inlet.
Outlet (return pipe): the screw fi tting is always connected to the re­turn pipe.
8. OPTIONALES ACCESSORIES
Thermostatic valve - straight, ½” Thermostatic valve - angular, ½” Screw fi tting - straight, ½” Screw fi tting - angular, ½” Ball valve - straight, ½” Ivar thermostatic head Heimeier thermostatic head Bellows hose ½” - ½” 65 mm Bellows hose ½ - ½ 41 mm
7. UNIT DEAERATION
Deaerate the unit by opening the deaerating valve during the fi rst use. The deaerating valve is located near the water inlet on the heat ex­changer fi tting.
installation manuals - wall mounted convectors
Figure 15: Deaerating valve
Figure 14
Figure 14: Adjust the vertical position of the convector using the adjustment
screws at the bottom of the convector body.