mind alive Oasis Pro Operator's Manual

[
OPERATORS MANUAL]
Usage and care of your CES device
Version 1, Revision 6
May 2019
Do not use if you have a cardiac pacemaker. The electrical signals may
cause the pacer to malfunction, leading to serious injury or death.
Do not use while driving or operating hazardous machinery. Do not place ear clips or electrodes over skin lesions, new scars, cuts,
eruptions or sunburn. All persons who:
a) suffer from any mental disorder or psychiatric illness, b) are currently using any drugs (prescription or recreational), c) are under the influence of alcohol, d) have serious head injuries, epilepsy, brain tumors, or strokes,
should not use the Oasis Pro unless under the supervision of a qualified health care provider.
The Oasis Pro delivers electrical current through the body and
should be used with care.
NOTICE TO HEALTHCARE PROVIDERS
It is the responsibility of the health care provider to complete a proper intake. Mind Alive Inc., its employees, suppliers and distributors are exempt from any liability in damages resulting from a seizure or psychiatric condition that may occur from prescribing this device.
THE OASIS PRO I S NOT RECOGNIZED AS A T REATMENT OR
CURE OF ANY MEDICAL CONDITION OR DISABILITY. HOWEVER,
RESEARCH SUGGESTS THA T THE OASIS PR O IS A N EFFECTIVE
RELAXATIO N AND ME DITATION TOOL.
All rights reserved
Reproduction in whole or in part is forbidden without
the express written consent of Mind Alive Inc.
© 2019 Mind Alive Inc.
Edmonton, Alberta, Canada
TABLE OF CONTENTS
WARNINGS ............................................................. INSIDE FRONT COVER
NOTICE TO HEALTHCARE PROVIDERS ...................................... INSIDE FRONT COVER
INTRODUCTION ............................................................................................. 1
COMPONENT LIST ............................................................................................................ 1
OPTIONAL ACCESSORIES ................................................................................................. 1
ABOUT CES....................................................................................................... 2
ABOUT MICROCURRENT ELECTRO THERAPY (MET) ................................................ 3
OPERATING INSTRUCTIONS ..................................................................... 4
POWER .............................................................................................................................. 4
TURN ON/TURN OFF ...................................................................................................... 4
ENDING A SESSION........................................................................................................... 4
PLACEMENT OF ELECTRODES ........................................................................................ 4
BATTERY LEVEL ............................................................................................................... 5
SELECTING A SESSION ..................................................................................................... 5
CONNECTION TEST .......................................................................................................... 6
ADJUSTING INTENSITY .................................................................................................... 7
SAVING PREFERENCES .................................................................................................... 7
QUICK START .................................................................................................. 8
OASIS PRO SESSIONS.................................................................................... 9
ICON DESCRIPTIONS ................................................................................. 11
ADDITIONAL FUNCTIONS ....................................................................... 13
MICROCURRENT ELECTRICAL THERAPY (MET) ..................................................... 13
TRANSCRANIAL DC STIMULATION (TDCS) .............................................................. 14
USER DESIGNED SESSIONS .......................................................................................... 14
TABLE OF CONTENTS
WARRANTY AND CARE ............................................................................ 15
RETURNING FOR REPAIRS ........................................................................................... 16
FOR UNITED STATES AND INTERNATIONAL CUSTOMERS ....................................... 16
DISCLAIMER OF LIABILITY ........................................................................................... 17
CARE AND MAINTENANCE ........................................................................................... 17
TROUBLESHOOTING ................................................................................. 18
[1]
INTRODUCTION
You have purchased the most innovative, high-quality Cranio-Electro
Stimulation (CES) device available on the market today. We are
confident you will find that using the Oasis Pro will improve your quality of life and increase relaxation.
The Oasis Pro may be used while you are sitting, lying down or engaged in quiet, non-hazardous activity (eg. light housework, reading, listening to the radio, watching TV, or on a relaxing walk).
Additional accessories are available for the Oasis Pro to add Microcurrent Electro Therapy (MET) or Transcranial DC Stimulation (tDCS) functionality. For more information please see the Additional Functions section on page 13.
In order to obtain maximum enjoyment and benefits from your Oasis Pro, please read this operator's manual thoroughly.
COMPONENT LIST
Oasis Pro – Serial Number ____________________________________________ Stimulus cable with ear clips Storage Bag 9-Volt Alkaline Battery Oasis Pro Operator’s Manual
OP TIO NAL AC CES SOR IES
MET Kit MET Probe Kit tDCS Kit DAVID Session Editor
[2]
ABOUT CES
As far back as the first century, the Greeks and Romans used the electric
ray, a variety of the “Torpedo Fish” for electrical stimulation. The electric
ray was used well into the 19th century, even after the invention of electronic stimulation devices. First century writings record placing a live torpedo fish under the feet of a person suffering from gout to ease
the pain. There are also reports of placing these fish on people’s
foreheads to treat headaches.
Current interest in CES was initiated by Robinovitch, who in 1914 made the first claim for electrical treatment of insomnia. In 1958, the book Electro-Sleep reflected the first serious works on CES. This book inspired research in Europe and in Eastern Bloc countries, as well as in South America, Asia and finally the US. Because the CES equipment used was bulky, inconvenient, and unreliable, CES, like the electric eel, was abandoned in favor of drug therapies.
With the invention of the transistor in the 1960s, small, low-power and reliable CES devices were developed. By 1975 several companies in the US and Europe were manufacturing CES devices for public use. During this time, research on CES was quite active and scientific papers were published.
Most studies to date have shown CES as a reliable method to reduce anxiety and improve cognition in recovering alcoholics. Additional studies have shown CES to be an effective tool in reducing anxiety and improving IQ.
Research to date is quite vague on the effects of using CES at various frequencies, citing both low and high frequencies can be effective for improving learning and reducing anxiety. Many people, who have used CES along with AVE, have reported that they experienced deeper relaxation for prolonged periods of time. In addition to enhancing
[3]
ABOUT CES
entrainment, CES increases neurotransmitter production. These neurotransmitters are necessary for information processing, memory, energy level and physical well-being. When our neurotransmitters and endorphins are not produced to necessary levels, it may lead to destructive behaviors and/or the abuse of substances as a substitute for that “natural high”.
ABOUT MICR OCURREN T E LECTRO THERAPY (ME T)
Although electromedicine has been in existence for well over a thousand years, developments in electronics and new research have seen this technology grow at a terrific rate in recent years. MET (also known as Micro-TENS) is very different than traditional TENS because MET produces some of its benefits on a cellular level. MET may replace TENS for pain applications as it has longer lasting effects.
The concept of MET is based, in part, on Arndt’s Law, which states that
weak stimuli excite physiological activity, whereas medium-strength stimuli will encourage activity and strong stimuli will suppress activity.
It is believed that MET delivered at around 500 micro-amps and randomly produced in the 0.5 to 3 Hz range may be most effective for treating pain. The Oasis Pro uses sting reduction and randomization techniques (patent pending) to improve the user experience and effectiveness of MET.
[4]
OPERATING INSTRUCTIONS
POWER
The Oasis Pro is powered by a 9-volt alkaline or rechargeable battery. To install the battery, slide the cover off of the battery compartment on the back of the unit. Insert a 9-volt battery as indicated on the diagram in the battery compartment. Slide the cover back into place. An alkaline 9-volt battery will provide approximately 25-30 hours of operation.
TURN ON/TURN OFF
Press and hold the power button ( ) until the power LED turns on. The graph will display the battery level when you first turn on the unit (see page 5). If no session is selected within two (2) minutes, the Oasis Pro will turn off.
To turn off the Oasis Pro at any time, press and hold the power button ( ) until the unit shuts off. This may take up to one (1) second if a session is running.
ENDING A SESSION
All sessions end with Soft Off™: a gradual reduction of the CES stimulus. After Soft Off™ the unit will power off. To end a session early, press and
release the power button ( ). The graph will scroll from 8 to 1 to confirm that Soft Off™ is in progress.
PLACEMENT OF ELE CTRODES
Remove glasses, earrings or any other objects near the ears that might interfere with the ear clips. Plug in the stimulus cable into the CES output jack ( ). To ensure a better electrical connection, wet the earlobe using tap water, saliva or a tiny amount of conductive gel before attaching the ear clips. Attach the black clip to the left ear and the red clip to the right ear.
Loading...
+ 16 hidden pages